《ASTM C506M-2012 Standard Specification for Reinforced Concrete Arch Culvert Storm Drain and Sewer Pipe (Metric)《钢筋混凝土制拱形涵洞 雨水道和污水管标准规格(公制)》.pdf》由会员分享,可在线阅读,更多相关《ASTM C506M-2012 Standard Specification for Reinforced Concrete Arch Culvert Storm Drain and Sewer Pipe (Metric)《钢筋混凝土制拱形涵洞 雨水道和污水管标准规格(公制)》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation:C506M11 Designation: C506M 12Standard Specification forReinforced Concrete Arch Culvert, Storm Drain, and SewerPipe (Metric)1This standard is issued under the fixed designation C506M; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specifi
3、cation covers reinforced arch-shaped concrete pipe to be used for the conveyance of sewage, industrial wastes,storm water, and for the construction of culverts.1.2 This specification is the SI companion to Specification C506.NOTE 1This specification is a manufacturing and purchase specification only
4、, and does not include requirements for bedding, backfill, or therelationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of thisproduct depends upon the proper selection of the class of pipe, type of bedding and
5、 backfill, and care that the installation conforms to the constructionspecifications. The owner of the reinforced concrete pipe specified herein is cautioned that he must correlate the field requirements with the class of pipespecified and provide inspection at the construction site.2. Referenced Do
6、cuments2.1 ASTM Standards:2A36/A36M Specification for Carbon Structural SteelA82/A82MSpecification for Steel Wire, Plain, for Concrete ReinforcementA185/A185MSpecification for Steel Welded Wire Reinforcement, Plain, for ConcreteA496/A496MSpecification for Steel Wire, Deformed, for Concrete Reinforce
7、mentA497/A497MSpecification for Steel Welded Wire Reinforcement, Deformed, for ConcreteA615/A615M Specification for Deformed and Plain Carbon-Steel Bars for Concrete ReinforcementA706/A706M Specification for Low-Alloy Steel Deformed and Plain Bars for Concrete ReinforcementA1064/A1064M Specification
8、 for Steel Wire and Welded Wire Reinforcement, Plain and Deformed, for ConcreteC33 Specification for Concrete AggregatesC150 Specification for Portland CementC260 Specification for Air-Entraining Admixtures for ConcreteC309 Specification for Liquid Membrane-Forming Compounds for Curing ConcreteC494/
9、C494M Specification for Chemical Admixtures for ConcreteC497M Test Methods for Concrete Pipe, Manhole Sections, or Tile MetricC595 Specification for Blended Hydraulic CementsC618 Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in ConcreteC822 Terminology Relating to Concr
10、ete Pipe and Related ProductsC989 Specification for Slag Cement for Use in Concrete and MortarsC1017/C1017M Specification for Chemical Admixtures for Use in Producing Flowing ConcreteC1116 Specification for Fiber-Reinforced Concrete and Shotcrete3. Terminology3.1 DefinitionsFor definitions of terms
11、relating to concrete pipe, see Terminology C822.4. Classification4.1 Pipe manufactured according to this specification shall be of three classes identified as Class A-II, A-III, and A-IV. The1This specification is under the jurisdiction of ASTM Committee C13 on Concrete Pipe and is the direct respon
12、sibility of Subcommittee C13.02 on Reinforced Sewerand Culvert Pipe.Current edition approved Feb.May 1, 2011.2012. Published March 2011.June 2012. Originally approved in 1980. Last previous edition approved in 20102011 asC506M10b.C506M 11. DOI: 10.1520/C0506M-112.2For referenced ASTM standards, visi
13、t the ASTM website, www.astm.org, or contact ASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.1This document is not an ASTM standard and is intended only to provide the user of an ASTM stan
14、dard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by AST
15、M is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.strength requirements are prescribed in Table 1.5. Basis of Acceptance5.1 Unless otherwise designated by the owner at the time of, or before p
16、lacing an order, there are two separate and alternativebases of acceptance. Independent of the method of acceptance, the pipe shall be designed to meet both the 0.01-in. crack andultimate strength requirements.5.1.1 Acceptance on Basis of Plant Load Bearing Tests, Material Tests, and Inspection of M
17、anufactured Pipe for Visual Defectsand ImperfectionsAcceptability of the pipe in all diameters and classes produced in accordance with 7.1 or 7.2 shall bedetermined by the results of the three-edge-bearing tests as defined in 11.3.1; by such material tests as are required in accordancewith 6.2, 6.3,
18、 6.5, and 6.6, by an absorption test of the concrete from the wall of the pipe as required in 11.9; and by visualinspection of the finished pipe to determine its conformance with the accepted design and its freedom from defects.5.1.2 Acceptance on the Basis of Material Test and Inspection of Manufac
19、tured Pipe for Defects and ImperfectionsAcceptability of the pipe in all diameters and classes produced in accordance with 7.1 or 7.2 shall be determined by the resultsof such material tests as are required in accordance with 6.2, 6.3, 6.5, and 6.6; by crushing tests on concrete cores or cured concr
20、etecylinders; by an absorption test of the concrete from the wall of the pipe for each mix design that is used on an order; and byinspection of the finished pipe, including amount and placement of reinforcement, to determine its conformance with the accepteddesign and its freedom from defects.5.1.3
21、When agreed upon by the owner and the manufacturer, any portion or any combination of the tests itemized in 5.1.1 or5.1.2 may form the basis of acceptance.5.2 Age for AcceptancePipe shall be considered ready for acceptance when they conform to the requirements as indicated bythe specified tests.TABL
22、E 1 Strength Requirements for Reinforced Concrete PipeAApprox-imateEquivalentRoundSize,mmT,mmMini-mumRise,mmMini-mumSpan,mmf8cBMPaDouble Line ReinforcementCSingle LineReinforcementContinuous BasicReinforcement = AsDAdditional Reinforcement = AsDClass Inner Cage Outer Cage“U ”(Inner Cage)“V ”(Outer C
23、age)A-II A-III A-IV A-II A-III A-IV A-II A-III A-IVDimen-sion,mmA-II A-III A-IVDimen-sion,mmA-II A-III A-IV A-II A-III A-IV375 57 280 460 27.6 27.6 27.6 . . . . . . . . . . . . . . 1.7 2.5 3.6450 63 345 560 27.6 27.6 27.6 . . . . . . . . . . . . . . 2.3 3.0 5.5525 69 395 660 27.6 27.6 27.6 . . . . .
24、 . . . . . . . . . 2.8 3.6 6.1600 75 460 725 27.6 27.6 27.6 . . . . . . 660 . . . 735 . . . 3.4 4.6 6.8750 88 570 920 27.6 27.6 27.6 1.9 2.5 3.8 1.5 1.9 3.0 760 1.9 2.5 3.8 865 1.5 1.9 2.8 3.8 5.1 7.6900 100 675 1110 27.6 27.6 27.6 2.3 3.2 4.6 1.9 2.5 3.6 865 2.3 3.2 4.6 990 1.9 2.5 3.4 4.6 6.3 9.31
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC506M2012STANDARDSPECIFICATIONFORREINFORCEDCONCRETEARCHCULVERTSTORMDRAINANDSEWERPIPEMETRIC 钢筋混凝土

链接地址:http://www.mydoc123.com/p-466844.html