ASTM C76M-2014 Standard Specification for Reinforced Concrete Culvert Storm Drain and Sewer Pipe &40 Metric&41 《钢筋混凝土制涵洞、雨水道和污水管的标准规格(公制)》.pdf
《ASTM C76M-2014 Standard Specification for Reinforced Concrete Culvert Storm Drain and Sewer Pipe &40 Metric&41 《钢筋混凝土制涵洞、雨水道和污水管的标准规格(公制)》.pdf》由会员分享,可在线阅读,更多相关《ASTM C76M-2014 Standard Specification for Reinforced Concrete Culvert Storm Drain and Sewer Pipe &40 Metric&41 《钢筋混凝土制涵洞、雨水道和污水管的标准规格(公制)》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C76M 14Standard Specification forReinforced Concrete Culvert, Storm Drain, and Sewer Pipe(Metric)1This standard is issued under the fixed designation C76M; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of la
2、st revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This specification covers reinforc
3、ed concrete pipe in-tended to be used for the conveyance of sewage, industrialwastes, and storm water, and for the construction of culverts.1.2 This specification is the SI companion to SpecificationC76.NOTE 1This specification is a manufacturing and purchase specifica-tion only, and does not includ
4、e requirements for bedding, backfill, or therelationship between field load condition and the strength classification ofpipe. However, experience has shown that the successful performance ofthis product depends upon the proper selection of the class of pipe, typeof bedding and backfill, controlled m
5、anufacture in the plant, and care andinstallation conforms to the construction specifications. The owner of thereinforced concrete pipe specified herein is cautioned that he mustcorrelate the field requirements with the class of pipe specified andprovide inspection at the construction site.NOTE 2Att
6、ention is called to the specification for reinforced concreteD-load culvert, storm drain, and sewer pipe (ASTM Designation C655M).2. Referenced Documents2.1 ASTM Standards:2A36/A36M Specification for Carbon Structural SteelA615/A615M Specification for Deformed and Plain Carbon-Steel Bars for Concret
7、e ReinforcementA706/A706M Specification for Low-Alloy Steel Deformedand Plain Bars for Concrete ReinforcementA1064/A1064M Specification for Carbon-Steel Wire andWelded Wire Reinforcement, Plain and Deformed, forConcreteC33 Specification for Concrete AggregatesC150 Specification for Portland CementC2
8、60 Specification for Air-Entraining Admixtures for Con-creteC309 Specification for Liquid Membrane-Forming Com-pounds for Curing ConcreteC494/C494M Specification for Chemical Admixtures forConcreteC497M Test Methods for Concrete Pipe, Manhole Sections,or Tile (Metric)C595 Specification for Blended H
9、ydraulic CementsC618 Specification for Coal Fly Ash and Raw or CalcinedNatural Pozzolan for Use in ConcreteC655M Specification for Reinforced Concrete D-LoadCulvert, Storm Drain, and Sewer Pipe (Metric)C822 Terminology Relating to Concrete Pipe and RelatedProductsC989 Specification for Slag Cement f
10、or Use in Concrete andMortarsC1017/C1017M Specification for Chemical Admixtures forUse in Producing Flowing ConcreteC1116 Specification for Fiber-Reinforced Concrete andShotcreteC1602/C1602M Specification for Mixing Water Used in theProduction of Hydraulic Cement Concrete3. Terminology3.1 Definition
11、sFor definitions of terms relating to con-crete pipe, see Terminology C822.4. Classification4.1 Pipe manufactured in accordance with this specificationshall be of five classes identified as Class I, Class II, Class III,Class IV, and Class V. The corresponding strength require-ments are prescribed in
12、 Tables 1-5.5. Basis of Acceptance5.1 Unless otherwise designated by the owner at the time of,or before placing an order, there are two separate and alterna-tive bases of acceptance. Independent of the method ofacceptance, the pipe shall be designed to meet both the 0.01-in.crack and ultimate streng
13、th requirements specified in Tables1-5.5.1.1 Acceptance on the Basis of Plant Load-Bearing Tests,Material Tests, and Inspection of Manufactured Pipe for Visual1This specification is under the jurisdiction of ASTM Committee C13 onConcrete Pipe and is the direct responsibility of Subcommittee C13.02 o
14、nReinforced Sewer and Culvert Pipe.Current edition approved Feb. 1, 2014. Published March 2014. Originallyapproved in 1980. Last previous edition approved in 2013 as C76M 13a. DOI:10.1520/C0076M-14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service
15、at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1NOTE 1The total reinforcement area of the inner c
16、ircular cage and the elliptical cage shall not be less than that specified for the inner cage in Tables1-5.NOTE 2The total reinforcement area of the outer circular cage and the elliptical cage shall not be less than that specified for the outer cage in Tables1-5.FIG. 1 Triple Cage ReinforcementTABLE
17、 1 Design Requirements for Class I Reinforced Concrete PipeANOTE 1See Section 5 for basis of acceptance specified by owner.The strength test requirements in newtons per linear metre of pipe under the three-edge-bearing method shall be either the D-load (test load expressedin newtons per linear metre
18、 per millimetre of diameter) to produce the 0.3-mm crack, or the D-loads to produce the 0.3-mm crack and the ultimate loadas specified below, multiplied by the internal diameter of the pipe in millimetres.D-load to produce a 0.3 mm crack 40.0D-load to produce the ultimate load 60.0InternalDesignated
19、Diameter,mmReinforcement, cm2/linear m of pipe wallWall A Wall BConcrete Strength, 27.6 MPa Concrete Strength, 27.6 MPaWallThickness,mmCircularReinforcementBEllipticalReinforcementCWallThickness,mmCircularReinforcementBEllipticalReinforcementCInnerCageOuterCageInnerCageOuterCage1500 125 5.3 3.2 5.9
20、150 4.4 2.6 4.91650 138 6.4 3.8 7.0 163 5.3 3.2 5.91800 150 7.4 4.4 8.3 175 6.1 3.7 6.81950 163 8.5 5.1 9.3 188 6.8 4.1 7.62100 175 9.5 5.7 10.6 200 7.8 4.7 8.72250 188 10.4 6.2 11.4 213 8.7 5.2 9.72400 200 11.4 6.8 12.7 225 9.7 5.8 10.8Concrete Strength, 34.5 MPa2550 213 13.3 8.0Inner CircularPlus
21、Elliptical5.38.0238 11.4 6.8Inner CircularPlus Elliptical4.66.82700 225 14.4 8.6Inner CircularPlus Elliptical5.88.6250 12.9 7.7Inner CircularPlus Elliptical5.27.72850A. . . .A. . . .3000A. . . .A. . . .3150A. . . .A. . . .3300A. . . .A. . . .3450A. . . .A. . . .3600A. . . .A. . . .AFor modified or s
22、pecial designs, see 7.2 or with the permission of the owner utilize the provisions of Specification C655M. Steel areas may be interpolated betweenthose shown for variations in diameter, loading, or wall thickness. Pipe over 2400 mm in diameter shall have two circular cages or an inner circular plus
23、one elliptical cage.BAs an alternative to designs requiring both inner and outer circular cages the reinforcement may be positioned and proportioned in either of the following manners:An inner circular cage plus an elliptical cage such that the area of the elliptical cage shall not be less than that
24、 specified for the outer cage in the table and the total areaof the inner circular cage plus the elliptical cage shall not be less than that specified for the inner cage in the table,An inner and outer cage plus quadrant mats in accordance with Fig. 2,orAn inner and outer cage plus an elliptical cag
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC76M2014STANDARDSPECIFICATIONFORREINFORCEDCONCRETECULVERTSTORMDRAINANDSEWERPIPE40METRIC41 钢筋混凝土 涵洞

链接地址:http://www.mydoc123.com/p-508291.html