ASTM C25-2011 Standard Test Methods for Chemical Analysis of Limestone Quicklime and Hydrated Lime《石灰石 生石灰和熟石灰化学分析的标准试验方法》.pdf
《ASTM C25-2011 Standard Test Methods for Chemical Analysis of Limestone Quicklime and Hydrated Lime《石灰石 生石灰和熟石灰化学分析的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C25-2011 Standard Test Methods for Chemical Analysis of Limestone Quicklime and Hydrated Lime《石灰石 生石灰和熟石灰化学分析的标准试验方法》.pdf(37页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C25 11Standard Test Methods forChemical Analysis of Limestone, Quicklime, and HydratedLime1This standard is issued under the fixed designation C25; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the year of last revis
2、ion. A number in parentheses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 These test methods cover the chemical analysis
3、ofhigh-calcium and dolomitic limestone, quicklime, and hy-drated lime. These test methods are classified as either standard(preferred) or alternative (optional).1.2 The standard test methods are those that employ classi-cal gravimetric or volumetric analytical procedures and aretypically those requi
4、red for referee analyses where chemicalspecification requirements are an essential part of contractualagreement between buyer and seller.1.3 Alternative or optional test methods are provided forthose who wish to use procedures shorter or more convenientthan the standard methods for the routine deter
5、minations ofcertain constituents. Optional test methods may sometimes bepreferred to the standard test methods, but frequently the use ofmodern and expensive instrumentation is indicated which maynot be accessible to everyone. Therefore, the use of these testmethods must be left to the discretion of
6、 each laboratory.1.4 The analytical procedures appear in the following order:SectionAluminum Oxide 15Available Lime Index 28Calcium and Magnesium Oxide:Alternative EDTA Titration Method 31Calcium Carbonate Equivalent 33Calcium Oxide:Gravimetric Method 16Volumetric Method 17Carbon Dioxide by Standard
7、 Method 22Combined Oxides of Iron and Aluminum 12Ferrous Iron Appendix X5Free Calcium Oxide Appendix X6Free Moisture in Hydrated Lime 21Free Moisture in Limestone 20Free Silica 29Insoluble Matter Including Silicon Dioxide:Standard Method 8Optional Perchloric Acid Method 9Insoluble Matter Other Than
8、Silicon Diox-ide11Loss on Ignition 19Magnesium Oxide 18Manganese:Bismuthate Method Appendix X4Periodate (Photometric) Method 27pH Determination of Alkaline Earth Solu-tions34Phosphorus:Titrimetric Method Appendix X3Molybdovanadate Method 26Silicon Dioxide 10Strontium Oxide Appendix X2Sulfur Trioxide
9、 23Total Carbon:Direct Combustion-Thermal Conductiv-ity Cell Method32Total Carbon and Sulfur:Combustion/Infrared Detection Method 35Total Iron:Standard Method, Potassium Dichro-mate Titration13Potassium Permanganate TitrationMethodAppendix X1Ortho-Phenanthroline, PhotometricMethod14Total Sulfur:Sodi
10、um Carbonate Fusion 24Combustion-Iodate Titration Method 25Unhydrated Oxides 301.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and dete
11、rmine the applica-bility of regulatory limitations prior to use. For specificprecautionary statements, see 9.3, 10.2.1, 18.4.3, 31.6.4.2,X2.3.1, and X5.4.1.1.2. Referenced Documents2.1 ASTM Standards:2C50 Practice for Sampling, Sample Preparation, Packaging,and Marking of Lime and Limestone Products
12、C51 Terminology Relating to Lime and Limestone (as usedby the Industry)C911 Specification for Quicklime, Hydrated Lime, and1These test methods are under the jurisdiction of ASTM Committee C07 onLime and are the direct responsibility of Subcommittee C07.05 on Chemical Tests.Current edition approved J
13、une 1, 2011. Published July 2011. Originally approvedin 1919. Last previous edition approved in 2006 as C2506. DOI: 10.1520/C0025-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume infor
14、mation, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Limestone for Selected Chemical and Industrial UsesD1193 Specification for Reagent WaterE29 Practice for Using Si
15、gnificant Digits in Test Data toDetermine Conformance with SpecificationsE50 Practices for Apparatus, Reagents, and Safety Consid-erations for Chemical Analysis of Metals, Ores, andRelated MaterialsE70 Test Method for pH of Aqueous Solutions With theGlass ElectrodeE173 Practice for Conducting Interl
16、aboratory Studies ofMethods for Chemical Analysis of Metals3E177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE200 Practice for Preparation, Standardization, and Storageof Standard and Reagent Solutions for Chemical AnalysisE691 Practice for Conducting an Interlaboratory Study
17、 toDetermine the Precision of a Test MethodE832 Specification for Laboratory Filter Papers3. Terminology3.1 DefinitionsUnless otherwise specified, for definitionsof terms used in these test methods refer to Terminology C51.4. Significance and Use4.1 These test methods provide accurate and reliable a
18、na-lytical procedures to determine the chemical constituents oflimestone, quicklime, and hydrated lime (See Note 1). Thepercentages of specific constituents which determine a materi-als quality or fitness for use are of significance dependingupon the purpose or end use of the material. Results obtai
19、nedmay be used in relation to specification requirements.4.2 Because quicklime and hydrated lime quickly absorbwater and carbon dioxide from the air, precision and bias areextremely dependent upon precautions taken during samplepreparation and analysis to minimize excessive exposure toambient condit
20、ions.NOTE 1These test methods can be applied to other calcareousmaterials if provisions are made to compensate for known interferences.5. General Apparatus and Materials and Reagents5.1 General Apparatus and Materials:5.1.1 BalanceThe balance shall be of an analytical typewith a capacity not to exce
21、ed 200 g. It may be of conventionaldesign or it may be a constant-load, direct-reading type. It shallbe capable of reproducing weighings within 0.0002 g with anaccuracy of 6 0.0002 g. Rapid weighing devices that may beprovided such as a chain, damper, or heavy riders shall notincrease the basic inac
22、curacy by more than 0.0001 g at anyreading and with any load within the rated capacity of thebalance.5.1.2 WeightsWeights used for analysis shall conform toClass S-1 requirements of the National Institute of Standardsand Technology as described in NIST Circular 547.4They shallbe checked at least onc
23、e a year or when questioned, andadjusted to within allowable tolerances for Class S-1 weights.All new sets of weights purchased shall have the weights of 1g and larger made of stainless steel or other corrosion-resistantalloy not requiring protective coating and shall meet thedensity requirements fo
24、r Class S.5.1.3 Glassware and Laboratory ContainersStandardvolumetric flasks, burets, pipets, dispensers, etc., shall becarefully selected precision grade or better and shall becalibrated, if necessary, to meet the requirements of eachoperation. Standard-type interchangeable ground glass or TFE-fluo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC252011STANDARDTESTMETHODSFORCHEMICALANALYSISOFLIMESTONEQUICKLIMEANDHYDRATEDLIME 石灰石 生石灰 熟石灰 化学分析

链接地址:http://www.mydoc123.com/p-466127.html