ASTM D5438-2017 red 1645 Standard Practice for Collection of Floor Dust for Chemical Analysis《化学分析用地板尘埃采集标准实施规程》.pdf
《ASTM D5438-2017 red 1645 Standard Practice for Collection of Floor Dust for Chemical Analysis《化学分析用地板尘埃采集标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5438-2017 red 1645 Standard Practice for Collection of Floor Dust for Chemical Analysis《化学分析用地板尘埃采集标准实施规程》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5438 11D5438 17Standard Practice forCollection of Floor Dust for Chemical Analysis1This standard is issued under the fixed designation D5438; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers a procedure for the collection of a sample of dust from carpets and bare floors that can be analyzedfor lead, pe
3、sticides, or other chemical compounds and elements.1.2 This practice is applicable to a variety of carpeted and bare floor surfaces. It has been tested for level loop and plush pilecarpets and bare wood floors, specifically.1.3 This practice is not intended for the collection and evaluation of dust
4、for the presence of asbestos fibers.1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the
5、user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D422 Test Method for Particle-Size Analysis of Soils (Withdrawn 2016)3D1356 Terminology Relating to Sampling and
6、 Analysis of AtmospheresE1 Specification for ASTM Liquid-in-Glass ThermometersE337 Test Method for Measuring Humidity with a Psychrometer (the Measurement of Wet- and Dry-Bulb Temperatures)E1137/E1137M Specification for Industrial Platinum Resistance ThermometersE2251 Specification for Liquid-in-Gla
7、ss ASTM Thermometers with Low-Hazard Precision LiquidsF608 Test Method for Evaluation of Carpet Embedded Dirt Removal Effectiveness of Household/Commercial Vacuum Cleaners3. Terminology3.1 DefinitionsFor definitions of terms used in this practice, refer to Terminology D1356.3.1.1 carpet-embedded dus
8、tsoil and other particulate matter, approximately 5-m equivalent aerodynamic diameter and larger,embedded in carpet pile and normally removable by household vacuum cleaners.3.1.2 surface dustsoil and other particulate matter, approximately 5-m equivalent aerodynamic diameter and larger, adheringto f
9、loor surfaces and normally removable by household vacuum cleaners.4. Summary of Practice4.1 The sampling method described in this practice is taken from work published in Roberts,Roberts et alal. (1-3),4 andStamper,Stamper et alal. (4).4.2 Particulate matter is withdrawn from the carpet or bare floo
10、r by means of vacuum-induced suction which draws through asampling nozzle at a specific velocity and flow rate, and the particles are separated mechanically by a cyclone. The cyclone isdesigned to efficiently separate and collect particles approximately 5-m mean aerodynamic diameter and larger. Howe
11、ver, muchsmaller particles are also collected at unknown efficiencies. The sampling system allows for height, air flow, and suction1 This practice is under the jurisdiction of ASTM Committee D22 on Air Quality and is the direct responsibility of Subcommittee D22.05 on Indoor Air.Current edition appr
12、oved Aug. 15, 2011March 1, 2017. Published August 2011March 2017. Originally approved in 1993. Last previous edition approved in 20052011 asD5438 05.D5438 11. DOI: 10.1520/D5438-11.10.1520/D5438-17.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service a
13、t serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 The last approved version of this historical standard is referenced on www.astm.org.4 The boldface numbers in parentheses refer to the list of references at the
14、end of this standard.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that us
15、ers consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1adjustments to reproduce sy
16、stematically a specific air velocity for the removal of particulate matter from carpeted and bare floorsurfaces, so that these sampling conditions can be repeated.NOTE 1Side-by-side comparison of the HVS3 and a conventional upright vacuum cleaner revealed that both collected particles down to at lea
17、st 0.2m and that the HVS3 was more efficient at collecting particles smaller than 20 m than conventional vacuum cleaners (5). If desired, a fine-particle filtermay be added downstream of the cyclone to collect 99.9 % of particles above 0.2 m aerodynamic mean diameter.4.3 The particulate matter in th
18、e air stream is collected in a catch bottle attached to the bottom of the collection cyclone. Thiscatch bottle shall be capped for storage of the sample and transported to the laboratory for analysis.5. Significance and Use5.1 This practice may be used to collect dust from carpeted or bare floor sur
19、faces for gravimetric or chemical analysis. Thecollected sample is substantially unmodified by the sampling procedure.5.2 This practice provides for a reproducible dust removal rate from level loop and plush carpets, as well as bare floors. It hasthe ability to achieve relatively constant removal ef
20、ficiency at different loadings of surface dust.5.3 This practice also provides for the efficient capture of semivolatile organic chemicals associated with the dust. The testsystem can be fitted with special canisters downstream of the cyclone for the capture of specific semivolatile organic chemical
21、sthat may volatilize from the dust particles during collection.5.4 This practice does not describe procedures for evaluation of the safety of floor surfaces or the potential human exposure tocarpet dust. It is the users responsibility to evaluate the data collected by this practice and make such det
22、erminations in the lightof other available information.6. Interferences6.1 There are no known interferences to the determination of dust loadings covered by this practice.7. Apparatus7.1 Sampling Apparatus, which may be acquired commercially5 (as shown in Fig. 1) or constructed as follows:7.1.1 The
23、dimensions of the sampling apparatus (nozzle size, cyclone diameter, cyclone inlet diameter, etc.) are interdependent.The flow rate must produce a sufficient velocity both at the sampled surface and in the cyclone. The cyclone must have a cutdiameter of 5 m at the same velocity that will provide a h
24、orizontal velocity of 40 cm/s at 10 mm from the nozzle in the carpetmaterial, or 5 mm from the nozzle on bare floors. The fundamental principles of this device have been discussed in detail inRoberts,Roberts et alal. (1-3).7.1.2 NozzleThe edges and corners of the sampling nozzle shall be rounded to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD54382017RED1645STANDARDPRACTICEFORCOLLECTIONOFFLOORDUSTFORCHEMICALANALYSIS 化学分析 用地 尘埃 采集 标准 实施 规程

链接地址:http://www.mydoc123.com/p-519784.html