1、Designation: E 341 08Standard Practice forMeasuring Plasma Arc Gas Enthalpy by Energy Balance1This standard is issued under the fixed designation E 341; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A n
2、umber in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the measurement of total gasenthalpy of an electric-arc-heated gas stream by means of anoverall system energy balan
3、ce. This is sometimes referred to asa bulk enthalpy and represents an average energy content of thetest stream which may differ from local values in the teststream.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the
4、 user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Summary of Test Method2.1 A measure of the total or stagnation gas enthalpy ofplasma-arc heated gases (nonreacting) is based upon thefollowing measu
5、rements:2.1.1 Energy input to the plasma arc,2.1.2 Energy losses to the plasma arc hardware and coolingwater, and2.1.3 Gas mass flow.2.2 The gas enthalpy is determined numerically by dividingthe gas mass flow into the net power input to the plasma arc(power to plasma arc minus the energy losses).2.3
6、 The technique for performing the overall energy balanceis illustrated schematically in Fig. 1. The control volume forthe energy balance can be represented by the entire envelope ofthis drawing. Gas enters at an initial temperature, or enthalpy,and emerges at a higher enthalpy. Water or other coolan
7、t entersthe control volume at an initial temperature and emerges at ahigher temperature. Across the arc, electrical energy is dissi-pated by virtue of the resistance and current in the arc itself. Aheat balance of the system requires that the energy gained bythe gas must be defined by the difference
8、 between the incomingenergy (electrical input) and total coolant and external losses.This is a direct application of the First Law of Thermodynam-ics and, for the particular control volume cited here, can bewritten as follows:Energy In 2 Energy Out 5 Energy to Gas (1)EI2 QCR2(i 5 1nWH2 OiCpDT02DT1!H
9、2Oi2(j 5 1pMjHj5 WgHg2 Hin!where:Cp= water, specific heat,E = plasma arc voltage,Hg= exhaust gas enthalpy,Hin= inlet gas enthalpy,Hj= heat of vaporization corresponding to the ma-terial Mj,I = plasma arc current,Mj= mass loss rate of electrode insulator, interiormetal surface, etc.QCR= energy convec
10、ted and radiated from externalsurface of plasma generator,DT0H2O= T02 T01= water temperature rise duringplasma arc operation,DT1H2O= T2T1= water temperature rise before plasmaarc operation,T02= water exhaust temperature during plasma arcoperation,T01= inlet water temperature during plasma arc op-era
11、tion,T2= water exhaust temperature before plasma arcoperation,T1= inlet water temperature before plasma arc op-eration,Wg= gas flow rate,WH2O= mass flow rate of coolant water, andEI= average of the product of voltage, E, andcurrent, I.2.4 An examination of Eq 1 shows that, in order to obtain anevalu
12、ation of the energy content of the plasma for a specifiedset of operating conditions, measurements must be made of thevoltage and current, the mass-flow rate and temperature rise ofthe coolant, the mass-flow rate and inlet ambient temperatureof the test gas, and the external surface temperature andh
13、ousing of the arc chamber. For all practical purposes, theexternal surface temperature of the water-cooled plasma arc isminimum. Consequently, it will be assumed throughout thisdiscussion that negligible energy (compared to the inputenergy) is lost from the external plasma generator surface by1This
14、practice is under the jurisdiction of ASTM Committee E21 on SpaceSimulation and Applications of Space Technology and is the direct responsibility ofSubcommittee E21.08 on Thermal Protection.Current edition approved May 1, 2008. Published May 2008. Originallyapproved in 1968. Last previous edition ap
15、proved in 2002 as E 341 96 (2002).1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.convective or radiative mechanisms and that the internal loss ofelectrode or plasma generator material is small compared withthe energy input. In addit
16、ion, as some plasma generators utilizemagnetic fields in their design, the magnetic field coil electricalpower and ohmic-heating dissipation should be included in theover-all heat balance. Precautions should be taken to assurethat only a negligible portion of magnetic energy is beingdissipated in ha
17、rdware not within the heat balance circuit. Forthe purposes of this discussion, the magnetic field power inputand loss aspects have been omitted because of their uniqueapplicability to specific plasma generator designs.2.5 The energy balance is given by Eq 2 when these factorsare taken into account:
18、EI2(i 5 1nWH2OiCpDT02DT1!H2Oi5 WgHg2 Hin! (2)The exhaust enthalpy, Hg, of the effluent as defined by Eq 1and 2 is a measure of the average total (stagnation) enthalpy atthe nozzle exit plane of the plasma-arc heater. This enthalpydoes not necessarily apply to the plasma downstream of thenozzle exit
19、plane.3. Significance and Use3.1 The purpose of this practice is to measure the total orstagnation gas enthalpy of a plasma-arc gas stream in whichnonreactive gases are heated by passage through an electricaldischarge device during calibration tests of the system.3.2 The plasma arc represents one he
20、at source for determin-ing the performance of high temperature materials undersimulated hyperthermal conditions. As such the total or stag-nation enthalpy is one of the important parameters for corre-lating the behavior of ablation materials.3.3 The most direct method for obtaining a measure of tota
21、lenthalpy, and one which can be performed simultaneously witheach material test, if desired, is to perform an energy balanceon the arc chamber. In addition, in making the energy balance,accurate measurements are needed since the efficiencies ofsome plasma generators are low (as low as 15 to 20 % or
22、lessin which case the enthalpy depends upon the difference of twoquantities of nearly equal magnitude). Therefore, the accuracyof the measurements of the primary variables must be high, allenergy losses must be correctly taken into account, andsteady-state conditions must exist both in plasma perfor
23、manceand fluid flow.3.4 In particular it is noted that total enthalpy as determinedby the energy balance technique is most useful if the plasmagenerator design minimizes coring effects. If nonuniformityexists the enthalpy determined by energy balance gives onlythe average for the entire plasma strea
24、m, whereas the localenthalpy experienced by a model in the core of the stream maybe much higher. More precise methods are needed to measurelocal variations in total enthalpy.4. Apparatus4.1 GeneralThe apparatus shall consist of the plasma-arcfacility and the necessary instrumentation to measure thep
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME3412008781STANDARDPRACTICEFORMEASURINGPLASMAARCGASENTHALPYBYENERGYBALANCE 能量 平衡 测量 等离子体 电弧 气体 标准

链接地址:http://www.mydoc123.com/p-527451.html