1、Designation: C150/C150M 161Standard Specification forPortland Cement1This standard is issued under the fixed designation C150/C150M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, the year of last revision. A number in parentheses
2、 indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTERevised editorially to remove an erroneous reference in 9.1.7 in July 2016.1. Scope*1.1 This specification covers ten types of portland cement,as follows (see Note
3、 2):1.1.1 Type IFor use when the special properties specifiedfor any other type are not required.1.1.2 Type IAAir-entraining cement for the same uses asType I, where air-entrainment is desired.1.1.3 Type IIFor general use, more especially when mod-erate sulfate resistance is desired.1.1.4 Type IIAAi
4、r-entraining cement for the same uses asType II, where air-entrainment is desired.1.1.5 Type II(MH)For general use, more especially whenmoderate heat of hydration and moderate sulfate resistance aredesired.1.1.6 Type II(MH)AAir-entraining cement for the sameuses as Type II(MH), where air-entrainment
5、 is desired.1.1.7 Type IIIFor use when high early strength is desired.1.1.8 Type IIIAAir-entraining cement for the same use asType III, where air-entrainment is desired.1.1.9 Type IVFor use when a low heat of hydration isdesired.1.1.10 Type VFor use when high sulfate resistance isdesired.NOTE 1Some
6、cements are designated with a combined typeclassification, such as Type I/II, indicating that the cement meets therequirements of the indicated types and is being offered as suitable for usewhen either type is desired.NOTE 2Cement conforming to the requirements for all types are notcarried in stock
7、in some areas. In advance of specifying the use of cementother than Type I, determine whether the proposed type of cement is, orcan be made, available.1.2 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exa
8、ct equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard. Values in SI units or inch-pound units shallbe obtained by measurement in SI units or inch-pound unitsor by appropriate conversion, usi
9、ng the Rules for Conversionand Rounding given in IEEE/ASTM SI 10, of measurementsmade in other units or SI units. Values are stated in only SIunits when inch-pound units are not used in practice.1.3 The text of this standard references notes and footnoteswhich provide explanatory material. These not
10、es and footnotes(excluding those in tables and figures) shall not be consideredas requirements of the standard.2. Referenced Documents2.1 ASTM Standards:2C33 Specification for Concrete AggregatesC51 Terminology Relating to Lime and Limestone (as usedby the Industry)C109/C109M Test Method for Compres
11、sive Strength ofHydraulic Cement Mortars (Using 2-in. or 50-mm CubeSpecimens)C114 Test Methods for Chemical Analysis of HydraulicCementC115 Test Method for Fineness of Portland Cement by theTurbidimeterC151 Test Method for Autoclave Expansion of HydraulicCementC183 Practice for Sampling and the Amou
12、nt of Testing ofHydraulic CementC185 Test Method for Air Content of Hydraulic CementMortarC186 Test Method for Heat of Hydration of HydraulicCementC191 Test Methods for Time of Setting of Hydraulic Cementby Vicat NeedleC204 Test Methods for Fineness of Hydraulic Cement byAir-Permeability ApparatusC2
13、19 Terminology Relating to Hydraulic CementC226 Specification for Air-Entraining Additions for Use inthe Manufacture of Air-Entraining Hydraulic Cement1This specification is under the jurisdiction of ASTM Committee C01 onCement and is the direct responsibility of Subcommittee C01.10 on HydraulicCeme
14、nts for General Concrete Construction.Current edition approved March 15, 2016. Published April 2016. Originallyapproved in 1940. Last previous edition approved in 2015 as C150/C150M 15.DOI: 10.1520/C0150_C0150M-16E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact AST
15、M Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshoho
16、cken, PA 19428-2959. United States1C266 Test Method for Time of Setting of Hydraulic-CementPaste by Gillmore NeedlesC451 Test Method for Early Stiffening of Hydraulic Cement(Paste Method)C452 Test Method for Potential Expansion of Portland-Cement Mortars Exposed to SulfateC465 Specification for Proc
17、essing Additions for Use in theManufacture of Hydraulic CementsC563 Test Method for Approximation of Optimum SO3inHydraulic Cement Using Compressive StrengthC1038 Test Method for Expansion of Hydraulic CementMortar Bars Stored in WaterC1702 Test Method for Measurement of Heat of Hydrationof Hydrauli
18、c Cementitious Materials Using IsothermalConduction CalorimetryE29 Practice for Using Significant Digits in Test Data toDetermine Conformance with SpecificationsIEEE/ASTM SI 10 American National Standard for Use ofthe International System of Units (SI): The Modern MetricSystem3. Terminology3.1 Defin
19、itionsSee Terminology C219.4. Ordering Information4.1 Orders for material under this specification shall includethe following:4.1.1 This specification number and date,4.1.2 Type or types allowable. If no type is specified,Type I shall be supplied,4.1.3 Any optional chemical requirements from Table 2
20、,ifdesired, and4.1.4 Any optional physical requirements from Table 4,ifdesired.5. Ingredients5.1 The cement covered by this specification shall containno ingredients except as follows:5.1.1 Portland cement clinker.5.1.2 Water or calcium sulfate, or both. The amounts shallbe such that the limits show
21、n in Table 1 for sulfur trioxide andloss-on-ignition are not exceeded.5.1.3 Limestone. The amount shall not be more than 5.0 %by mass such that the chemical and physical requirements ofthis standard are met (see Note 3). The limestone, defined inTerminology C51, shall be naturally occurring and cons
22、ist of atleast 70 % by mass of one or more of the mineral forms ofcalcium carbonate. If limestone is used, the manufacturer shallreport the amount used, expressed as a percentage of cementmass, as determined using Annex A2, along with the oxidecomposition of the limestone.NOTE 3The standard permits
23、up to 5 % by mass of the final cementproduct to be naturally occurring, finely ground limestone, but does notrequire that limestone be added to the cement. Cement without groundlimestone can be specified in the contract or order.5.1.4 Inorganic processing additions. The amount shall benot more than
24、5.0 % by mass of cement. Not more than oneinorganic processing addition shall be used at a time. Foramounts greater than 1.0 %, they shall have been shown tomeet the requirements of Specification C465 for the inorganicTABLE 1 Standard Composition RequirementsCement TypeAApplicableTestMethodI andIAII
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC150C150M2016E1STANDARDSPECIFICATIONFORPORTLANDCEMENT 硅酸盐水泥 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-464887.html