ASTM C610-2007 Standard Specification for Molded Expanded Perlite Block and Pipe Thermal Insulation《模制膨胀珍珠岩块材和管形隔热材料的标准规范》.pdf
《ASTM C610-2007 Standard Specification for Molded Expanded Perlite Block and Pipe Thermal Insulation《模制膨胀珍珠岩块材和管形隔热材料的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM C610-2007 Standard Specification for Molded Expanded Perlite Block and Pipe Thermal Insulation《模制膨胀珍珠岩块材和管形隔热材料的标准规范》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 610 07Standard Specification forMolded Expanded Perlite Block and Pipe ThermalInsulation1This standard is issued under the fixed designation C 610; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last rev
2、ision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification covers molded expanded pe
3、rliteblock, fittings, and pipe thermal insulation intended for use onsurfaces with temperatures between 80 to 1200F (27 to649C).1.2 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.1.3 When the installation or use of the
4、rmal insulationmaterials, accessories, and systems may pose safety or healthproblems, the manufacturer shall provide the user appropriatecurrent information regarding any known problems associatedwith the recommended use of the companys products and shallalso recommend protective measures to be empl
5、oyed in theirsafe utilization. The following safety caveat applies only to thetest methods portion of this specification: This standard doesnot purport to address all of the safety concerns, if any,associated with its use. It is the responsibility of the user of thisstandard to establish appropriate
6、 safety and health practicesand determine the applicability of regulatory limitations priorto use.2. Referenced Documents2.1 ASTM Standards:2C 165 Test Method for Measuring Compressive Propertiesof Thermal InsulationsC 168 Terminology Relating to Thermal InsulationC 177 Test Method for Steady-State
7、Heat Flux Measure-ments and Thermal Transmission Properties by Means ofthe Guarded-Hot-Plate ApparatusC 203 Test Methods for Breaking Load and Flexural Prop-erties of Block-Type Thermal InsulationC 302 Test Method for Density and Dimensions of Pre-formed Pipe-Covering-Type Thermal InsulationC 303 Te
8、st Method for Dimensions and Density of Pre-formed Block and BoardType Thermal InsulationC 335 Test Method for Steady-State Heat Transfer Proper-ties of Pipe InsulationC 356 Test Method for Linear Shrinkage of PreformedHigh-Temperature Thermal Insulation Subjected to Soak-ing HeatC 390 Practice for
9、Sampling and Acceptance of ThermalInsulation LotsC411 Test Method for Hot-Surface Performance of High-Temperature Thermal InsulationC 421 Test Method for Tumbling Friability of PreformedBlock-Type Thermal InsulationC 450 Practice for Fabrication of Thermal Insulating FittingCovers for NPS Piping, an
10、d Vessel LaggingC 518 Test Method for Steady-State Thermal TransmissionProperties by Means of the Heat Flow Meter ApparatusC 585 Practice for Inner and Outer Diameters of RigidThermal Insulation for Nominal Sizes of Pipe and Tubing(NPS System)C 692 Test Method for Evaluating the Influence of Thermal
11、Insulations on External Stress Corrosion Cracking Ten-dency of Austenitic Stainless SteelC 795 Specification for Thermal Insulation for Use in Con-tact with Austenitic Stainless SteelC 1045 Practice for Calculating Thermal TransmissionProperties Under Steady-State ConditionsC 1058 Practice for Selec
12、ting Temperatures for Evaluatingand Reporting Thermal Properties of Thermal InsulationE84 Test Method for Surface Burning Characteristics ofBuilding Materials3. Terminology3.1 GeneralTerminology C 168 shall be considered asapplying to the terms used in this specification.3.2 Definitions of Terms Spe
13、cific to This Standard:1This specification is under the jurisdiction of ASTM Committee C16 onThermal Insulation and is the direct responsibility of Subcommittee C16.20 onHomogeneous Inorganic Thermal Insulations.Current edition approved April 15, 2007. Published April 2007. Originallyapproved in 196
14、7. Last previous edition approved in 2005 as C 610 05.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyri
15、ght ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.1 compositionmolded expanded perlite block, fitting,and pipe thermal insulation shall be composed principally ofexpanded perlite and silicate binders. It may also containreinforcing fibers
16、.4. Standard Shapes, Sizes, and Dimensions4.1 Molded expanded perlite block, fitting, and pipe thermalinsulation shall be as follows:4.1.1 BlockBlock shall be furnished in lengths of either36 or 39.37 in. (914 or 1000 mm), widths of 6 in. (152 mm),12 in. (305 mm), 18 in. (457 mm), or 24 in. (610 mm)
17、, and inthickness from 112 to 6 in. (38 to 152 mm) in increments of12in. (13 mm).4.1.2 Pipe InsulationMolded expanded perlite pipe insu-lation shall be supplied either as hollow cylindrical shapes splitin half lengthwise (in a plane including the cylindrical axis) oras curved segments. The pipe insu
18、lation shall be furnished insections or segments in lengths of either 36 or 39.37 in. (914 or1000 mm) to fit standard sizes of pipe and tubing, and innominal thickness from 1 to 4 in. (25 to 102 mm) in12-in.(13-mm) increments. Inner and outer diameters of multilayerconstruction may be specified. Inn
19、er and outer diameters shallbe in accordance with those standard dimensions specified inPractice C 585. Since outside diameter tolerances may bedifferent under individual manufacturing processes, it may benecessary to have pipe insulation furnished in two or morelayers nested by the manufacturer. Th
20、e purchaser shall consultthe manufacturer for specific requirements.4.1.3 FittingsMolded (expanded insulation fittings shallconform to the inner and outer diameters in accordance withthose standard dimensions specified in Practice C 585. Miteredfittings shall be in accordance with Practice C 450.5.
21、Dimensional Tolerances5.1 GeneralThe average tolerances for length, width, andthickness shall comply with the requirements shown in Table 1.5.2 Pipe InsulationThe following additional tolerancesapply to perlite pipe insulation supplied as half sections:5.2.1 Fit and ClosureWhen fitted to the appropr
22、iate sizepipe, the longitudinal seam of the pipe insulation shall close towithin116 in. (1.6 mm) along the entire length of the section.5.2.2 ConcentricityThe inner bore of the pipe insulationshall be concentric with the outer cylindrical surface. Thedeviation from concentricity shall not exceed18 i
23、n. (3.2 mm)or 5 % of the wall thickness, whichever is greater.5.2.3 Half-Section BalanceThe plane formed by the splitbetween half sections shall include the cylindrical axis. Devia-tion of the split plane from the cylinder axis over the 36 or39.37-in. (914 or 1000-mm) length shall not exceed18 in. (
24、3.2mm).6. Workmanship, Finish, and Appearance6.1 Since some requirements for this material are not easilydefined by a numerical value, the insulation shall not havevisible defects that will adversely affect its service qualities.7. Physical Requirements7.1 The insulation shall conform to the physica
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC6102007STANDARDSPECIFICATIONFORMOLDEDEXPANDEDPERLITEBLOCKANDPIPETHERMALINSULATION 膨胀 珍珠岩 隔热材料 标准规范

链接地址:http://www.mydoc123.com/p-507751.html