1、Designation: C90 13Standard Specification forLoadbearing Concrete Masonry Units1This standard is issued under the fixed designation C90; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the year of last revision. A number in parenth
2、eses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This specification covers hollow and solid (see 5.3 and5.4) concrete m
3、asonry units made from hydraulic cement,water, and mineral aggregates with or without the inclusion ofother materials. There are three classes of concrete masonryunits: (1) normal weight, (2) medium weight, and (3) light-weight. These units are suitable for both loadbearing andnonloadbearing applica
4、tions.1.2 Concrete masonry units covered by this specification aremade from lightweight or normal weight aggregates, or both.NOTE 1The requirements of this specification have been researched,evaluated, and established for over a century, resulting in the physicalproperties and attributes defined her
5、e. These requirements are uniquelyand solely applicable to concrete masonry units manufactured on equip-ment using low or zero slump concrete and the constituent materialsdefined herein. Many performance attributes of concrete masonry units areindirectly accounted for, or inherently reflected within
6、, the requirementsof this specification without direct measurement, assessment, or evalua-tion. Applying the requirements of this specification to products that maybe similar in appearance, use, or nature to those covered by thisspecification may not address all pertinent physical properties necessa
7、ry toensure performance or serviceability of the resulting construction inreal-world applications under typical exposure environments. Productsmanufactured using alternative materials, manufacturing methods, orcuring processes not covered by this specification should not be evaluatedsolely using the
8、 requirements in this specification; however, developers ofnew products can consider the property requirements of this specificationas a beginning benchmark for unit performance. It is reasonable to testnew products for system performance as well as unit performance.1.3 The text of this specificatio
9、n references notes andfootnotes which provide explanatory material. These notes andfootnotes (excluding those in tables and figures) shall not beconsidered as requirements of the standard.1.4 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mat
10、hematicalconversions to SI units that are provided for information onlyand are not considered standard.NOTE 2When particular features are desired such as surface texturesfor appearance or bond, finish, color, or particular properties such asdensity classification, higher compressive strength, fire r
11、esistance, thermalperformance or acoustical performance, these features should be specifiedseparately by the purchaser. Suppliers should be consulted as to theavailability of units having the desired features.2. Referenced Documents2.1 ASTM Standards:2C33 Specification for Concrete AggregatesC140 Te
12、st Methods for Sampling and Testing ConcreteMasonry Units and Related UnitsC150 Specification for Portland CementC331 Specification for Lightweight Aggregates for ConcreteMasonry UnitsC426 Test Method for Linear Drying Shrinkage of ConcreteMasonry UnitsC595 Specification for Blended Hydraulic Cement
13、sC618 Specification for Coal Fly Ash and Raw or CalcinedNatural Pozzolan for Use in ConcreteC979 Specification for Pigments for Integrally Colored Con-creteC989 Specification for Slag Cement for Use in Concrete andMortarsC1157 Performance Specification for Hydraulic CementC1232 Terminology of Masonr
14、yC1240 Specification for Silica Fume Used in CementitiousMixturesC1314 Test Method for Compressive Strength of MasonryPrismsE519 Test Method for Diagonal Tension (Shear) in MasonryAssemblagesE72 Test Methods of Conducting Strength Tests of Panelsfor Building Construction3. Terminology3.1 Terminology
15、 defined in Terminology C1232 shall applyfor this specification.1This specification is under the jurisdiction of ASTM Committee C15 onManufactured Masonry Units and is the direct responsibility of SubcommitteeC15.03 on Concrete Masonry Units and Related Units.Current edition approved June 1, 2013. P
16、ublished June 2013. Originallyapproved in 1931. Last previous edition approved in 2012 as C90 12. DOI:10.1520/C0090-13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer
17、to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14. Materials4.1 Cementitious MaterialsMaterials shall conform t
18、o thefollowing applicable specifications:4.1.1 Portland CementSpecification C150.4.1.2 Modified Portland CementPortland cement con-forming to Specification C150, modified as follows:(1) LimestoneIf calcium carbonate is added to thecement, the CaCO3content shall not be less than 85 %.(2) Limitation o
19、n Insoluble Residue1.5 %.(3) Limitation on Air Content of MortarVolume percent,22 % max.(4) Limitation on Loss on Ignition7 %.4.1.3 Blended Hydraulic CementsSpecification C595.4.1.4 Hydraulic CementSpecification C1157.4.1.5 PozzolansSpecification C618.4.1.6 Blast Furnace Slag CementSpecification C98
20、9.4.1.7 Silica FumeSpecification C1240.4.2 AggregatesAggregates shall conform to the followingspecifications, except that grading requirements shall notnecessarily apply:4.2.1 Normal Weight AggregatesSpecification C33.4.2.2 Lightweight AggregatesSpecification C331.4.3 Pigments for Integrally Colored
21、 ConcreteSpecification C979.4.4 Other ConstituentsAir-entraining agents, integral wa-ter repellents, and other constituents shall be previously estab-lished as suitable for use in concrete masonry units and shallconform to applicable ASTM standards or shall be shown bytest or experience not to be de
22、trimental to the durability of theconcrete masonry units or any material customarily used inmasonry construction.5. Physical Requirements5.1 At the time of delivery to the purchaser, units shallconform to the physical requirements prescribed in Table 1 andTable 2. All units shall be sound and free o
23、f cracks or otherdefects that interfere with the proper placement of the unit orsignificantly impair the strength or permanence of the construc-tion. Minor cracks, incidental to the usual method of manufac-ture or minor chipping resulting from customary methods ofhandling in shipment and delivery, a
24、re not grounds for rejec-tion.NOTE 3Higher compressive strengths than those listed in Table 2 maybe specified where required by design. Consult with suppliers to determineavailability of units of higher compressive strength.NOTE 4Oven-dry densities of concrete masonry units generally fallwithin the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC902013STANDARDSPECIFICATIONFORLOADBEARINGCONCRETEMASONRYUNITS 耐火砖 异型 砖模数 系列 尺寸 规格 标准 操作规程 PDF

链接地址:http://www.mydoc123.com/p-508715.html