1、Designation: D 2729 03An American National StandardStandard Specification forPoly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings1This standard is issued under the fixed designation D 2729; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revis
2、ion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification
3、covers requirements and test methodsfor materials, dimensions, workmanship, chemical resistance,and joint tightness of poly(vinyl chloride) (PVC) sewer anddrain pipe and fittings. Four-inch perforated pipe is alsocovered; the joint tightness test is not applicable for thisproduct. A form of marking
4、to indicate compliance with thisspecification is also included.1.2 The text of this specification references notes, footnotes,and appendixes which provide explanatory material. Thesenotes and footnotes (excluding those in tables and figures) shallnot be considered as requirements of the specificatio
5、n.1.3 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.1.4 The following precautionary caveat pertains only to thetest methods portion, Section 6, of this specification: Thisstandard does not purport to address all of th
6、e safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.2. Referenced Documents2.1 ASTM Standards:D 618 Practice for Conditionin
7、g Plastics and ElectricalInsulating Materials for Testing2D 1600 Terminology for Abbreviated Terms Relating toPlastics2,3D 1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)Compounds and Chlorinated Poly(Vinyl Chloride)(CPVC) Compounds3D 2122 Test Method for Determining Dimensions of Ther-mopla
8、stic Pipe and Fittings3D 2152 Test Method for Adequacy of Fusion of ExtrudedPoly(Vinyl Chloride) (PVC) Pipe and Molded Fittings byAcetone Immersion3D 2321 Practice for Underground Installation of Thermo-plastic Pipe for Sewers and Other Gravity-Flow Applica-tions3D 2412 Test Method for Determination
9、 of External LoadingCharacteristics of Plastic Pipe by Parallel-Plate Loading3D 2444 Test Method for Impact Resistance of Thermoplas-tic Pipe and Fittings by Means of a Tup (Falling Weight)3D 2564 Specification for Solvent Cements for Poly(VinylChloride) (PVC) Plastic Piping Systems3F 412 Terminolog
10、y Relating to Plastic Piping Systems32.2 Federal Standard:Fed. Std. No. 123 Marking for Shipment (Civil Agencies)42.3 Military Standard:MIL-STD-129 Marking for Shipment and Storage43. Terminology3.1 DefinitionsDefinitions used are in accordance withTerminology F 412, and abbreviations are in accorda
11、nce withTerminology D 1600, unless otherwise specified. The abbre-viation for poly(vinyl chloride) is PVC.3.1.1 Pipe having perforations is called perforated pipe;without perforations it is called standard pipe.4. Materials4.1 GeneralThe pipe shall be made from virgin cell12164 with a minimum tensil
12、e strength of 4000 psi (28 MPa),12454 or 12454 poly(vinyl chloride) compounds, as definedand described in Specification D 1784. The fittings shall bemade from virgin poly(vinyl chloride) compounds of cellclassification PVC 12454, PVC 12454, or PVC 13343. Com-pounds that have different cell classific
13、ation because one ormore properties are superior to those of the specified com-pounds are also acceptable.4.2 Rework MaterialThe manufacturer shall use only hisown clean pipe or fitting rework material; the pipe and fittingsproduced shall meet all the requirements of this specification.5. Requiremen
14、ts5.1 Qualification and Referee Testing:1This specification is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.62 on Sewer.Current edition approved Aug. 10, 2003. Published September 2003. Originallyapproved in 1968. Last pre
15、vious edition approved in 1996 as D 2729 96a.2Annual Book of ASTM Standards, Vol 08.01.3Annual Book of ASTM Standards, Vol 08.04.4Available from Standardization Documents Order Desk, Bldg. 4 Section D, 700Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.1Copyright ASTM International, 100 Barr
16、Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.1.1 Joint TestingJoints made with pipe and fittings orbelled end pipe shall show no signs of leakage when tested inaccordance with 6.5. This test is not required for perforatedpipe.5.2 Quality Control Testing:5.2.1 Workmans
17、hipThe pipe and fittings shall be homo-geneous throughout and free from visible cracks, holes, foreigninclusions, or other injurious defects. The pipe shall be asuniform as commercially practical in color, opacity, density,and other physical properties.5.2.2 FlatteningThere shall be no evidence of s
18、plitting,cracking, or breaking when the pipe is tested in accordancewith 6.4.5.2.3 Extrusion QualityThe pipe or fittings shall not flakeor disintegrate when tested in accordance with Test MethodD 2152. In the case of fittings, slight flaking in the gate area isacceptable.NOTE 1This test is intended
19、only for use as a quality control test, notfor use as a simulated service test.5.2.4 Impact ResistanceThe impact resistance of pipeshall be determined in accordance with Test Method D 2444,using a 20-lb (10-kg) TupAand Holder B (flat plate), and shallcomply with the requirements given in Table 1 (No
20、te 1). Forperforated pipe, samples are to be cut and tested at randomwithout regard to hole location, except that the point of impactshall not coincide with a perforation.5.2.5 Dimensions:5.2.5.1 Pipe and fittings dimensions (for both standard andperforated pipe) shall comply with Table 2, Table 3,
21、or Table 4,as applicable, when measured in accordance with Test MethodD 2122.5.2.5.2 Pipe shall be supplied in 10 ft 614-in. layinglengths unless otherwise specified.5.2.5.3 For belled pipe and fittings fabricated from pipesections, the thickness of the belled section shall be consideredsatisfactory
22、 if the bell was formed from pipe meeting therequirements of Table 3.5.2.5.4 For molded fittings, the wall thickness of the water-way and socket or bell shall be no less than the respectiveminimum thickness listed for the equivalent pipe wall in Table3. For reducing fittings or those with smaller in
23、lets, theminimum wall thickness of each inlet shall be no less than theminimum wall thickness for that size pipe.5.2.6 Pipe StiffnessThe pipe stiffness at 5 % deflection(F/Dy) shall not be less than the values given in Table 5 whentested in accordance with Test Method D 2412. This require-ment does
24、not apply to fittings.NOTE 2The 5 % deflection criterion, which was arbitrarily selectedfor testing convenience, should not be considered as a limitation withrespect to in-use deflection. The engineer is responsible for establishingthe acceptable limit.Note 3The strength and load-carrying capabiliti
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD27292003STANDARDSPECIFICATIONFORPOLYVINYLCHLORIDEPVCSEWERPIPEANDFITTINGS 聚氯乙烯 PVC 污水 配件 标准规范 PDF

链接地址:http://www.mydoc123.com/p-513429.html