ASTM D4516-2000(2006)e1 Standard Practice for Standardizing Reverse Osmosis Performance Data《反渗透性能数据的标准化的标准操作规程》.pdf
《ASTM D4516-2000(2006)e1 Standard Practice for Standardizing Reverse Osmosis Performance Data《反渗透性能数据的标准化的标准操作规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4516-2000(2006)e1 Standard Practice for Standardizing Reverse Osmosis Performance Data《反渗透性能数据的标准化的标准操作规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4516 00 (Reapproved 2006)e1Standard Practice forStandardizing Reverse Osmosis Performance Data1This standard is issued under the fixed designation D 4516; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of l
2、ast revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTESections 2 and 3.1 were updated editorially in February 2007.1. Scope1.1 This practice covers the standardization of permeat
3、eflow and salt passage data for reverse osmosis (RO) systems.1.2 This practice is applicable to waters including brackishwaters and seawaters but is not necessarily applicable to wastewaters.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It
4、is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1129 Terminology Relating to WaterD 4194 Test Methods for Operating Characteris
5、tics of Re-verse Osmosis and Nanofiltration DevicesD 6161 Terminology Used for Microfiltration, Ultrafiltra-tion, Nanofiltration and Reverse Osmosis Membrane Pro-cesses3. Terminology3.1 For definitions of terms used in this practice, refer toTerminologies D 1129 and D 6161.3.2 For description of ter
6、ms relating to reverse osmosis,refer to Test Method D 4194 and Terminology D 6161.4. Summary of Practice4.1 This practice consists of calculating the permeate flowand salt passage of RO systems at a standard set of conditionsusing data obtained at actual operating conditions.5. Significance and Use5
7、.1 During the operation of an RO system, system condi-tions such as pressure, temperature, conversion, and feedconcentration can vary, causing permeate flow and salt passageto change. To effectively evaluate system performance, it isnecessary to compare permeate flow and salt passage data atthe same
8、 conditions. Since data may not always be obtained atthe same conditions, it is necessary to convert the RO dataobtained at actual conditions to a set of selected constantconditions, thereby standardizing the data. This practice givesthe procedure to standardize RO data.5.2 This practice can be used
9、 for both spiral wound andhollow fiber systems.5.3 This practice can be used for a single element or amulti-element system. However, if the RO system is brinestaged, that is, the brine from one group of RO devices is thefeed to a second group of RO devices, standardize the permeateflow and salt pass
10、age for each stage separately.5.4 This practice is applicable for reverse osmosis systemswith high rejections and with no significant leaks between thefeed-brine and permeate streams.6. Procedure6.1 Standardization of Permeate Flow:6.1.1 Calculate the permeate flow at standard conditionsusing Eq 1:Q
11、ps5FPfs2DPfbs22 Pps2pfbs1ppsGTCFs!FPfa2DPfba22 Ppa2pfba1ppaGTCFa!Qpa! (1)where:Qps= permeate flow at standard conditions,Pfs= feed pressure at standard conditions, kpa,DPfbs2= one half device pressure drop at standard condi-tions, kpa,Pps= permeate pressure at standard conditions, kpa,pfbs= feed-bri
12、ne osmotic pressure at standard condi-tions, kpa,pps= permeate osmotic pressure at standard condi-tions, kpa,1This practice is under the jurisdiction of ASTM Committee D19 on Water andis the direct responsibility of Subcommittee D19.08 on Membranes and IonExchange Materials.Current edition approved
13、Dec. 15, 2006. Published February 2007. Originallyapproved in 1985. Last previous edition approved in 2000 as D 4516 00 .2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refe
14、r to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.TCFs= temperature correction factor at standard condi-tions,Qpa= permeate flow at actual conditions,Pfa= feed pressure at act
15、ual conditions, kpa,DPfba2= one half device pressure drop at actual condi-tions, kpa,Ppa= permeate pressure at actual conditions, kpa,pfba= feed-brine osmotic pressure at actual conditions,kpa,ppa= permeate osmotic pressure at actual conditions,kpa, andTCFa= temperature correction factor at actual c
16、ondi-tions.6.2 Standardization of Salt Passage:6.2.1 Calculate the salt passage at standard conditionsusing Eq 2:%SPs5 EPFa/EPFs# 3 STCFa/STCFs# 3 Cfbs/Cfba! 3 Cfa/Cfs!3 %SPa(2)where:%SPs= percent salt passage normalized to standard (ref-erence) conditions,%SPa= percent salt passage at actual condit
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD451620002006E1STANDARDPRACTICEFORSTANDARDIZINGREVERSEOSMOSISPERFORMANCEDATA 反渗透 性能 数据 标准化 标准 操作规程

链接地址:http://www.mydoc123.com/p-517262.html