ASTM C1741-2011a Standard Test Method for Bleed Stability of Cementitious Post-Tensioning Tendon Grout《胶接后拉钢筋束水泥浆的漏铸稳定性的标准试验方法》.pdf
《ASTM C1741-2011a Standard Test Method for Bleed Stability of Cementitious Post-Tensioning Tendon Grout《胶接后拉钢筋束水泥浆的漏铸稳定性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1741-2011a Standard Test Method for Bleed Stability of Cementitious Post-Tensioning Tendon Grout《胶接后拉钢筋束水泥浆的漏铸稳定性的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation:C174111 Designation: C1741 11aStandard Test Method forBleed Stability of Cementitious Post-Tensioning TendonGrout1This standard is issued under the fixed designation C1741; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision
2、, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is designed to determine the bleed stability of freshly-mixed cementitious grout under
3、static pressure.1.2 UnitsThe values stated in SI units are to be regarded as standard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this sta
4、ndard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use. (WarningFresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin andtissue upon prolonged exposure.)22. Referenced Documents2.1 ASTM Standar
5、ds:3C125 Terminology Relating to Concrete and Concrete AggregatesC938 Practice for Proportioning Grout Mixtures for Preplaced-Aggregate Concrete3. Terminology3.1 DefinitionsFor definitions of terms used in this test method, refer to Terminology C125.3.2 Definitions of Terms Specific to This Standard
6、:3.2.1 bleed stability, nof cementitious grout, resistance to bleeding.3.2.2 bleeding, nof cementitious post-tensioning tendon grout, autogenous flow of mixing water within, or its emergencefrom, newly placed grout; caused by the settlement of the solid materials within the grout and the filtering a
7、ction of strands andwires when subjected to static pressure and capillary action.3.2.3 grout, nmixture of cementitious material and water, with or without aggregate and admixtures, proportioned to producea pourable consistency without segregation of the constituents.3.2.4 post-tensioning, adjreferri
8、ng to a method of prestressing in which prestressing steel is tensioned after the concrete hasgained sufficient strength.4. Significance and Use4.1 This test method is designed to evaluate the bleed stability of a freshly-mixed grout under static pressure. It can be usedin both the laboratory to qua
9、lify grout materials and in the field as a quality control test. When used to qualify grout materials,replicate tests may be specified. It is intended that the test pressure, acceptance criteria, and number of replicate tests be set forthin the contract documents if this test method is referenced. T
10、hese values will normally vary depending on the vertical rise of thepost-tensioning tendon.NOTE 1Appendix X1 includes a reference for an example of test pressures and bleeding limits.4.2 The procedure for this test was developed by Schokker et al.4based on previous work by Schupack.51This test metho
11、d is under the jurisdiction of ASTM Committee C09 on Concrete and Concrete Aggregates and is the direct responsibility of Subcommittee C09.41 onHydraulic Cement Grouts.Current edition approved May 1, 2011. Published June 2011. DOI: 10.1520/C1741-11Current edition approved Dec. 15, 2011. Published Ja
12、nuary 2012. Last previous edition approved in 2011 as C174111. DOI: 10.1520/C1741-11a2Section on Safety Precautions, Manual of Aggregate and Concrete Testing, Annual Book of ASTM Standards, Vol. 04.02.3For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Serv
13、ice at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.4Schokker, A. J., B.D. Koester, J.E. Breen, and M. E. Kreger, “Development of High Performance Grouts for Bonded Post- Tensioned Structures,” Research Report1
14、405-2, Center for Transportation Research, October 1999.5Schupack, M. “Admixture for Controlling Bleed in Cement Grout Used in Post-Tensioning,” Precast/Prestressed Concrete Institute Journal, Nov.-Dec. 1974 , pp. 1-10.1This document is not an ASTM standard and is intended only to provide the user o
15、f an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as pu
16、blished by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5. Apparatus5.1 The apparatus consists of a commercially available pressure filtration funnel, stand, pressure supply with gauge
17、, pressureregulator, valve, drip wick, and bleed water collection container as shown in Fig. 1 and Fig. 2.5.1.1 Filtration FunnelA 47-mm diameter stainless steel pressure filtration funnel with a nominal capacity of 200 mL asshown in Fig. 2. The filtration funnel shall have removable threaded caps a
18、t both ends with a stem for connection of the gas supplyand a 7.0 6 0.5 mm inside diameter stem 90 6 1 mm long for escape of water. The base of the vessel shall contain a 35 6 1mmdiameter stainless steel 45 m (No. 325) screen that supports a 47 mm diameter Type A/E borosilicate glass filter (1-m por
19、e size)as shown in Fig. 2. The screen shall be inserted with the woven side against the glass filter, and the funnel gasket shall be placedabove the glass filter as shown in Fig. 2. The glass filter shall cover the screen across the inside diameter of the bottom cap andbe located under the gasket wh
20、en under pressure. Secure the bottom cap before filling the filtration funnel with grout. The funnelis placed in the stand after it is filled.5.1.2 StandThe filtration funnel shall be attached to a stand capable of holding the funnel in the vertical position withadequate space for the bleed water co
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC17412011ASTANDARDTESTMETHODFORBLEEDSTABILITYOFCEMENTITIOUSPOSTTENSIONINGTENDONGROUT 胶接后拉 钢筋 水泥浆

链接地址:http://www.mydoc123.com/p-465723.html