《ASTM D2247-2002 Standard Practice for Testing Water Resistance of Coatings in 100% Relative Humidity《涂层在100%相对湿度下耐水性的试验的标准操作规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2247-2002 Standard Practice for Testing Water Resistance of Coatings in 100% Relative Humidity《涂层在100%相对湿度下耐水性的试验的标准操作规程》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 2247 02Standard Practice forTesting Water Resistance of Coatings in 100 % RelativeHumidity1This standard is issued under the fixed designation D 2247; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This practice covers the basic principles
3、 and operatingprocedures for testing water resistance of coatings by exposingcoated specimens in an atmosphere maintained at 100 %relative humidity so that condensation forms on the testspecimens.1.2 This practice is limited to the methods of obtaining,measuring, and controlling the conditions and p
4、rocedures oftests conducted in 100 % relative humidity. It does not specifyspecimen preparation, specific test conditions, or evaluation ofresults.NOTE 1Alternative practices for testing the water resistance ofcoatings include Practices D 870, D 1735, and D 4585.1.3 The values stated in SI units are
5、 to be regarded as thestandard. The values given in parentheses are for informationonly.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices
6、 and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:D 609 Practice for Preparation of Cold-Rolled Steel Panelsfor Testing Paint, Varnish, Conversion Coatings, andRelated Coating Products2D 610 Test Method for Evaluating Degree of Rusting
7、 onPainted Steel Surfaces3D 714 Test Method for Evaluating Degree of Blistering ofPaints2D 823 Practices for Producing Films of Uniform Thicknessof Paint, Varnish, and Related Products on Test Panels2D 870 Practice for Testing Water Resistance of CoatingsUsing Water Immersion2D 1193 Specification fo
8、r Reagent Water4D 1654 Test Method for Evaluation of Painted or CoatedSpecimens Subjected to Corrosive Environment2D 1730 Practices for Preparation of Aluminum andAluminum-Alloy Surfaces for Painting5D 1735 Practice for Testing Water Resistance of CoatingsUsing Water Fog Apparatus2D 2616 Test Method
9、 for Evaluation of Visual Color Differ-ence With a Gray Scale2D 3359 Test Methods for Measuring Adhesion by TapeTest2D 3363 Test Method for Film Hardness by Pencil Test2D 4541 Test Method for Pull-Off Strength of CoatingsUsing Portable Adhesion Testers3D 4585 Practice for Testing Water Resistance of
10、 CoatingsUsing Controlled Condensation23. Summary of Practice3.1 Coated specimens are placed in an enclosed chambercontaining a heated, saturated mixture of air and water vapor.The temperature of the chamber is usually maintained at 38C(100F). At 100 % relative humidity (RH), a very smalltemperature
11、 difference between the specimen and the surround-ing vapor causes the formation of condensation on the speci-mens. The exposure condition is varied by selecting theduration of the test. Water permeates the coating at rates thatare dependent upon the characteristics of the coating. Anyeffects such a
12、s color change, blistering, loss of adhesion,softening, or embrittlement are observed and reported.4. Significance and Use4.1 Water can cause the degradation of coatings, so knowl-edge of how a coating resists water is helpful in predicting itsservice life. Failure in tests at 100 % relative humidit
13、y may becaused by a number of factors including a deficiency in thecoating itself, contamination of the substrate, or inadequatesurface preparation. This practice is therefore useful for evalu-ating coatings alone or complete coating systems.1This practice is under the jurisdiction of ASTM Committee
14、 D01 on Paint andRelated Coatings, Materials, and Applications and is the direct responsibility ofSubcommittee D01.27 on Accelerated Testing.Current edition approved Aug. 10, 2002. Published October 2002. Originallypublished as D 2247 66 T. Last previous edition D 2247 99.2Annual Book of ASTM Standa
15、rds, Vol 06.01.3Annual Book of ASTM Standards, Vol 06.02.4Annual Book of ASTM Standards, Vol 11.01.5Annual Book of ASTM Standards, Vol 02.05.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.2 Tests at 100 % relative humidity are use
16、d for specifica-tion acceptance, quality control, and research and developmentof coatings and substrate treatments. These tests usually resultin a pass or fail determination, but the degree of failure mayalso be measured. A coating system is considered to pass ifthere is no evidence of water-related
17、 failure after a period oftime.4.3 Results obtained from the use of 100 % humidity tests inaccordance with this practice should not be represented asbeing equivalent to a period of exposure to water in the naturalenvironment, until the degree of quantitative correlation hasbeen established for the c
18、oating or coating system.4.4 The test chamber can be a small laboratory cabinet or aroom large enough to hold an automobile or a truck. Someautomobile manufacturers test completed vehicles in roomsmaintained at 100 % relative humidity. Corrosion tests can beconducted, as the condensate dripping off
19、the test articles is notrecirculated.5. Apparatus5.1 Test Chamber, constructed of corrosion-resistant mate-rials with supports for the test specimens.5.2 Heated Water Tank, within the test chamber, a watersupply, and a water level control.5.3 Thermostatic Control, for the water heater with thesensor
20、 located adjacent to the specimen holders.5.4 Thermometer, with sensor located adjacent to the speci-men holders.5.5 Diagrams and details of the apparatus are shown in theAnnex.6. Test Specimens6.1 This practice does not cover the preparation of testspecimens. The substrate composition and surface p
21、reparation,specimen preparation, and the number of specimens should beagreed upon prior to testing.NOTE 2Applicable methods for the preparation of test panels andsubstrates are given in Practices D 609 and D 1730. Practices D 823 coverapplication techniques for the production of uniform films.6.2 It
22、s recommended that a control specimen of a paintwith known durability be included with each test. Such controlspecimens can provide warning of changes in test severity in agiven apparatus, and can indicate variations in test severitybetween different apparatuses.6.3 Its recommended that at least two
23、 replicate specimensof each different coating be used, so as to compensate forvariations between specimens and variations in test conditionswith the apparatus.7. Procedure7.1 Fill the water tank with reagent water conforming toType IV of Specification D 1193. Tap water should not be used.7.2 Adjust
24、the temperature of the saturated air and watervapor mixture to 38 6 2C (100 6 4F).NOTE 3Due to heat loss to the specimens and the walls of thechamber, the temperature of the water in the tank will be above thetemperature of the air and water vapor mixture.7.3 Support the specimens approximately 15 f
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD22472002STANDARDPRACTICEFORTESTINGWATERRESISTANCEOFCOATINGSIN100RELATIVEHUMIDITY 涂层 100 相对湿度 耐水性

链接地址:http://www.mydoc123.com/p-511293.html