ASTM E342-2004 Standard Test Method for Determination of Chromium Oxide in Chrome Ores by Permanganate Titrimetry《用高锰酸钾滴定法测定铬矿石中氧化铬的标准试验方法》.pdf
《ASTM E342-2004 Standard Test Method for Determination of Chromium Oxide in Chrome Ores by Permanganate Titrimetry《用高锰酸钾滴定法测定铬矿石中氧化铬的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E342-2004 Standard Test Method for Determination of Chromium Oxide in Chrome Ores by Permanganate Titrimetry《用高锰酸钾滴定法测定铬矿石中氧化铬的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 342 04Standard Test Method forDetermination of Chromium Oxide in Chrome Ores byPermanganate Titrimetry1This standard is issued under the fixed designation E 342; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the ye
2、ar of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of chromiumoxide (Cr2O3) in chrome ores in the concentration range fr
3、om25 to 60 %.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.
4、 Referenced Documents2.1 ASTM Standards:2D 1193 Specification for Reagent WaterE 50 Practices for Apparatus, Reagents, and Safety Precau-tions for Chemical Analysis of Metals, Ores, and RelatedMaterialsE 135 Terminology Relating to Analytical Chemistry forMetals, Ores, and Related MaterialsE 276 Tes
5、t Method for Particle Size or Screen Analysis atNo. 4 (4.75-mm) Sieve and Finer for Metal-Bearing Oresand Related MaterialsE 882 Guide for Accountability and Quality Control in theChemical Analysis Laboratory3. Terminology3.1 DefinitionsFor definitions of terms used in this testmethod, refer to Term
6、inology E 135.4. Summary of Test Method4.1 The sample is decomposed by fusion with sodiumperoxide. After leaching in water and boiling to decomposeperoxides, the solution is acidified with nitric and sulfuricacids. Residual chromium is oxidized to chromate with silvernitrate, potassium permanganate,
7、 and peroxydisulfate. Theexcess of permanganate is destroyed by the addition of sodiumchloride. After cooling, the chromate is reduced by the additionof a measured excess of a ferrous ammonium sulfate, and theexcess titrated with a standard permanganate solution.5. Significance and Use5.1 This test
8、method is intended to be used for compliancewith compositional specifications for chromium oxide content.It is assumed that all who use these procedures will be trainedanalysts capable of performing common laboratory proceduresskillfully and safely. It is expected that work will be performedin a pro
9、perly equipped laboratory and that proper wastedisposal procedures will be followed. Appropriate qualitycontrol practices must be followed such as those described inGuide E 882.6. Interferences6.1 None of the elements normally found in chrome oresinterfere with this test method.7. Reagents and Mater
10、ials7.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents conform to the specifications of the Committee onAnalytical Reagents of the American Chemical Society wheresuch specifications are available3. Other grades may be
11、used,provided it is first ascertained that the reagent is of sufficientlyhigh purity to permit its use without lessening the accuracy ofthe determination.7.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean reagent water as definedby Type I of Specification D
12、 1193.7.3 Ammonium Peroxydisulfate Solution (250 g/L)Dissolve 25 g of ammonium persulfate (ammonium peroxy-disulfate) (NH4)2S2O8) in water, and dilute to 100 mL.Prepare fresh as needed.1This test method is under the jurisdiction of ASTM Committee E01 onAnalytical Chemistry for Metals, Ores, and Rela
13、ted Materials and is the directresponsibility of Subcommittee E01.02 on Ores, Concentrates, and Related Metal-lurgical Materials.Current edition approved May 1, 2004. Published June 2004. Originallyapproved in 1967. Last previous edition approved in 1999 as E 342 99.2For referenced ASTM standards, v
14、isit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Reagent Chemical, American Chemical Society Specifications, AmericanChemical Society, Washing
15、ton, DC. For suggestions on the testing of reagents notlisted by the American Chemical Society, see Analar Standards for LaboratoryChemicals, BDH Ltd., Poole Dorset, U. K., and the United States Pharmacopeiaand National Formulary, U.S. Pharmaceutical Convention, Inc., (USPC), Rockville,MD.1Copyright
16、 ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7.4 Ferrous Ammonium Sulfate, Standard Solution (0.2N)Dissolve 78.4 g of ferrous ammonium sulfate(FeSO4(NH4)2SO46H2O) in 1 L of cool H2SO4(5+95). As theferrous ammonium sulfate solution gradually
17、 weakens inreducing power, it is necessary to standardize it daily, or at thesame time that the chrome ore is analyzed. To standardize,transfer 100 mL of FeSO4(NH4)2SO46H2O to a 600-mLbeaker, dilute to 300 mL with cold H2SO4(5+95), add 2 mL ofH3PO4and 2 drops of ortho-phenanthroline ferrous sulfate(
18、Ferroin). Titrate immediately with 0.2 N KMnO4solution to afaint, permanent pink color.7.5 Ferrous Sulfate Solution (0.025 M)Dissolve 6.95 g offerrous sulfate (FeSO47H2O) in 500 mL of water and dilute to1L.7.6 Nitric Acid (sp gr 1.42)Concentrated nitric acid(HNO3).7.7 Ortho-Phenanthroline Ferrous Su
19、lfate Indicator Solu-tion (0.025 M)Dissolve 1.485 g of 1,10-phenanthrolinemonohydrate in 100 mL of ferrous sulfate solution (FeSO47H2O).7.8 Phosphoric Acid (sp gr 1.69)Concentrated phosphoricacid (H3PO4).7.9 Potassium Permanganate Solution (20 g/L)Dissolve20 g of potassium permanganate (KMnO4) in wa
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME3422004STANDARDTESTMETHODFORDETERMINATIONOFCHROMIUMOXIDEINCHROMEORESBYPERMANGANATETITRIMETRY 高锰酸钾

链接地址:http://www.mydoc123.com/p-527453.html