ASTM C739-2017 Standard Specification for Cellulosic Fiber Loose-Fill Thermal Insulation《纤维素纤维松散隔热材料的标准规格》.pdf
《ASTM C739-2017 Standard Specification for Cellulosic Fiber Loose-Fill Thermal Insulation《纤维素纤维松散隔热材料的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C739-2017 Standard Specification for Cellulosic Fiber Loose-Fill Thermal Insulation《纤维素纤维松散隔热材料的标准规格》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C739 11C739 17Standard Specification forCellulosic Fiber Loose-Fill Thermal Insulation1This standard is issued under the fixed designation C739; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision
2、. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This specification covers the composition and
3、 physical requirements of chemically treated, recycled cellulosic fiber loose-filltype thermal insulation for use in attics or enclosed spaces in housing, and other framed buildings within the ambient temperaturerange from 45from 45 to 90C by pneumatic or pouring application.While products that comp
4、ly with this specification are usedin various constructions, they are adaptable primarily, but not exclusively, to wood joist, rafters, and stud construction.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.3 This standar
5、d does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.1.4 This international standard w
6、as developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced
7、 Documents2.1 ASTM Standards:2B152/B152M Specification for Copper Sheet, Strip, Plate, and Rolled BarC168 Terminology Relating to Thermal InsulationC177 Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of theGuarded-Hot-Plate ApparatusC518 Test Method
8、for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter ApparatusC687 Practice for Determination of Thermal Resistance of Loose-Fill Building InsulationC1114 Test Method for Steady-State Thermal Transmission Properties by Means of the Thin-Heater ApparatusC1338 Test Method f
9、or Determining Fungi Resistance of Insulation Materials and FacingsC1363 Test Method for Thermal Performance of Building Materials and EnvelopeAssemblies by Means of a Hot BoxApparatusC1374 Test Method for Determination of Installed Thickness of Pneumatically Applied Loose-Fill Building InsulationC1
10、485 Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using an Electric Radiant Heat Energy SourceE177 Practice for Use of the Terms Precision and Bias in ASTM Test MethodsE691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test MethodE970 Test
11、 Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source3. Terminology3.1 DefinitionsFor definitions of terms used in this specification, see Terminology C168.3.2 Definitions of Terms Specific to This Standard:3.2.1 attican enclosed space between the roo
12、f and ceiling of the occupied part of a building.3.2.2 critical radiant fluxthe level of incident radiant heat energy on the attic floor insulation system at the most distantflame-out point (W/cm2).1 This specification is under the jurisdiction ofASTM Committee C16 on Thermal Insulation and is the d
13、irect responsibility of Subcommittee C16.23 on Blanket and LooseFill Insulation.Current edition approved April 1, 2011June 1, 2017. Published May 2011August 2017. Originally approved 1973. Last previous edition approved 20082011 asC739 08.C739 11. DOI: 10.1520/C0739-11.10.1520/C0739-17.2 For referen
14、cedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the
15、user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard
16、 as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14. Materials and Manufacture4.1 The basic material shall be recycled cellulosic fiber made from selected paper, paperboard
17、 stock, or ground wood stock,excluding contaminated materials, which may reasonably be expected to be retained in the finished product. Suitable chemicalsare introduced to provide properties such as flame resistance, processing, and handling characteristics.4.2 The basic material may be processed in
18、to a form suitable for installation by pneumatic or pouring methods.5. Physical and Chemical Properties5.1 Design DensityThe design density shall be determined in accordance with Section 8. Report all units in kg/m3.5.1.1 Design density is not a basis for acceptance or rejection.5.2 CorrosivenessThe
19、 loose-fill insulation material shall be tested for corrosiveness as specified in Section 9. The compositionof the insulation material shall be such that after testing, no perforation of the 3-mil (76-m) metal specimens shall be evident whenthe specimens are observed over a 40-W appliance light bulb
20、. Notches extending into the coupon 3 mm or less from any edge shallbe ignored.5.3 Critical Radiant FluxWhen tested in accordance with Section 10, the critical radiant flux shall be equal to greater than 0.12 W/cm2. All values shall be reported to two significant digits.5.4 Fungi ResistanceThe loose
21、-fill insulation material shall be tested and shall pass fungi resistance as specified in Section11. If the growth on two or more of the replicate test items is greater than that on the comparative item, the test item shall beconsidered to fail.NOTE 1If the manufacturing claims the insulation kills
22、or controls insects or rodents, or both, the product must be registered as a pesticide under theFederal Insecticide, Fungicide and Rodentic Act, as amended, and must also be registered in accordance with state pesticide statutes.5.5 Moisture Vapor SorptionMoisture gain in the insulation shall be no
23、more than 15 % by weight when tested in accordancewith Section 12.5.6 Odor EmissionAny sample producing a detectable odor that is classified as objectionable and strong or very strong bymore than two panel members shall be considered to have failed the test when tested in accordance with Section 13.
24、5.7 Smoldering CombustionWhen tested in accordance with the smoldering combustion test method in Section 14, theinsulation shall show no evidence of flaming and a weight loss no greater than 15 %.5.8 Thermal ResistanceThe standard thermal resistance values normally recommended for open application a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC7392017STANDARDSPECIFICATIONFORCELLULOSICFIBERLOOSEFILLTHERMALINSULATION 纤维素 纤维 松散 隔热材料 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-508181.html