ASTM D2729-2017 Standard Specification for Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings《聚氯乙烯(PVC)污水管和配件的标准规格》.pdf
《ASTM D2729-2017 Standard Specification for Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings《聚氯乙烯(PVC)污水管和配件的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2729-2017 Standard Specification for Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings《聚氯乙烯(PVC)污水管和配件的标准规格》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2729 11D2729 17Standard Specification forPoly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings1This standard is issued under the fixed designation D2729; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last r
2、evision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, chemical resistance, andjoi
3、nt tightness of poly(vinyl chloride) (PVC) sewer and drain pipe and fittings. Perforated pipe is also covered; the joint tightnesstest is not applicable for perforated pipe. A form of marking to indicate compliance with this specification is also included.1.2 The text of this specification reference
4、s notes, footnotes, and appendixes which provide explanatory material. These notesand footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in paren
5、theses are for informationonly.1.4 The following precautionary caveat pertains only to the test methods portion, Section 67, of this specification: This standarddoes not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of thisstanda
6、rd to establish appropriate safety safety, health, and healthenvironmental practices and determine the applicability ofregulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decis
7、ion on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D618 Practice for Conditioning Plastics for TestingD1600 Terminology for Abbreviat
8、ed Terms Relating to PlasticsD1784 Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC)CompoundsD2122 Test Method for Determining Dimensions of Thermoplastic Pipe and FittingsD2152 Test Method for Adequacy of Fusion of Extruded Poly(Vinyl Chloride)
9、 (PVC) Pipe and Molded Fittings by AcetoneImmersionD2321 Practice for Underground Installation of Thermoplastic Pipe for Sewers and Other Gravity-Flow ApplicationsD2412 Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate LoadingD2444 Test Method for De
10、termination of the Impact Resistance of Thermoplastic Pipe and Fittings by Means of a Tup (FallingWeight)D2564 Specification for Solvent Cements for Poly(Vinyl Chloride) (PVC) Plastic Piping SystemsF412 Terminology Relating to Plastic Piping Systems2.2 Federal Standard:Fed. Std. No. 123 Marking for
11、Shipment (Civil Agencies)32.3 Military Standard:MIL-STD-129 Marking for Shipment and Storage31 This specification is under the jurisdiction of ASTM Committee F17 on Plastic Piping Systems and is the direct responsibility of Subcommittee F17.62 on Sewer.Current edition approved Feb. 1, 2011Sept. 1, 2
12、017. Published February 2011November 2017. Originally approved in 1968. Last previous edition approved in 20032011as D2729 03.D2729 11. DOI: 10.1520/D2729-11.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of AS
13、TM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 Available from Standardization Documents Order Desk, Bldg. 4 Section D, DLA Document Services, Building 4/D, 700 Robbins Ave., Philadelphia, PA 19111-5094,Attn: NPODS.http:/quicksearch.dla.mil.This doc
14、ument is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as
15、 appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. Unite
16、d States13. Terminology3.1 DefinitionsDefinitions used are in accordance with Terminology F412, and abbreviations are in accordance withTerminology D1600, unless otherwise specified. The abbreviation for poly(vinyl chloride) is PVC.3.1.1 perforated pipePipe having perforations is called perforated p
17、ipe; without perforations it is called standard pipe. pipehaving holes cut through the wall along its length.4. Significance and Use4.1 The pipe and fittings in this specification are designed and have the physical, chemical, and other properties for sewer anddrainage applications outside the buildi
18、ng. The pipe is not intended for use as public or municipal collector sewers. The followinglists the typical applications for the sewer and drain pipe:4.1.1 Building sewers and underground drainsstandard,4.1.2 Storm drainagestandard and perforated,4.1.3 House connections to septic tanksstandard,4.1.
19、4 Leaching system piping for septic tank effluentsstandard and perforated,4.1.5 Footing drains (foundation drains)standard and perforated,4.1.6 Industrial waste disposalstandard and perforated, and4.1.7 Land drainagestandard and perforated.5. Materials5.1 GeneralThe pipe shall be made from virgin ce
20、ll PVC compound with a cell classification of 12164 with a minimum tensilestrength of 4000 psi (28 MPa), or 12454 poly(vinyl chloride) compounds, as defined and described in Specification D1784. Thefittings shall be made from virgin poly(vinyl chloride) compounds of cell classification PVC 12454, or
21、 PVC 13343. CompoundsPVC compounds that have different cell classification because one or more properties are superior to those of the specifiedcompounds are also acceptable.5.2 Rework MaterialThe manufacturer shall use only his own clean pipe or fitting rework material; the pipe and fittingsproduce
22、d shall meet all the requirements of this specification.6. Requirements6.1 Qualification and Referee Testing:6.1.1 Joint TestingJoints made with pipe and fittings or belled end pipe shall show no signs of leakage when tested inaccordance with 6.57.5. This test is not required for perforated pipe.6.2
23、 Quality Control Testing:6.2.1 WorkmanshipThe pipe and fittings shall be homogeneous throughout and free from visible cracks, holes, foreigninclusions, or other injurious defects. The pipe shall be as uniform as commercially practical in color, opacity, density, and otherphysical properties.6.2.2 Fl
24、atteningThere shall be no evidence of splitting, cracking, or breaking when the pipe is tested in accordance with6.47.4.6.2.3 Extrusion QualityThe pipe or fittings shall not flake or disintegrate when tested in accordance with Test Method D2152.In the case of fittings, slight flaking in the gate are
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD27292017STANDARDSPECIFICATIONFORPOLYVINYLCHLORIDEPVCSEWERPIPEANDFITTINGS 聚氯乙烯 PVC 污水 配件 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-513431.html