ASTM D5627-1994(2004) Standard Test Method for Water Extractable Residue from Particulate Ion-Exchange Resins《颗粒状离子交换树脂的水可萃取残留物的标准试验方法》.pdf
《ASTM D5627-1994(2004) Standard Test Method for Water Extractable Residue from Particulate Ion-Exchange Resins《颗粒状离子交换树脂的水可萃取残留物的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5627-1994(2004) Standard Test Method for Water Extractable Residue from Particulate Ion-Exchange Resins《颗粒状离子交换树脂的水可萃取残留物的标准试验方法》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5627 94 (Reapproved 2004)Standard Test Method forWater Extractable Residue from Particulate Ion-ExchangeResins1This standard is issued under the fixed designation D 5627; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisio
2、n, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the measurement of watersoluble extractable residue from particulate ion-excha
3、nge res-ins based on elevated temperature extraction and gravimetricdetermination of residue.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health prac
4、tices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1129 Terminology Relating to WaterD 1193 Specification for Reagent WaterD 2187 Test Methods for Physical and Chemical Propertiesof Particulate Ion-Exchange ResinsD 2687 Practice
5、s for Sampling Particulate Ion-ExchangeMaterialsD 2777 Practice for Determination of Precision and Bias ofApplicable Methods of Committee D19 on Water3. Terminology3.1 Definitions:3.1.1 For definitions of terms used in this test method, referto Terminology D 1129.4. Summary of Test Method4.1 A sampl
6、e of particulate ion exchange material is con-tacted with water at an elevated temperature. After a specifiedcontact time, the concentration of soluble material in theaqueous phase is measured gravimetrically after filtration.5. Significance and Use5.1 The presence of water extractables in ion-excha
7、ngeresins can cause fouling of other materials downstream andcontamination of process water. The quantity of water extract-ables is sometimes used as a specification to indicate resinquality, and typical values are 0.01 to 0.1 %.5.2 It is recognized that this test method may not remove allpotential
8、sloughage products and does not measure volatilecompounds. More extensive extraction and identification ofcompounds may be needed in specific cases.6. Interferences6.1 The hygroscopic nature of some extracted compoundscan make it difficult to obtain a constant weight. Otherextraction times and tempe
9、ratures may give results that are notcomparable to these.7. Apparatus7.1 Funnel, 60 mL with coarse frit.7.2 Filtration assembly.7.3 Glass fiber filters, without binder, pre-rinsed with wa-ter.37.4 Weighing vesselPlatinum, nickel, or aluminum maybe used so long as there is no attack by the sample and
10、 constantweight can be achieved.7.5 Water bath, for use at 60 6 1C.8. Reagents8.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the Ameri
11、can Chemical Society,where such specifications are available.4Other grades may be1This test method is under the jurisdiction of ASTM Committee D19 on Waterand is the direct responsibility of Subcommittee D19.08 on Membranes and IonExchange Materials.Current edition approved June 1, 2004. Published J
12、une 2004. Originallyapproved in 1994. Last previous edition approved in 1998 as D 5627 94 (1998).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Docum
13、ent Summary page onthe ASTM website.3Gelman Type A/E, Millipore Type AP40, Whatman GF/C, or equivalent, havebeen found suitable for this purpose.4Reagent Chemicals, American Chemical Society Specifications, AmericanChemical Society, Washington, DC. For suggestions on the testing of reagents notliste
14、d by the American Chemical Society, see Analar Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary, U.S. Pharmaceutical Convention, Inc. (USPC), Rockville,MD.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West
15、 Conshohocken, PA 19428-2959, United States.used, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.8.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean reagent
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD562719942004STANDARDTESTMETHODFORWATEREXTRACTABLERESIDUEFROMPARTICULATEIONEXCHANGERESINS 颗粒状 离子交换

链接地址:http://www.mydoc123.com/p-520278.html