ASTM D5319-2012 Standard Specification for Glass-Fiber Reinforced Polyester Wall and Ceiling Panels《玻璃纤维增强聚酯墙板和天花板的标准规格》.pdf
《ASTM D5319-2012 Standard Specification for Glass-Fiber Reinforced Polyester Wall and Ceiling Panels《玻璃纤维增强聚酯墙板和天花板的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5319-2012 Standard Specification for Glass-Fiber Reinforced Polyester Wall and Ceiling Panels《玻璃纤维增强聚酯墙板和天花板的标准规格》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5319 12 An American National StandardStandard Specification forGlass-Fiber Reinforced Polyester Wall and Ceiling Panels1This standard is issued under the fixed designation D5319; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers the classification, materials ofconstruction, workmanship, physical r
3、equirements, and meth-ods of testing glass-fiber-reinforced polyester composite walland ceiling panels intended for use in light construction andsemi-structural applications.1.2 Supplementary information on chemical resistance, im-pact resistance, and installation practice are provided in Ap-pendix
4、X1.1.3 The classification of these composite panels into classesbased on relative response to a laboratory test shall not beconsidered a fire-hazard classification.1.4 Laboratory flammability tests (Test Methods E84 andD1929) applicable to this specification should be used tomeasure and describe the
5、 properties of materials, products, orassemblies in response to heat and flame under controlledlaboratory conditions and should not be used to describe orappraise the fire hazard or conditions. However, results may beused as elements of a fire risk assessment which takes intoaccount all of the facto
6、rs which are pertinent to an assessmentof the fire hazard of a particular end use.1.5 The intent of this specification is to define the class,grade, and general laminate properties of the composite walland ceiling liner panels in order to ensure a quality productwhich will perform in the intended ap
7、plication. This specifi-cation is not intended to restrict or limit technological changesaffecting performance when changes are agreed upon betweenthe purchaser and manufacturer.1.6 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are providedf
8、or information only.1.7 The text of this specification references notes andfootnotes that provide explanatory material. These notes andfootnotes (excluding those in Tables and Figures) shall not beconsidered as requirements of this specification.1.8 This standard does not purport to address all of t
9、hesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1There is no known ISO equivalent to this standard.2. Referenced
10、 Documents2.1 ASTM Standards:2D374 Test Methods for Thickness of Solid Electrical Insu-lationD618 Practice for Conditioning Plastics for TestingD883 Terminology Relating to PlasticsD1600 Terminology forAbbreviated Terms Relating to Plas-ticsD1929 Test Method for Determining Ignition Temperatureof Pl
11、asticsD2244 Practice for Calculation of Color Tolerances andColor Differences from Instrumentally Measured ColorCoordinatesD3029 Test Methods for Impact Resistance of Flat, RigidPlastic Specimens by Means of a Tup (Falling Weight)(Withdrawn 1995)3E84 Test Method for Surface Burning Characteristics o
12、fBuilding MaterialsE631 Terminology of Building Constructions3. Terminology3.1 GeneralDefinitions are in accordance with Terminolo-gies D883 and E631 and abbreviations with TerminologyD1600, unless otherwise indicated.3.2 Definitions of Terms Specific to This Standard:3.2.1 camber, nnon-linearity of
13、 the long axis of a panel.NOTE 2In the process of water jet, knife, saw, or rotary sheartrimming of a continuous panel, sidewards motion of the panel through thecutting medium can be induced by imbalances in the system. The resultingtrim cuts, although maintaining parallelism between the long sides,
14、 may1This specification is under the jurisdiction of ASTM Committee D20 onPlastics and is the direct responsibility of Subcommittee D20.24 on Plastic BuildingProducts.Current edition approved Oct. 1, 2012. Published November 2012. Originallyapproved in 1992. Last previous edition approved in 2008 as
15、 D5319 97(2008).DOI: 10.1520/D5319-12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved vers
16、ion of this historical standard is referenced onwww.astm.org.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1describe a continuous curve, rather than a straight line alo
17、ng the long axisof the panel. Imbalances in side-to-side cure rates or material distributionmay also produce this phenomenon. This curvature of the long axis maycreate problems with installation of the panel. Limits are placed on thedegree of non-linearity to minimize those problems.4. Classificatio
18、n4.1 The panels covered by this specification are divided intofour classifications based on relative response to the laboratoryflammability of Test Method E84.4.1.1 Class AFlame spread index 0 to 25, smoke devel-opment index of 450 or less.4.1.2 Class BFlame spread index 26 to 75, smoke devel-opment
19、 index of 450 or less.4.1.3 Class CFlame spread index 76 to 200, smokedevelopment index of 450 or less.4.1.4 Class DGeneral purpose, no flame spread or smokedevelopment indices.NOTE 3Refer to 1.3 on flammability testing and fire hazard classifi-cation.4.2 These classifications may be further subdivi
20、ded intogrades based on nominal thickness when tested in accordancewith 8.4:4.2.1 Grade 10.027 to 0.033 in. (0.69 to 0.84 mm); 0.030in. nominal (0.76 mm).4.2.2 Grade 20.036 to 0.044 in. (0.91 to 1.12 mm); 0.040in. nominal (1.02 mm).4.2.3 Grade 30.040 to 0.050 in. (1.02 to 1.27 mm); 0.045in. nominal
21、(1.14 mm).4.2.4 Grade 40.054 to 0.066 in. (1.37 to 1.68 mm); 0.060in. nominal (1.52 mm).4.2.5 Grade 50.067 to 0.083 in. (1.70 to 2.11 mm); 0.075in. nominal (1.91 mm).4.2.6 Grade 60.081 to 0.099 in. (2.06 to 2.51 mm); 0.090in. nominal (2.29 mm).4.2.7 Grade 70.108 to 0.132 in. (2.74 to 3.35 mm); 0.120
22、in. nominal (3.05 mm).4.3 Within the classification of grade and class of compositepanel described in this specification are commercial productswith the following variations as agreed upon between thepurchaser and manufacturer.4.3.1 Size (Length and Width)The nominal sizes availableare 23.75 in. (60
23、3.25 mm) to 120 in. (3048 mm) in width and47.75 in. (1212.85 mm) to 500 continuous feet of coil stock(152 m) in length.4.3.2 ThicknessThe nominal thicknesses available are0.0303 in. (0.77 mm) to 0.120 in. (3.05 mm).4.3.3 ColorRefer to manufacturers literature for therange of colored product availabl
24、e.4.3.4 SurfaceThe two most popular surfaces available aretextured and smooth.5. Materials5.1 The polyester resin used in the composite shall be athermosetting polyester resin with cross-linking monomerscomposed of polymeric esters in which the recurring estergroups are an integral part of the main
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD53192012STANDARDSPECIFICATIONFORGLASSFIBERREINFORCEDPOLYESTERWALLANDCEILINGPANELS 玻璃纤维 增强 聚酯 天花板

链接地址:http://www.mydoc123.com/p-519464.html