《ASTM C686-1990(2007) Standard Test Method for Parting Strength of Mineral Fiber Batt- and Blanket-Type Insulation《矿质纤维绒及毡式绝热材料的分离强度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C686-1990(2007) Standard Test Method for Parting Strength of Mineral Fiber Batt- and Blanket-Type Insulation《矿质纤维绒及毡式绝热材料的分离强度的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 686 90 (Reapproved 2007)Standard Test Method forParting Strength of Mineral Fiber Batt- and Blanket-TypeInsulation1This standard is issued under the fixed designation C 686; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revi
2、sion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers evaluation of strength in tensionon mineral fiber batt- and blanket-type in
3、sulation products. It isuseful for determining the comparative tensile properties ofthese products, specimens of which cannot be held by the moreconventional clamp-type grips. This is a quality controlmethod, and the results should not be used for design purposes.It is not normally used for board-ty
4、pe products.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.
5、Referenced Documents2.1 ASTM Standards:2C 167 Test Methods for Thickness and Density of Blanketor Batt Thermal InsulationsE 171 Specification for Atmospheres for Conditioning andTesting Flexible Barrier MaterialsE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Te
6、st Method3. Significance and Use3.1 Tensile strength is a fundamental property associatedwith mineral fiber manufacture since it is influenced by thetype of fiber, the deposition of fiber, the type and the amount ofbonding agent, and the method of curing the resin to form abonded insulation product.
7、 The test is an indication of productintegrity and the ability of the product to be successfullyhandled and applied in the field.4. Apparatus4.1 Constant Rate of Traverse Tension Test Unit of 50-lbf(223-N) capacity calibrated in increments of 0.1 lbf (0.4 N) andhaving a moving head speed of 12 in. (
8、305 mm)/min orequivalent (see Fig. 1).4.2 Post-Type Grips with 1-in. (25.4-mm) diameter rods(see Fig. 2).4.3 Die for cutting specimens (see Fig. 3). The O-ringspecimen dimensions are 3 by 4.75 in. (76 by 120.6 mm) inoutside diameter, and 1 by 2.75 in. (25 by 69.8 mm) in insidediameter (see Fig. 4).4
9、.4 Balance to weigh to an accuracy of 0.01 g.5. Test Specimen5.1 The test specimen shall consist of the entire O-ring cutfrom the full thickness of the product to be tested.5.2 Specimens shall not be cut from a product that varies inthickness 65 % from normal when tested in accordance withTest Metho
10、d C 167.5.3 No specimen shall be tested that exhibits any obviousdamage in the insulation or that shows delamination within theinsulation thickness.6. Conditioning6.1 Condition the specimens for1hinaroom maintained atatmospheric conditions of 73.4 6 1.8F (23 6 1C) and 50 62 % relative humidity in ac
11、cordance with Specification E 171.7. Procedure7.1 Weigh each specimen to the nearest 0.01 g and recordthe weight.7.2 Attach the post-type grips to the tension test unit andalign the grips in the vertical plane.7.3 Adjust the speed of the moving head to 12 in. (305mm)/min.7.4 Set the stops of the mov
12、ing head until the grips areapproximately14 in. (6.3 mm) apart in the starting position.7.5 Place the specimen on the post-type grip (higher densityside first if it is evident that such exists) so that both posts arewithin the oblong hole of the specimen. The high density sideof the specimen shall b
13、e in contact with the post shield.1This test method is under the jurisdiction ofASTM Committee C16 on ThermalInsulation and is the direct responsibility of Subcommittee C16.32 on MechanicalProperties.Current edition approved May 1, 2007. Published May 2007. Originallypublished as approved in 1971. L
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC68619902007STANDARDTESTMETHODFORPARTINGSTRENGTHOFMINERALFIBERBATTANDBLANKETTYPEINSULATION 纤维 绝热材料

链接地址:http://www.mydoc123.com/p-508013.html