《ASTM C687-2007 Standard Practice for Determination of Thermal Resistance of Loose-Fill Building Insulation《松填建筑绝热材料隔热性能的测定用标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C687-2007 Standard Practice for Determination of Thermal Resistance of Loose-Fill Building Insulation《松填建筑绝热材料隔热性能的测定用标准实施规程》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 687 07Standard Practice forDetermination of Thermal Resistance of Loose-Fill BuildingInsulation1This standard is issued under the fixed designation C 687; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of l
2、ast revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice presents a laboratory guide to determinethe thermal resistance of loose-fill building insulations at mea
3、ntemperatures between 20 and 55C (4 to 131F).1.2 This practice applies to a wide variety of loose-fillthermal insulation products including fibrous glass, rock/slagwool, or cellulosic fiber materials; granular types includingvermiculite and perlite; pelletized products; and any otherinsulation mater
4、ial installed pneumatically or poured in place.It does not apply to products that change their character afterinstallation either by chemical reaction or the application ofbinders or adhesives, nor does it consider the effects ofstructures, containments, facings, or air films.1.3 Since this practice
5、 is designed for reproducible productcomparison, it measures the thermal resistance of an insulationmaterial which has been preconditioned to a relatively drystate. Consideration of changes of thermal performance of ahygroscopic insulation by sorption of water is beyond thescope of this practice.1.4
6、 The sample preparation techniques outlined in thispractice do not cover the characterization of loose-fill materialsintended for enclosed applications. For those applications, aseparate sample preparation technique that simulates the in-stalled condition will be required. However, even for thoseapp
7、lications, some other aspects of this practice are applicable.1.5 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is t
8、heresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 167 Test Methods for Thickness and Density of Blanketor Batt Thermal InsulationsC 1
9、68 Terminology Relating to Thermal InsulationC 177 Test Method for Steady-State Heat Flux Measure-ments and Thermal Transmission Properties by Means ofthe Guarded-Hot-Plate ApparatusC 518 Test Method for Steady-State Thermal TransmissionProperties by Means of the Heat Flow Meter ApparatusC 653 Guide
10、 for Determination of the Thermal Resistanceof Low-Density Blanket-Type Mineral Fiber InsulationC 739 Specification for Cellulosic Fiber Loose-Fill ThermalInsulationC 1045 Practice for Calculating Thermal TransmissionProperties Under Steady-State ConditionsC 1114 Test Method for Steady-State Thermal
11、 TransmissionProperties by Means of the Thin-Heater ApparatusC 1363 Test Method for Thermal Performance of BuildingMaterials and Envelope Assemblies by Means of a HotBox ApparatusC 1373 Practice for Determination of Thermal Resistanceof Attic Insulation Systems Under Simulated Winter Con-ditions3. T
12、erminology3.1 Unless otherwise stated, the terms and definitions foundin Terminology C 168 are applicable herein.4. Significance and Use4.1 The thermal resistance, R, of an insulation is used todescribe its thermal performance.4.2 The thermal resistance of an insulation is related to thedensity and
13、thickness of the insulation. It is desirable to obtain1This practice is under the jurisdiction of ASTM Committee C16 on ThermalInsulation and is the direct responsibility of Subcommittee C16.30 on ThermalMeasurement.Current edition approved Nov. 15, 2007. Published January 2008. Originallyapproved i
14、n 1971. Last previous edition approved in 2005 as C 687 05.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1C
15、opyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.test data on thermal resistances at thicknesses and densitiesrelated to the end uses of the product.4.3 In normal use, the thickness of these products rangefrom less than 100 mm (4 in.) t
16、o greater than 500 mm (20 in.).Installed densities depend upon the product type, the installedthickness, the installation equipment used, the installationtechniques, and the geometry of the insulated space.4.4 Loose-fill insulations provide coverage information us-ing densities selected by manufactu
17、rers to represent the productsettled densities. Generally, it is necessary to know the productthermal performance at a representative density. Some cover-age charts utilize multiple densities to show that greaterthickness installations usually result in higher installed densi-ties. The use of multip
18、le densities can be detected from thecoverage chart by calculating the density for several differentthermal resistance levels. (The density for a given thermalresistance can be calculated from the coverage chart bydividing the minimum mass per unit area by the minimumthickness.) If the calculated de
19、nsities are significantly differentat different thermal resistances, the multiple density strategyhas been used.4.5 When applicable specifications or codes do not specifythe nominal thermal resistance level to be used for comparisonpurposes, a recommended practice is to use the Rsi(met-ric) = 3.3 m2
20、K/W (RIP=19hft2F/Btu) label density andthickness for that measurement.4.6 If the density for test purposes is not available from thecoverage chart, a test density shall be established by use ofapplicable specifications and codes or, if none apply, agreementbetween the requesting body and the testing
21、 organization.4.7 Generally, thin sections of these materials are notuniform. Thus, the test thickness must be greater than or equalto the products representative thickness if the results are to beconsistent and typical of use.NOTE 1The representative thickness is specific for each product andis det
22、ermined by running a series of tests in which the density is heldconstant but the thickness is increased. The representative thickness isdefined here as that thickness above which there is no more than a 2 %change in the resistivity of the product. The representative thickness is afunction of produc
23、t blown density. In general, as the density decreases, therepresentative thickness increases. Fortunately, most products are de-signed to be blown over a small range of densities. This limited rangeyields a range of representative thicknesses between 100 to 200 mm (4 to8 in.) for most products. To s
24、implify the process for this Practice, therepresentative thickness for the C 687 tests shall be determined at themidpoint of the blown density range. Once this is accomplished, allthermal testing on this product is conducted at a thickness that is greateror equal to the representative thickness.4.7.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC6872007STANDARDPRACTICEFORDETERMINATIONOFTHERMALRESISTANCEOFLOOSEFILLBUILDINGINSULATION 建筑 绝热材料

链接地址:http://www.mydoc123.com/p-508017.html