ASTM C739-2011 Standard Specification for Cellulosic Fiber Loose-Fill Thermal Insulation《纤维素纤维的松散填充隔热材料标准规格》.pdf
《ASTM C739-2011 Standard Specification for Cellulosic Fiber Loose-Fill Thermal Insulation《纤维素纤维的松散填充隔热材料标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C739-2011 Standard Specification for Cellulosic Fiber Loose-Fill Thermal Insulation《纤维素纤维的松散填充隔热材料标准规格》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C739 11Standard Specification forCellulosic Fiber Loose-Fill Thermal Insulation1This standard is issued under the fixed designation C739; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A num
2、ber in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification covers the composition and physicalreq
3、uirements of chemically treated, recycled cellulosic fiberloose-fill type thermal insulation for use in attics or enclosedspaces in housing, and other framed buildings within theambient temperature range from 45 to 90C by pneumatic orpouring application. While products that comply with thisspecifica
4、tion are used in various constructions, they are adapt-able primarily, but not exclusively, to wood joist, rafters, andstud construction.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to a
5、ddress all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2B152/B152M
6、Specification for Copper Sheet, Strip, Plate,and Rolled BarC168 Terminology Relating to Thermal InsulationC177 Test Method for Steady-State Heat Flux Measure-ments and Thermal Transmission Properties by Means ofthe Guarded-Hot-Plate ApparatusC518 Test Method for Steady-State Thermal TransmissionProp
7、erties by Means of the Heat Flow Meter ApparatusC687 Practice for Determination of Thermal Resistance ofLoose-Fill Building InsulationC1114 Test Method for Steady-State Thermal TransmissionProperties by Means of the Thin-Heater ApparatusC1338 Test Method for Determining Fungi Resistance ofInsulation
8、 Materials and FacingsC1363 Test Method for Thermal Performance of BuildingMaterials and Envelope Assemblies by Means of a HotBox ApparatusC1374 Test Method for Determination of Installed Thick-ness of Pneumatically Applied Loose-Fill Building Insula-tionC1485 Test Method for Critical Radiant Flux o
9、f ExposedAttic Floor Insulation Using an Electric Radiant HeatEnergy SourceE177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE970 Test Method for Critical Radiant Flux of ExposedAtt
10、ic Floor Insulation Using a Radiant Heat Energy Source3. Terminology3.1 DefinitionsFor definitions of terms used in this speci-fication, see Terminology C168.3.2 Definitions of Terms Specific to This Standard:3.2.1 attican enclosed space between the roof and ceilingof the occupied part of a building
11、.3.2.2 critical radiant fluxthe level of incident radiant heatenergy on the attic floor insulation system at the most distantflame-out point (W/cm2).4. Materials and Manufacture4.1 The basic material shall be recycled cellulosic fibermade from selected paper, paperboard stock, or ground woodstock, e
12、xcluding contaminated materials, which may reason-ably be expected to be retained in the finished product. Suitablechemicals are introduced to provide properties such as flameresistance, processing, and handling characteristics.1This specification is under the jurisdiction of ASTM Committee C16 onTh
13、ermal Insulation and is the direct responsibility of Subcommittee C16.23 onBlanket and Loose Fill Insulation.Current edition approved April 1, 2011. Published May 2011. Originallyapproved 1973. Last previous edition approved 2008 as C739 08. DOI: 10.1520/C0739-11.2For referenced ASTM standards, visi
14、t the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-29
15、59, United States.4.2 The basic material may be processed into a formsuitable for installation by pneumatic or pouring methods.5. Physical and Chemical Properties5.1 Design DensityThe design density shall be deter-mined in accordance with Section 8. Report all units in kg/m3.5.1.1 Design density is
16、not a basis for acceptance orrejection.5.2 CorrosivenessThe loose-fill insulation material shallbe tested for corrosiveness as specified in Section 9. Thecomposition of the insulation material shall be such that aftertesting, no perforation of the 3-mil (76-m) metal specimensshall be evident when th
17、e specimens are observed over a 40-Wappliance light bulb. Notches extending into the coupon 3 mmor less from any edge shall be ignored.5.3 Critical Radiant FluxWhen tested in accordance withSection 10, the critical radiant flux shall be equal to greaterthan 0.12 W/cm2.All values shall be reported to
18、 two significantdigits.5.4 Fungi ResistanceThe loose-fill insulation materialshall be tested and shall pass fungi resistance as specified inSection 11. If the growth on two or more of the replicate testitems is greater than that on the comparative item, the test itemshall be considered to fail.NOTE
19、1If the manufacturing claims the insulation kills or controlsinsects or rodents, or both, the product must be registered as a pesticideunder the Federal Insecticide, Fungicide and Rodentic Act, as amended,and must also be registered in accordance with state pesticide statutes.5.5 Moisture Vapor Sorp
20、tionMoisture gain in the insula-tion shall be no more than 15 % by weight when tested inaccordance with Section 12.5.6 Odor EmissionAny sample producing a detectableodor that is classified as objectionable and strong or very strongby more than two panel members shall be considered to havefailed the
21、test when tested in accordance with Section 13.5.7 Smoldering CombustionWhen tested in accordancewith the smoldering combustion test method in Section 14, theinsulation shall show no evidence of flaming and a weight lossno greater than 15 %.5.8 Thermal ResistanceThe standard thermal resistancevalues
22、 normally recommended for open application are: 2.3,3.4., 3.9, 5.3, 6.7, and 8.6 and are expressed in Km2/W . Thethermal resistance R for the average of any (four) randomlyselected specimens shall not be more than 5 % below the listedR value when tested in accordance with Section 15. R valuesother t
23、han those listed shall be as agreed upon between thesupplier and the purchaser.6. Workmanship, Finish, and Appearance6.1 The product shall be free of extraneous foreign materialssuch as metals and glass that will adversely affect the perfor-mance in service.TEST METHODS7. Summary7.1 The following te
24、sts shall be conducted on loose-fillcellulosic insulation at the measured design density: moisturevapor sorption, smoldering combustion, and thermal resis-tance.NOTE 2The importance of an insulations product to maintain its fireretardant characteristics is recognized. A task group in ASTM C16.31 isc
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC7392011STANDARDSPECIFICATIONFORCELLULOSICFIBERLOOSEFILLTHERMALINSULATION 纤维素 纤维 松散 填充 隔热材料 标准 规格

链接地址:http://www.mydoc123.com/p-508180.html