ASTM C636 C636M-2013 Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-In Panels《吸音砖和衬板用金属吊顶系统安装的标准实施规程》.pdf
《ASTM C636 C636M-2013 Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-In Panels《吸音砖和衬板用金属吊顶系统安装的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C636 C636M-2013 Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-In Panels《吸音砖和衬板用金属吊顶系统安装的标准实施规程》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C636/C636M 08C636/C636M 13Standard Practice forInstallation of Metal Ceiling Suspension Systems forAcoustical Tile and Lay-In Panels1This standard is issued under the fixed designation C636/C636M; the number immediately following the designation indicates the yearof original adoption or
2、, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.
3、1 This practice covers the installation of suspension systems for acoustical tile and lay-in panels. It is applicable to contractorswhose services are utilized for installing acoustical ceilings and to other trades if their activities are responsible for interferencewith ceiling components or perfor
4、mance as defined in this recommended practice.1.2 While the practices described in this document have equal application to rated fire-resistive suspension systems, additionalrequirements may have been imposed to obtain the fire endurance classification of particular floor-ceiling or roof-ceilingasse
5、mblies. These details should be obtained from the manufacturers.1.3 Similarly, additional detailing may be necessary to meet sound attenuation requirements when ceiling plenums extend overcontiguous rooms. These, too, should be obtained from the manufacturer of the acoustical material employed.1.4 T
6、he values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in eachsystem may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from thetwo systems may result in non-conformance with th
7、e standard.1.5 While many of the practices described in this practice have application to the installation of metal suspension systems inexterior environments, the specific design of exterior ceiling installations requires the review and approval of the architect orengineer, or both, who are respons
8、ible for the construction of the building or modifications to an existing building. Whilerecommendations from the manufacturer should be solicited, it remains the final responsibility of the architect/engineer to ensureproper application of the materials in question.1.6 This standard does not purpor
9、t to address of the safety concerns, if any, associated with its use. It is the responsibility ofthe user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Installation of Components2.1 Hangers:2.1.1 Where a
10、coustical ceilings are suspended from a structure of wood construction, attach hangers with suitable mechanicaldevices either to the bottom edge of the wood joists or to the vertical face of the wood joists near the bottom edge. Holding powertests certified by the manufacturer must be available on r
11、equest for bottom edge attachment devices.2.1.2 Where acoustical ceilings are suspended from a structure of concrete construction, mount hangers using cast-in-placehanger wires, hanger inserts, or other hanger attachment devices whose suitability has been demonstrated by standard constructionpractic
12、e or by certified test data.2.1.3 Space hangers for carrying channels or main runners 4 ft 0 in. 1200 mm on centers. If local situations allow greatercenter distances between hangers, reduce the load-carrying capacity of the ceiling suspension system commensurate with the actualcenter-to-center hang
13、er distances used. If local situations allow lesser center distances between hangers, increase the load-carryingcapacity of the ceiling suspension system commensurate with the actual center-to-center hanger distances used.2.1.4 Each suspension wire shall not hang more than one in six out of plumb un
14、less a countersloping wire or horizontal bracingis provided. See Fig. 1 for allowable countersloping methods. Suspension wires should not press against ducts or pipes.1 This practice is under the jurisdiction of ASTM Committee E33 on Building and Environmental Acoustics and is the direct responsibil
15、ity of Subcommittee E33.04 onApplication of Acoustical Materials and Systems.Current edition approved April 1, 2008April 1, 2013. Published April 2008May 2013. Originally approved in 1969. Last previous edition approved in 20062008 asC636 06.C636 08. DOI: 10.1520/C0636_C0636M-08.10.1520/C0636_C0636M
16、-13.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior
17、 editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1FIG. 1 Allowable Countersloping MethodsC636/
18、C636M 1322.1.5 Hangers formed from galvanized sheet metal stock shall be suitable for suspending carrying channels or main runnersfrom an existing structure provided that the hangers do not yield, twist, or undergo other objectionable movement.2.1.6 Wire hangers for suspending carrying channels or m
19、ain runners from an existing structure shall be prepared from aminimum of No. 12-gage 2.70 mm galvanized, soft-annealed, mild steel wire.2.1.7 In some installations hanger wires are secured to special attachment devices that support the carrying channels or mainrunners. Such attachment devices shall
20、 have certified load test data from an independent test laboratory and shall be capable ofcarrying five times the design load.2.2 Carrying Channels:2.2.1 Install the carrying channels so that they are all level to within 18 in. in 12 ft 3.2 mm in 3600 mm.2.2.2 Perform leveling with the supporting ha
21、ngers taut to prevent any subsequent downward movement of the carryingchannels when the ceiling loads are imposed.2.2.3 Local kinks or bends shall not be made in hanger wires as a means of leveling carrying channels.2.2.4 In installations where hanger wires are wrapped around carrying channels, the
22、wire loops shall be tightly formed to preventany vertical movement or rotation of the member within the loop.2.3 Main Runners:2.3.1 Install main runners so that they are all level to within 14 in. in 10 ft 6 mm in 3000 mm. Determine evaluation oflevelness from measurements taken below hanger points.
23、 Make the measurements after completion of the ceiling installations butprior to building occupancy.2.3.2 Where main runners are supported directly by hangers, perform leveling with the supporting hanger taut to prevent anysubsequent downward movement of the main runners when the ceiling loads are i
24、mposed.2.3.3 Local kinks or bends shall not be made in hanger wires as a means of leveling main runners.2.3.4 In installations where hanger wires are wrapped through or around main runners, the wire loops shall be tightly wrappedand sharply bent to prevent any vertical movement or rotation of the me
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC636C636M2013STANDARDPRACTICEFORINSTALLATIONOFMETALCEILINGSUSPENSIONSYSTEMSFORACOUSTICALTILEANDLAYINPANELS

链接地址:http://www.mydoc123.com/p-507850.html