1、Designation: C 764 06aStandard Specification forMineral Fiber Loose-Fill Thermal Insulation1This standard is issued under the fixed designation C 764; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A num
2、ber in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification covers the composition and physicalpr
3、operties of nodulated mineral fiber thermal insulation for usein attics or enclosed spaces in housing and other framedbuildings.1.2 The values stated in inch-pound units are to be regardedas the standard. The values in parentheses are provided forinformation only.1.3 This standard does not purport t
4、o address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2B 152/B
5、152M Specification for Copper Sheet, Strip, Plate,and Rolled BarC 168 Terminology Relating to Thermal InsulationC 177 Test Method for Steady-State Heat Flux Measure-ments and Thermal Transmission Properties by Means ofthe Guarded-Hot-Plate ApparatusC 390 Practice for Sampling and Acceptance of Therm
6、alInsulation LotsC 518 Test Method for Steady-State Thermal TransmissionProperties by Means of the Heat Flow Meter ApparatusC 687 Practice for Determination of Thermal Resistance ofLoose-Fill Building InsulationC 1104/C 1104M Test Method for Determining the WaterVapor Sorption of Unfaced Mineral Fib
7、er InsulationC 1304 Test Method for Assessing the Odor Emission ofThermal Insulation MaterialsC 1338 Test Method for Determining Fungi Resistance ofInsulation Materials and FacingsC 1363 Test Method for Thermal Performance of BuildingMaterials and Envelope Assemblies by Means of a HotBox ApparatusC
8、1374 Test Method for Determination of Installed Thick-ness of Pneumatically Applied Loose-Fill Building Insula-tionC 1574 Guide for Determining Blown Density of Pneumati-cally Applied Loose-Fill Mineral Fiber Thermal InsulationE 136 Test Method for Behavior of Materials in a VerticalTube Furnace at
9、750CE 970 Test Method for Critical Radiant Flux of ExposedAttic Floor Insulation Using a Radiant Heat Energy SourceG1 Practice for Preparing, Cleaning, and Evaluating Cor-rosion Test Specimens3. Terminology3.1 DefinitionsFor definitions of terms used in this speci-fication, refer to Terminology C 16
10、8.3.2 Definitions of Terms Specific to This Standard:3.2.1 settled densityThe mass per unit volume of aloose-fill insulation after which time or forces, or both, haveexerted their effect upon thickness.4. Classification4.1 The nodulated mineral fiber thermal insulation shall beof the following types
11、 and classes:4.1.1 Type IPneumatic application.4.1.2 Type IIPoured application.5. Ordering Information5.1 Both types of nodulated mineral fiber thermal insulationare intended for use as thermal insulation in open spaces, suchas attics and enclosed spaces, such as walls, in housing andbuildings at am
12、bient temperatures. Type I is used for pneumaticapplication (blown or conveyed by an air stream through a hose1This specification is under the jurisdiction of ASTM Committee C16 onThermal Insulation and is the direct responsibility of Subcommittee C16.23 onBlanket and Loose Fill Insulation.Current e
13、dition approved Nov. 15, 2006. Published November 2006. Originallyapproved 1973. Last previous edition approved in 2006 as C 764 06.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume inform
14、ation, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.and discharged over the area to be insulated). Type II is usedfor application by pouring in place.6. Materials and
15、 Manufacture6.1 Basic MaterialThe basic material shall be fibers madefrom mineral substances such as rock, slag, or glass processedfrom the molten state into an incombustible fibrous form.6.2 ManufactureThe fibers shall be mechanically pro-cessed into nodules, and are permitted to be treated to prov
16、ideimproved processing and handling characteristics suitable forinstallation by pouring or pneumatic applications.7. Physical Properties7.1 Thermal CharacteristicsThe standard thermal resis-tance values normally recommended for open application areexpressed in Fhft2/Btu (Km2/W). Typical values are s
17、hownin Table 1. R values others than those listed in Table 1 shall beas agreed upon between the supplier and the purchaser. Thethermal resistance R for the average of any (four) randomlyselected samples shall not be more than 5 % below themutually agreed upon R value when tested in accordance with12
18、.2, nor shall any single specimen be more than 10 % belowthe mutually agreed upon R value.7.2 Critical Radiant FluxMineral fiber loose fill whentested in accordance with 12.3 shall have a critical radiantflux-flame propagation resistance $0.12 W/cm2(.11 Btu/ft2s).7.3 Combustion CharacteristicsMinera
19、l fiber loose fillwhen tested in accordance with 12.4 shall not have a recordedtemperature rise of more than 54F (30C); shall have noflaming after the first 30 s; and, if the specimen weight lossexceeds 50 % during the test, the recorded temperature of thespecimen during the test shall not rise abov
20、e the furnace airtemperature at the beginning of the test, and there shall be noflaming of the specimen.7.4 Water Vapor SorptionThe water vapor sorption of theinsulation shall not be more than 5 % by weight when tested inaccordance with 12.5.7.5 Odor EmissionA detectable odor of a strong objec-tiona
21、ble nature recorded by more than two of the five panelmembers shall constitute rejection of the material when testedin accordance with 12.6.7.6 CorrosivenessWhen tested in accordance with 12.7,the metal plates that are in contact with the insulation shallshow no corrosion greater than the comparativ
22、e plates that arein contact with sterile cotton that has been tested in the samemanner.7.7 Fungi ResistanceWhen tested in accordance with12.8, the insulation shall have growth no greater than thatobserved on the white birch tongue depressor comparativematerial.8. Other Requirements8.1 Qualification
23、RequirementsThe following require-ments are generally emphasized for purposes of initial materialproduct requirements:8.1.1 Thermal resistance,8.1.2 Critical radiant flux,8.1.3 Combustion characteristics,8.1.4 Water vapor sorption,8.1.5 Odor emission,8.1.6 Corrosiveness, and8.1.7 Fungi Resistance.8.
24、2 Inspection RequirementsThe following requirementsare generally emphasized for purposes of acceptance samplingof lots of qualified thermal insulation:8.2.1 Minimum bag weight, and8.2.2 Workmanship.9. Workmanship9.1 Mineral fiber nodulated insulation shall be free offoreign materials and shall be cl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC7642006ASTANDARDSPECIFICATIONFORMINERALFIBERLOOSEFILLTHERMALINSULATION 疏松 填充 矿物纤维 隔热材料 标准规范 PDF

链接地址:http://www.mydoc123.com/p-508269.html