ASTM D7636 D7636M-2011 6250 Standard Practice for Sampling and Analysis of Modified Bitumen Roof Systems《改性沥青屋面系统的抽样和分析标准操作规程》.pdf
《ASTM D7636 D7636M-2011 6250 Standard Practice for Sampling and Analysis of Modified Bitumen Roof Systems《改性沥青屋面系统的抽样和分析标准操作规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7636 D7636M-2011 6250 Standard Practice for Sampling and Analysis of Modified Bitumen Roof Systems《改性沥青屋面系统的抽样和分析标准操作规程》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7636/D7636M 11Standard Practice forSampling and Analysis of Modified Bitumen Roof Systems1This standard is issued under the fixed designation D7636/D7636M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the year of l
2、ast revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice is for removing specimens from existingmodified bitumen roof membranes for visual assessment andevaluatio
3、n for abnormalities in the membrane. The roof mem-brane consists of one or more plies/sheet materials in which atleast one ply is a modified bitumen (MB) sheet, and which isinstalled with one or more of the following methods: hotasphalt, heat welding (open flame torching or heated air), coldadhesive
4、, or self-adhesive. The roof membrane may consist ofone or more plies of the following:1.1.1 SBS (styrene-butadiene-styrene), APP (attactic poly-propylene), or other polymer, modified bitumen sheet materi-als.1.1.2 An exposed modified bitumen sheet material, that is, amodified cap sheet, covering mu
5、ltiple layers of built-up roofing(BUR) plies.1.1.3 Any adhesive or bitumen component used to installthe roof membrane.1.2 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsy
6、stem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.3 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for in
7、formation onlyand are not considered standard.2. Referenced Documents2.1 ASTM Standards:2D1079 Terminology Relating to Roofing and Waterproofing3. Terminology3.1 DefinitionsFor definitions of terms used in this prac-tice, refer to Terminology D1079.3.2 Definitions of Terms Specific to This Standard:
8、3.2.1 hybrid membrane system, nMB/BUR roof mem-brane consisting of a modified bitumen cap sheet with one ormore layers of underlying BUR.3.2.2 ply or sheet material, na single layer of the modifiedbitumen roof membrane.4. Sampling4.1 Unless otherwise specified, for each abnormal roof areatake at lea
9、st one specimen from the area that exhibits anabnormality plus one “control” specimen. The control speci-men should have no obvious abnormalities and should be takenin close proximity to the sampled problem area.4.2 Additional specimens in which abnormalities are exhib-ited in the membrane may be ta
10、ken to determine the extent ofthe affected area.5. Test Specimen5.1 As a minimum, the roof membrane specimens should betaken down to the top surface of the membrane substrate.Sampling down to the level of the roof deck may be necessaryto better determine the cause and extent of any abnormality.5.2 T
11、he recommended minimum specimen size is 305 by305 mm 12 by 12 in. or 100 by 1120 mm 4 by 44 in.,depending on the nature of the potential membrane problem. Ifthe membrane is a hybrid BUR/MB, the 100 by 1120 mm 4 by44 in. specimen size, cutting across the width of the cap sheet,is recommended.5.2.1 Th
12、e specimen size and shape may be adjusted, onceinitial sampling has occurred, to adequately assess the nature ofany problem.6. Significance and Use6.1 This practice is for removing specimens from existingmodified bitumen roof membranes for visual assessment andevaluation for abnormalities in the mem
13、brane.6.2 This practice is not intended for roofs under construc-tion.1This practice is under the jurisdiction ofASTM Committee D08 on Roofing andWaterproofing and is the direct responsibility of Subcommittee D08.20 on RoofingMembrane Systems.Current edition approved July 1, 2011. Published July 201
14、1. DOI: 10.1520/D7636_D7636M-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD7636D7636M20116250STANDARDPRACTICEFORSAMPLINGANDANALYSISOFMODIFIEDBITUMENROOFSYSTEMS 改性沥青 屋面 系统

链接地址:http://www.mydoc123.com/p-525995.html