1、Designation: C547 15Standard Specification forMineral Fiber Pipe Insulation1This standard is issued under the fixed designation C547; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parenthese
2、s indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This specification covers mineral fiber insulation pro-duced to form
3、hollow cylinders for standard pipe and tubingsizes. The mineral fiber pipe insulation may be molded orprecision v-grooved, with one or more walls split longitudi-nally for use on pipe temperatures up to 1400F (760C).1.2 For satisfactory performance, properly installed protec-tive vapor retarders or
4、barriers should be used on sub-ambienttemperature applications to reduce movement of moisturethrough or around the insulation to the colder surface. Failureto use a vapor barrier can lead to insulation and systemdamage. Refer to Practice C921 to aid material selection.1.3 Flexible mineral fiber wrap
5、 products such asperpendicular-oriented fiber insulation rolls, non-precision ormanually scored block or board, or flexible boards or blanketsused as pipe insulation, are not covered by this specification.1.4 The values stated in inch-pound units are to be regardedas standard. The values given in pa
6、rentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.5 For Naval Sea Systems Command (NAVSEA)acceptance, materials must also comply with SupplementalRequirements. See Annex A1 of this standard.1.6 The following safety hazards cavea
7、t applies to the testmethods portion, Section 11, only: This standard does notpurport to address all of the safety concerns, if any, associatedwith its use. It is the responsibility of the user of this standardto establish appropriate safety and health practices anddetermine the applicability of reg
8、ulatory limitations prior touse.2. Referenced Documents2.1 ASTM Standards:2C167 Test Methods for Thickness and Density of Blanket orBatt Thermal InsulationsC168 Terminology Relating to Thermal InsulationC177 Test Method for Steady-State Heat Flux Measure-ments and Thermal Transmission Properties by
9、Means ofthe Guarded-Hot-Plate ApparatusC302 Test Method for Density and Dimensions of Pre-formed Pipe-Covering-Type Thermal InsulationC335/C335M Test Method for Steady-State Heat TransferProperties of Pipe InsulationC356 Test Method for Linear Shrinkage of Preformed High-Temperature Thermal Insulati
10、on Subjected to SoakingHeatC390 Practice for Sampling and Acceptance of ThermalInsulation LotsC411 Test Method for Hot-Surface Performance of High-Temperature Thermal InsulationC447 Practice for Estimating the Maximum Use Tempera-ture of Thermal InsulationsC585 Practice for Inner and Outer Diameters
11、 of ThermalInsulation for Nominal Sizes of Pipe and TubingC795 Specification for Thermal Insulation for Use in Con-tact with Austenitic Stainless SteelC921 Practice for Determining the Properties of JacketingMaterials for Thermal InsulationC1045 Practice for Calculating Thermal Transmission Prop-ert
12、ies Under Steady-State ConditionsC1058/C1058M Practice for Selecting Temperatures forEvaluating and Reporting Thermal Properties of ThermalInsulationC1104/C1104M Test Method for Determining the WaterVapor Sorption of Unfaced Mineral Fiber Insulation1This specification is under the jurisdiction of AS
13、TM Committee C16 onThermal Insulation and is the direct responsibility of Subcommittee C16.20 onHomogeneous Inorganic Thermal Insulations.Current edition approved March 1, 2015. Published April 2015. Originallyapproved in 1964. Last previous edition approved in 2012 as C547 15. DOI:10.1520/C0547-12.
14、2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C
15、700, West Conshohocken, PA 19428-2959. United States1E84 Test Method for Surface Burning Characteristics ofBuilding Materials2.2 Other Standards:UL 723 Tests for Surface Burning of Building Materials3NFPA 255 Method of Tests of Surface Burning Character-istics of Building Materials4CAN/ULC-S102 Stan
16、dard Method of Test for Surface Burn-ing Characteristics of Building Materials and Assemblies53. Terminology3.1 The definitions in Terminology C168 shall apply to theterms used in this specification.3.2 Definitions of Terms Specific to This Standard:3.2.1 moldedrefers to products preformed via a mol
17、dingprocess to yield full-round cylindrical pipe insulation sections.3.2.2 precision v-grooverefers to products fabricated frommachined board via a precision cutting process. Machinedsegments are adhered to a backing to form a full-roundcylindrical pipe insulation section. Due to the precision of th
18、eprocess, the product has no gaps when installed.4. Classification4.1 Products covered by this specification are classifiedaccording to maximum use temperature as follows:4.1.1 Type IMolded, for use to 850F (454C).Grade ARequires no heat-up scheduleGrade BHeat-up schedule is required4.1.2 Type IIMol
19、ded, for use to 1200F (650C).Grade ARequires no heat-up scheduleGrade BHeat-up schedule is required4.1.3 Type IIIPrecision v-groove, for use to 1200F(650C).Grade ARequires no heat-up scheduleGrade BHeat-up schedule is required4.1.4 Type IVMolded, for use to 1000F (538C).Grade ARequires no heat-up sc
20、heduleGrade BHeat-up schedule is required4.1.5 Type VMolded, for use to 1400F (760C)Grade ARequires no heat-up scheduleGrade BHeat-up schedule is requiredNOTE 1Warning: Grade B may not be suitable for applicationsrequiring hot installation capability at the maximum temperature indi-cated. Products h
21、aving a Grade B designation are designed to be used witha heat-up schedule. Failure to use a heat-up schedule with Grade Bproducts may lead to an exothermic reaction. This is dependent onthickness and temperature. Consult the manufacturer or manufacturersliterature for special heat rate consideratio
22、ns.4.2 Binder decomposition at elevated temperature may be alimiting factor in certain applications. Consult the manufac-turer regarding special heat rate considerations.5. Materials and Manufacturer5.1 Composition The mineral fiber insulation for pipesshall be manufactured from mineral substance su
23、ch as rock,slag, or glass, processed from a molten state into fibrous formwith binder. Asbestos shall not be used as an ingredient orcomponent part. Some products may also contain adhesive.5.2 Jackets (Facings)The user of this specification has theoption to specify that the insulation be jacketed.NO
24、TE 2The user is advised that the maximum use temperature offactory-applied facings and adhesives may be lower than the maximumuse temperature of the insulation. The specifier shall ensure that sufficientinsulation thickness is installed so none of these accessory items (facingsand adhesives) are exp
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC5472015STANDARDSPECIFICATIONFORMINERALFIBERPIPEINSULATION 矿物纤维 绝缘 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-466977.html