ASTM D7090-2004 Standard Test Method for Purity of Isophorone by Capillary Gas Chromatography《用毛细气相色谱法测定异佛尔酮纯度的标准试验方法》.pdf
《ASTM D7090-2004 Standard Test Method for Purity of Isophorone by Capillary Gas Chromatography《用毛细气相色谱法测定异佛尔酮纯度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7090-2004 Standard Test Method for Purity of Isophorone by Capillary Gas Chromatography《用毛细气相色谱法测定异佛尔酮纯度的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 7090 04Standard Test Method forPurity of Isophorone by Capillary Gas Chromatography1This standard is issued under the fixed designation D 7090; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisio
2、n. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the purityof isophorone. This method also determines the impurities ofthe material i
3、n concentration level less than 0.5 mass %, whichmay include mesityl oxide (MSO), mesityl oxide-isomer,mesitylene, trimethyl cyclohexenone (TMCH), phorone,phorone-isomer, xylitone, and tetralone.1.2 Water cannot be determined by this test method andshall be measured by other appropriate ASTM procedu
4、re. Theresult is used to normalize the chromatographic data deter-mined by this test method.1.3 For purposes of determining conformance of an ob-served or a calculated value using this test method to relevantspecifications, test result(s) shall be rounded off “to the nearestunit” in the last right-h
5、and digit used in expressing thespecification limit, in accordance with the rounding - offmethod of Practice E 29.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate s
6、afety and health practices and to determine theapplicability of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1364 Test Method for Water in Volatile Solvents (KarlFischer Reagent Titration Method)E 29 Practice for Using Significant Digits in Test Data toDetermine C
7、onformance with SpecificationsE 300 Practice for Sampling Industrial Chemicals3. Summary of Test Method3.1 A representative specimen is introduced into a gaschromatograph with a bonded polyethylene glycol capillarycolumn using temperature programming and a flame ionizationdetector. The concentration
8、s of the sample components arecalculated from the integrated component peaks using internalstandardization technique with response factors. Water ismeasured in accordance with Test Method D 1364 and theresult is used to normalize the values obtained by gas chroma-tography.4. Significance and Use4.1
9、This test method determines the purity of isophorone, aswell as the concentration of various potential impurities,several of which are critical in the application of these solvents.5. Apparatus5.1 ChromatographAny gas chromatograph utilizing acapillary column and has the following characteristics (s
10、eeTable 1 for typical GC parameters):5.1.1 DetectorA flame ionization detector (FID) capableof continuous operation at a temperature equivalent to themaximum column temperature employed. The detector shallhave sufficient sensitivity to detect 0.001 mass % of impurity inthe specimen at a peak height
11、3 times the noise level.5.1.2 Columnfused silica capillary column with bondedpolyethylene (see Table 1 for details).5.1.3 Column Temperature Programmingthe chromato-graph shall be capable of reproducible linear temperatureprogramming.5.1.4 Sample Inlet Systemthe sample inlet system shall becapable o
12、f split injection, typically at a 100:1 split ratio.NOTE 1An autoinjector is recommended. Manual injection with asyringe is acceptable, however the observed precision may not apply.5.1.5 Integratormeans shall be provided for determiningthe area of the observed chromatographic peaks. This can bedone
13、by means of an electronic integrator or a computer basedchromatography data system. The integrator/computer systemshall have standard chromatographic software for determiningthe retention times and quantification of eluting peaks.5.1.6 Flow Controllerthe chromatograph shall beequipped with a constan
14、t flow device capable of maintainingthe carrier gas at a constant flow rate throughout the tempera-ture program.1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings, Materials, and Applications and is the direct responsibility ofSubcommittee D01.35 on Solven
15、ts, Plasticizers, and Chemical Intermediates.Current edition approved Nov. 1, 2004. Published November 2004.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the stan
16、dards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.1.7 Microsyringea microsyringe of appropriate capacityis required for injection of the specimen into the chromato-graph. Typically,a5Lsy
17、ringe is used.6. Reagents and Materials6.1 Purity of ReagentsReagent grade chemicals shall beused in the preparation of the calibration mixture.6.2 Calibration Mixture Components:6.2.1 Isophoronesolvent used in the preparation of thecalibration mixture, and shall be free of the components ofinterest
18、. If pure isophorone is not available, then isophoronecontaining relatively low concentration of the components ofinterest can be used, and the composition of the calibrationmixture corrected for components already present.(WarningIsophorone is a cancer suspect agent.)6.2.2 Mesitylene Oxide (MSO), 4
19、-methyl-3-pentene-2-onecalibration component.NOTE 2This chemical is commercially available typically as a mix-ture of two isomers with an MSO to MSO-isomer ratio of 10:1.6.2.3 Mesitylene Oxide Isomer (MSO-isomer), 4-methyl-4-pentene-2-onecalibration component.6.2.4 Mesitylene, 1,3,5-trimethyl benzen
20、ecalibration com-ponent.6.2.5 Trimethyl cyclohexenone (TMCH), 3,5,5-trimethyl-3-cyclohexen-1-one calibration component.6.2.6 Phorone, 2,6-dimethyl-hepta-3,5-diene-2-one cali-bration component.6.2.7 Phorone - Isomer, 4-6-dimethyl-hepta-3,5-diene-2-one calibration component.NOTE 3This chemical is not
21、commercially available but comes as animpurity of phorone.6.2.8 Tetralone, 3,4-dihydro-1-napthalenonecalibrationcomponent.6.2.9 Xylitone(s)optional calibration component.6.2.10 Decaneinternal standard.6.3 Carrier GasesHelium or hydrogen (minimum99.95 % purity). (WarningHelium and hydrogen are com-pr
22、essed gases under high pressure. Hydrogen is highly flam-mable.)7. Sampling7.1 Take samples of the material to be tested using proce-dures described in Practice E 300.8. Conditioning of Capillary Column8.1 Condition the gas chromatographic capillary columnfollowing the column supplier recommendation
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便