ASTM D2523-2013 Standard Practice for Testing Load-Strain Properties of Roofing Membranes《屋顶隔膜荷载应变特性测试的标准操作规程》.pdf
《ASTM D2523-2013 Standard Practice for Testing Load-Strain Properties of Roofing Membranes《屋顶隔膜荷载应变特性测试的标准操作规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2523-2013 Standard Practice for Testing Load-Strain Properties of Roofing Membranes《屋顶隔膜荷载应变特性测试的标准操作规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2523 13Standard Practice forTesting Load-Strain Properties of Roofing Membranes1This standard is issued under the fixed designation D2523; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A n
2、umber in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice is a guide for determining the load-strainproperties of roofing membranes and their components atvarious temperatures. Tes
3、t specimens may be prepared in thelaboratory or cut from samples obtained in the field.1.2 The values stated in SI units are to be regarded as thestandard. The inch-pound units given in parentheses are forinformation only.1.3 This standard does not purport to address all of thesafety concerns, if an
4、y, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D95 Test Method for Water in Petroleum Products an
5、dBituminous Materials by DistillationD412 Test Methods for Vulcanized Rubber and Thermoplas-tic ElastomersTensionE178 Practice for Dealing With Outlying Observations3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 roofing membranethat part of the roofing systemwhose primary fun
6、ction is to exclude water; it does not includefield-applied aggregate.4. Significance and Use4.1 This practice is designed to aid those interested in theengineering properties of roofing membranes.4.2 The data obtained will not permit prediction of theservice life of a membrane under field condition
7、s. The data willprovide a basis for study of the mechanical properties of themembrane. Note that if strain rates, specimen dimensions,initial clear distance between clamps, or temperatures andmoisture contents are varied, the data may not be strictlycomparable.5. Sampling5.1 Take field membrane samp
8、le at least 100 by 250 mm (4by 10 in.) in accordance with good roofing practices. In caseswhere field-applied aggregate is in place, remove it with ascraper such as a heated putty knife.5.1.1 Sample those areas of the membrane that are expectedto represent the extremes in load/strain characteristics
9、.5.1.2 At least one sample is required for each test tempera-ture at which it is desired to determine load/strain properties.5.2 Prepare laboratory samples at least 200 by 300 mm (8by 12 in.) in strict accordance with the roofing specificationbeing tested. Observe all cautions specified, such as not
10、overheating the bitumen. Do not oven condition any of thecomponents or the final sample.5.2.1 Select those areas of the membrane that are expectedto represent the extremes in load-strain characteristics. Prepareat least one sample of each type for each proposed testtemperature. If there is any doubt
11、 about these areas, include allpossible variations. The samples must be uniform in crosssection.5.2.2 Select materials at random when possible. Compo-nents should be conditioned at 50 6 5 % relative humidity and25 6 2.5C (77 6 4.5F) for 24 h prior to constructingsamples.5.2.3 The quantity of materia
12、l in any layer should be within610 %, and the entire sample should be within 65 % of thequantities specified.6. Test Specimens6.1 Condition the samples at room temperature at 50 6 5%relative humidity for a minimum of 16 h for non-solvent-containing membranes, and until constant mass has beenreached
13、for solvent-containing membranes.6.2 Die-cut three tension test specimens from each sample.The shape of the specimens for membranes with less than 50 %ultimate elongation is shown in Fig. 1. Where the membranehas an ultimate elongation greater than 50 %, use Die C of TestMethods D412.1This practice
14、is under the jurisdiction ofASTM Committee D08 on Roofing andWaterproofing and is the direct responsibility of Subcommittee D08.20 on RoofingMembrane Systems.Current edition approved June 15, 2013. Published July 2013. Originallyapproved in 1966. Last previous edition approved in 2006 as D2523 00 (2
15、006).DOI: 10.1520/D2523-13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD25232013STANDARDPRACTICEFORTESTINGLOADSTRAINPROPERTIESOFROOFINGMEMBRANES 屋顶 隔膜 荷载 应变 特性 测试 标准 操作规程

链接地址:http://www.mydoc123.com/p-513037.html