1、Designation: D3831 12Standard Test Method forManganese in Gasoline By Atomic AbsorptionSpectroscopy1This standard is issued under the fixed designation D3831; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisio
2、n. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determination of the totalmanganese content, present as methylcyclopentadienyl manga-nese tricarbonyl
3、 (MMT),2of gasoline within the concentrationrange from 0.25 to 40 mg/L of manganese.1.2 This test method is applicable to reformulated gasolinecontaining up to 12 % volume methyl tertiary butylether or upto 10 % volume ethanol. This test method may not be appli-cable to highly cracked materials cont
4、aining greater than 18volume % olefins as determined by Test Method D1319(nondepentanized).1.3 This test method has been developed and tested specifi-cally for the determination of MMT in gasoline over therecommended concentration range. Application of the methodto other concentration ranges, to the
5、 determination of MMT inother materials, or to the determination of other manganesecompounds in gasoline have not been tested1.4 The values stated in SI units are to be regarded as thestandard. The preferred concentration units are mg/L manga-nese.1.5 This standard does not purport to address all of
6、 thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specificwarning statements, see Sections 5 and 6.2. Referenced
7、 Documents2.1 ASTM Standards:3D1319 Test Method for Hydrocarbon Types in Liquid Petro-leum Products by Fluorescent Indicator AdsorptionD4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsD4177 Practice for Automatic Sampling of Petroleum andPetroleum ProductsD6299 Practice for Apply
8、ing Statistical Quality Assuranceand Control Charting Techniques to Evaluate AnalyticalMeasurement System PerformanceD6300 Practice for Determination of Precision and BiasData for Use in Test Methods for Petroleum Products andLubricantsD6792 Practice for Quality System in Petroleum Productsand Lubri
9、cants Testing LaboratoriesD7740 Practice for Optimization, Calibration, and Valida-tion of Atomic Absorption Spectrometry for Metal Analy-sis of Petroleum Products and Lubricants3. Summary of Test Method3.1 The gasoline sample is treated with bromine solutionand diluted with methyl isobutyl ketone.
10、The manganesecontent of the sample is determined by atomic absorptionspectrometry using an air-acetylene flame at 279.5 nm andstandards prepared from an organo-manganese standard mate-rial.3.2 Protocols for using atomic absorption spectrometry aregiven in Practice D7740.4. Significance and Use4.1 Ce
11、rtain organo-manganese compounds act as antiknockagents when added to gasoline. This test method provides ameans for determining the concentration of such a material ina gasoline sample.5. Apparatus5.1 Atomic Absorption Spectrometer , capable of scaleexpansion and equipped with a manganese hollow-ca
12、thodelamp for monitoring manganese absorption at 279.5 nm, apremix slot-type burner with rotatable burner head, and anadjustable nebulizer. (WarningHazardous. Potentially toxicand explosive. Refer to the manufacturers instrument manualfor associated safety hazards.)5.2 Vials, up to 40-mL size with p
13、olyethylene or TFE-fluorocarbon-lined caps or glass stoppers.1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.03 on Elemental Analysis.Current edition approved June 1, 2012. Published August 2012
14、. Originallyapproved in 1979. Last previous edition approved in 2006 as D3831 01(2006).DOI: 10.1520/D3831-12.2MMT is a registered trademark of Ethyl Corp.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMS
15、tandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.3 Pipet, Delivery, 1-mL si
16、ze.5.4 Micropipet, 100-L size, Eppendorf type or equivalent.5.5 Automatic Pipet, or equivalent delivery pipet, capable ofdelivering 9.0-mL quantities.6. Reagents6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall
17、conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.4Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of
18、 the determination.6.2 Bromine Solution Add reagent grade bromine to anequal volume of cyclohexane. (WarningBromine can causesevere and painful burns when it contacts the skin. In additionto other precautions, wear protective gloves in preparing thesolution and prepare, store, and use it in a well-v
19、entilatedhood.)6.3 Manganese Standard Solution 400 mg Mn/LDissolvethe appropriate amount of organometallic manganese standardin methyl isobutyl ketone to give a standard solution of 400 mgMn/L.6.4 Manganese, Standard Solution 4.0, 10.0, 20.0, and 40.0mg Mn/LDilute the 400 mg/L standard manganese sol
20、utionwith methyl isobutyl ketone using volumetric glassware to givethe desired lower concentration manganese standard solutions.6.5 Organometallic Manganese Standard Pre-preparedcommercially available organometallic stock solutions havebeen found to be satisfactory.6.6 Methyl Isobutyl Ketone, reagen
21、t grade. (WarningFlammable. Vapor harmful.) (Warning Solutions of MMTin gasoline are chemically unstable when exposed to light. Lowand erratic results may be obtained if the gasoline sample isexposed to light prior to stabilization during analysis.)6.7 Quality Control (QC) Sample(s) ,preferably are
22、a portion of one or more gasoline materials thatare stable and representative of the samples of interest.7. Sampling7.1 Take samples of gasoline in compliance with the in-structions in Practice D4057 or D4177 where appropriate.Analyze as soon as possible after sampling.8. Calibration8.1 Preparation
23、of Working Standards Prepare four work-ing standards using the 4.0, 10.0, 20.0, and 40.0 mg Mn/Lstandard manganese solutions described in 6.3.8.1.1 Using a micropipet, add 100 L of bromine solution toeach of four separate vials.8.1.2 Pipet 1 mL of each of the four low-manganesestandards into each of
24、 the vials. Mix with the bromine solutionby swirling the vials.8.1.3 Deliver 9.0 mL of methyl isobutyl ketone to each ofthe vials. Mix well. This tenfold dilution of the low-manganesestandards is the same as the final dilution of the sample.8.2 Preparation of InstrumentSet the atomic absorptionspect
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD38312012STANDARDTESTMETHODFORMANGANESEINGASOLINEBYATOMICABSORPTIONSPECTROSCOPY 原子 吸收 分光光度法 测定 汽油

链接地址:http://www.mydoc123.com/p-515586.html