ASTM D4811-2006 Standard Specification for Nonvulcanized (Uncured) Rubber Sheet Used as Roof Flashing《作为屋顶防雨板用的非硫化橡胶薄板材的标准规范》.pdf
《ASTM D4811-2006 Standard Specification for Nonvulcanized (Uncured) Rubber Sheet Used as Roof Flashing《作为屋顶防雨板用的非硫化橡胶薄板材的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4811-2006 Standard Specification for Nonvulcanized (Uncured) Rubber Sheet Used as Roof Flashing《作为屋顶防雨板用的非硫化橡胶薄板材的标准规范》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4811 06Standard Specification forNonvulcanized (Uncured) Rubber Sheet Used as RoofFlashing1This standard is issued under the fixed designation D 4811; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers nonvulcanized (uncured) rub-ber sheet made of EPDM (ethylene-propylene-diene terpoly-mer) or CR
3、(polychloroprene) intended for use as watertightroof flashing exposed to the weather.1.2 The tests and property limits used to characterize theseflashing materials are specific for each classification and areminimum values to make the product fit for its intendedpurpose.1.3 SI units shall be used in
4、 referee decisions.1.4 In-place roof system design criteria, such as fire resis-tance, field seaming strength, material compatibility, and upliftresistance, among others, are beyond the scope of this speci-fication.1.5 The following precautionary caveat pertains to the testmethods portion only, Sect
5、ion 8, of this specification: Thisstandard may involve hazardous materials, operations, andequipment. This standard does not purport to address thesafety concerns associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety andhealth practices and det
6、ermine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 412 Test Methods for Vulcanized Rubber and Thermo-plastic ElastomersTensionD 471 Test Method for Rubber PropertyEffect of LiquidsD 518 Test Method for Rubber DeteriorationSurfaceCrackingD 573
7、Test Method for RubberDeterioration in an AirOvenD 624 Test Method for Tear Strength of ConventionalVulcanized Rubber and Thermoplastic ElastomersD 1079 Terminology Relating to Roofing and Waterproof-ingD 1149 Test Method for Rubber DeteriorationSurfaceOzone Cracking in a ChamberD 1204 Test Method f
8、or Linear Dimensional Changes ofNonrigid Thermoplastic Sheeting or Film at ElevatedTemperatureD 1418 Practice for Rubber and Rubber LaticesNomenclatureD 2137 Test Methods for Rubber PropertyBrittlenessPoint of Flexible Polymers and Coated FabricsD 3182 Practice for RubberMaterials, Equipment, andPro
9、cedures for Mixing Standard Compounds and Prepar-ing Standard Vulcanized SheetsG 151 Practice for Exposing Nonmetallic Materials in Ac-celerated Test Devices that Use Laboratory Light SourcesG 154 Practice for Operating Fluorescent Light Apparatusfor UV Exposure of Nonmetallic MaterialsG 155 Practic
10、e for Operating Xenon Arc Light Apparatusfor Exposure of Non-Metallic Materials3. Classification3.1 The following types are used to identify the principalpolymer components of the flashing material (see Note 1):3.1.1 Type IEthylene-Propylene-Diene Terpolymer(EPDM).3.1.2 Type IIChloroprene Polymer (C
11、R).NOTE 1For definitions of polymer types, see Practice D 1418. Fordefinitions of terms related to roofing, see Terminology D 1079.3.2 The following classes describe the ability to vulcanizeon the roof:1This specification is under the jurisdiction of ASTM Committee D08 onRoofing and Waterproofing an
12、d is the direct responsibility of Subcommittee D08.18on Nonbituminous Organic Roof Coverings.Current edition approved Dec. 1, 2006. Published January 2007. Originallyapproved in 1990. Last previous edition approved in 2004 as D 4811 04.2For referenced ASTM standards, visit the ASTM website, www.astm
13、.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.1 Clas
14、s VVulcanizing.3.2.2 Class NVNonvulcanizing.NOTE 2Class V compounds continue to vulcanize (that is, cure) afteremplacement on the roof. Class NV indicates non-vulcanizable com-pounds.4. Materials and Manufacture4.1 The flashing material shall be formulated from theappropriate polymer type and other
15、compounding ingredients.The principal polymer in the flashing material shall be one ofthose listed in 3.1 and greater than 95% of the total polymer.4.2 The flashing material shall be capable of being bondedto itself, to the roofing membrane, and to substrate for makingwatertight field splices and re
16、pairs. The manufacturer orfabricator shall recommend suitable bonding methods andmaterials.5. Physical Property Requirements5.1 Class V flashing material shall conform to the physicalproperty requirements prescribed in Table 1 and Table 2. ClassNV flashing material shall conform to the physical prop
17、ertyrequirements prescribed in Table 1.5.2 Other requirements shall be agreed upon between thepurchaser and the supplier as part of the purchase contract.6. Dimensions and Permissible Variations6.1 The width and length shall be agreed upon between thepurchaser and the supplier as part of the purchas
18、e contract.6.1.1 The width and length tolerance shall be+3%and0%.6.2 Sheet thicknesses greater than minimum shall be agreedupon between the purchaser and the supplier as part of thepurchase contract.6.2.1 The thickness tolerance shall be +15 % and 10 % ofthe specified thickness, but in no case shall
19、 the thickness beless than the minimum listed in Table 1.7. Workmanship, Finish, and Appearance7.1 The flashing material shall be visually free of pinholes,particles of foreign matter, undispersed raw materials, or othermanufacturing defects that might affect serviceability.7.2 If the number of irre
20、gularities appear excessive on asheet (or portion thereof), then its rejection should be negoti-ated between involved parties.7.3 Edges of the sheet shall be capable of being seamed toone another and to other roofing components without fishmouthing.8. Test Methods8.1 ThicknessTest Methods D 412.8.2
21、Green Strength:8.2.1 Test a fresh sample manufactured within one week.8.2.2 Condition Type I material at 23 6 2C (73 6 4F) fora minimum of 1 h and a maximum of 8 h before proceedingwith the testing.8.2.3 Decrystallize Type II material by placing in a circu-lating air oven at 70 6 2C (158 6 4F) for 1
22、5 min. Afterremoval from the oven, condition at 23 6 2C (73 6 4F) fora minimum of 1 h and a maximum of 8 h before proceedingwith the testing.8.2.4 After conditioning, die out a 13-mm (0.5-in.) dumb-bell (DieA) and determine the modulus at 100 % extension andthe ultimate elongation at 23 6 2C (73 6 4
23、F) in accordancewith Test Methods D 412.8.2.5 After conditioning, die out a 13-mm (0.5-in.) dumb-bell (Die A), condition in a circulating air oven at 50 6 2C(122 6 4F) for 15 min minimum and 30 min maximum anddetermine the modulus at 100 % extension and the ultimateelongation at 50 6 2C (122 6 4F) i
24、n accordance with TestMethods D 412.8.3 Shelf StabilityDetermine green strength in accordancewith 8.2 after aging in a circulating air oven for 46 h at 70 62C (158 6 4F).8.4 Vulcanizability:8.4.1 ForType I andType II, oven age for 166 h at 70 6 2C(158 6 4F).8.4.2 After removal from the oven, conditi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便