1、Designation: C 1565 04Standard Test Method forDetermination of Pack-Set Index of Portland Cement1This standard is issued under the fixed designation C 1565; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、 A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the pack-set index, which provides an indication of the mechanical forceneeded to over
3、come the consolidation of portland cement.1.2 The pack-set index number provides a numerical valueuseful for manufacturers who desire to measure and control theeffect that vibration-induced consolidation has upon the manu-factured cement.1.3 The values stated in SI units are to be regarded as thesta
4、ndard. Values stated in Inch-Pound units are for informa-tional purposes only and are enclosed in parentheses. Valuesstated in SI units shall be obtained by measurement in SI unitsor by appropriate conversion, using the rules of Conversionand rounding given in Standard IEEE/ASTM SI 10, of mea-sureme
5、nts made in other units.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prio
6、r to use. (WARNINGFresh hydraulic-cementitious mixtures are caustic and maycause chemical burns to skin and tissue upon prolongedexposure.)22. Referenced Documents2.1 ASTM Standards:3C 1005 Specification for Reference Masses and Devices forDetermining Mass and Volume for Use in the PhysicalTesting o
7、f Hydraulic CementsIEEE/ASTM SI 10 International System of Units (SI) TheModernized Metric System3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 maximum voltage, nas pertaining to this methodonly, the energy in volts applied to consolidate the sample,which results in the maxim
8、um pack-set index for a particularcement and the apparatus used for the measurement.3.1.2 pack set, na condition of hydraulic cement, exhib-ited in varying degrees, following silo storage or transport inbulk railcars or trucks, that causes the cement to resist flowinguntil considerable mechanical ef
9、fort has been applied.3.1.3 pack-set index, nthe numerical indication of thedegree of pack set a particular cement exhibits when subjectedto the procedures of this test method.4. Summary of Test Method4.1 Portland cement is placed into a flask and then consoli-dated on a vibrating table by a vibrati
10、on force controlled bytime and energy (volts). The consolidated bed is measured forrelative strength by turning the flask to a horizontal positionand rotating in 180 increments until the bed collapses from thebottom of the flask. The number of half turns is a relativeindication of the force required
11、 to overcome the consolidationand is designated the pack-set index, or P.S.I.5. Significance and Use5.1 This method is intended to help manufacturers deter-mine the relative pack-set tendency of their cement(s). The testestablishes a pack-set index which, when properly correlatedwith field performan
12、ce, is useful in predicting or preventingfield unloading difficulties.5.2 The test is an aid to routine control during cementproduction and is not suitable for specification purposes.5.3 In general, field performance of cement flowability issatisfactory when the pack-set index as determined on fresh
13、lyground cement averages 0 to 15 and is unsatisfactory when theindex exceeds 25. Any prediction of field performance ofcement flowability measuring 16 to 25 is tenable. These aregeneral ranges and the field performance of individual cementsmay not necessarily fall within these ranges. Additional con
14、-ditions, after the cement has left the control of the manufac-turing facility, can affect the apparent pack set index as well.5.4 Any attempt to apply the critical range of pack-set indexnumbers based on freshly ground cement to job cement withoutspecial treatment of the sample would be problematic
15、. The testis a “GO-NO GO” type of test and should not be used forspecification purposes.1This test method is under the jurisdiction of ASTM Committee C01 on Cementand is the direct responsibility of Subcommittee C01.20 on Additions.Current edition approved August 1, 2004. Published September 2004. O
16、riginallyapproved in 2003. Last previous edition approved in 2003 as C 1565 03.2Section on Safety, Manual of Cement Testing, Annual Book of ASTMStandards, Vol 04.01.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Bo
17、ok of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.5 The pack-set index of field cement can be evaluated interms of the pack-set i
18、ndex ranges of that cement as determinedwhen freshly-ground. This comparison can aid the manufac-turer in producing cement that offers the best field performancefor pack-set properties.5.6 Silo storage of cement may result in a greater amount ofconsolidation than this method is designed to induce, a
19、nd theresulting forces required to overcome that consolidation are notmeasured by this test method.5.7 Pack set is not to be confused with “warehouse set”which results from surface hydration of the cement fromadsorbed moisture.6. Interferences6.1 Results obtained from the pack-set test are dependent
20、 onsample exposure (See Note 1).NOTE 1Fresh cement has a greater pack-set tendency. Cement storedin silos for only a day or two will test similar to fresh cement. Cementstored in full silos, where aeration is negligible, may develop lowerpack-set indices upon further aging, Even samples in sealed co
21、ntainersmay vary.6.2 Pack-set index determination can be affected by sampletemperature (See Note 2).NOTE 2Cement with a temperature noticeably hotter than roomtemperature may produce a different pack-set index number than that samecement cooled to room temperature. Cooling of hot cement samples must
22、be accomplished with minimum aeration to avoid moisture and CO2adsorption.6.3 The testing room humidity can significantly influencethe determined pack-set index.6.4 Keep the apparatus level during the testing procedure.6.5 The vibration energy transferred to the sample is af-fected by the support gi
23、ven the apparatus (See Note 3). Thedetermination of pack-set index for unknown samples shall beaccomplished on the same physical support that the maximumvoltage for the test was determined on.NOTE 3Apparatus which is not setting firmly on the counter or tablemay not deliver repeatable results.6.6 Vi
24、bration energy delivered by the table is related to theproper handling and adjustment of the table. See Section 7 fordetails.6.7 Vibration energy delivered by the table is related to thefrequency of the source voltage. This variation, if present, willresult in a poor repeatability and require more f
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC15652004STANDARDTESTMETHODFORDETERMINATIONOFPACKSETINDEXOFPORTLANDCEMENT 硅酸盐水泥 PACKSET 指数 测定 标准

链接地址:http://www.mydoc123.com/p-465144.html