ASTM C1497-2016 Standard Specification for Cellulosic Fiber Stabilized Thermal Insulation《纤维素纤维稳定热绝缘材料的标准规格》.pdf
《ASTM C1497-2016 Standard Specification for Cellulosic Fiber Stabilized Thermal Insulation《纤维素纤维稳定热绝缘材料的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1497-2016 Standard Specification for Cellulosic Fiber Stabilized Thermal Insulation《纤维素纤维稳定热绝缘材料的标准规格》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1497 16Standard Specification forCellulosic Fiber Stabilized Thermal Insulation1This standard is issued under the fixed designation C1497; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A n
2、umber in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers the composition and physicalproperties of spray-applied cellulosic fiber stabilized thermalinsulation applied
3、to open or closed ceiling spaces, regardlessof slope, where temperatures range from 49 to 194F (45 to90C).1.2 Stabilized cellulosic fiber thermal insulation is producedby the addition of adhesive(s) to loose-fill cellulosic fiberinsulation. The adhesive(s) are either added to the insulation attime o
4、f manufacture and, if necessary, activated by the additionof water when installed or the adhesive(s) are otherwise addedto the insulation at the time of installation.1.3 This is a material specification that is not intended todeal with methods of application that are supplied by themanufacturer.1.4
5、The values stated in inch-pound units are to be regardedas standard. The SI units given in parentheses are for informa-tion only.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish
6、 appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C167 Test Methods for Thickness and Density of Blanket orBatt Thermal InsulationsC168 Terminology Relating to Thermal InsulationC177 Test Metho
7、d for Steady-State Heat Flux Measure-ments and Thermal Transmission Properties by Means ofthe Guarded-Hot-Plate ApparatusC739 Specification for Cellulosic Fiber Loose-Fill ThermalInsulationC1149 Specification for Self-Supported Spray Applied Cel-lulosic Thermal InsulationC1304 Test Method for Assess
8、ing the Odor Emission ofThermal Insulation MaterialsC1338 Test Method for Determining Fungi Resistance ofInsulation Materials and FacingsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE970 Test Method for Critical Radiant Flux of ExposedAtticFloor Ins
9、ulation Using a Radiant Heat Energy Source3. Terminology3.1 DefinitionsFor definitions of terms used in thisspecification, see Terminology C168.3.2 Definitions of Terms Specific to This Standard:3.2.1 shrinkagedecrease in thickness that occurs from thetime of installation until the insulation is dry
10、 (see 7.2.5).3.2.2 stabilized cellulosea cellulosic insulation producttreated to resist, after drying, further settling of no more than5%.4. Materials and Manufacture4.1 The basic material shall be recycled cellulosic fibermade from selected paper or paperboard stock. Additives areintroduced to affe
11、ct different performance characteristics, in-cluding those related to fire performance, processing, andhandling. An adhesive is added to the insulation product toresist long-term settling of the insulation after installation andcuring.4.2 The materials are processed into a form suitable forinstallat
12、ion by a pneumatic method.4.3 The adhesive is added to the product either at the time ofmanufacture or at the time of installation by means of a liquidspray.5. Physical and Chemical Properties5.1 DensityThe density of conditioned stabilized insula-tion in lb/ft3(kg/m3) shall be determined in accorda
13、nce withSection 7.5.2 CorrosivenessThe loose-fill insulation material shallbe tested for corrosiveness in accordance with Section 8. The1This specification is under the jurisdiction of ASTM Committee C16 onThermal Insulation and is the direct responsibility of Subcommittee C16.23 onBlanket and Loose
14、 Fill Insulation.Current edition approved Oct. 1, 2016. Published October 2016. Originallyapproved in 2001. Last previous edition approved in 2012 as C1497 12. DOI:10.1520/C1497-16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.or
15、g. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1composition of the insulation material shall be such that aftertes
16、ting, no perforation of the 0.003 in. (0.076 mm) metalspecimens shall be evident when the specimens are observedover a 40-W appliance light bulb. Notches extending into thecoupon 0.1 in. (3 mm) or less from any edge shall be ignored.5.3 Critical Radiant FluxWhen tested in accordance withSection 9, t
17、he critical radiant flux shall be equal to or greaterthan 0.11 Btu/ft2s (0.12W/cm2).All values shall be reported totwo significant digits.5.4 Fungi ResistanceThe loose-fill insulation materialshall be tested and pass fungi resistance as specified in Section10. All three test specimens shall exhibit
18、growth less than orequal to the comparative material in order to pass.5.5 Water Vapor SorptionMoisture gain in the insulationshall be no more than 15 % by weight when tested inaccordance with Section 11.5.6 Odor EmissionAny sample producing a detectableodor that is classified as objectionable and st
19、rong or strong bymore than two panel members shall be considered to havefailed the test when tested in accordance with Section 12.5.7 Smoldering CombustionWhen tested in accordancewith the smoldering combustion test method in Section 13, theinsulation shall show no evidence of flaming and a weight l
20、ossof no greater than 15 % of the specimen weight.5.8 Thermal ResistanceThe standard thermal resistancevalues recommended for application shall be expressed inFhft2/Btu (Km2/W). The R-value shall be measured inaccordance with Section 14. During random sampling, anaverage measured R for four specimen
21、s that is 95 % of thelabeled value shall be acceptable provided no measurement isless than 90 % of the labeled value.35.9 Permanency of Flame Retardant TreatmentIt is im-portant to ensure that the fire test response characteristics of thecellulosic fiber insulation, expressed as the critical radiant
22、 fluxin accordance with 5.3 or as the smoldering performance inaccordance with 5.7, not be degraded over time. The rationalefor the concern is that the additives used for improving the firetest response characteristics of cellulosic fiber insulation arephysically added to the cellulose and are not c
23、hemically boundto the cellulose. Studies have been made in the past indicatingthat cellulose insulation treated with boric acid (1),4borates(2), and ammonium sulfate (3) retains its fire test responsecharacteristics for years, based on cellulose insulation that hadbeen installed for periods of up to
24、 14 years (4,5). No data hasbeen presented to the committee to update or revise thisinformation and no permanency test method has been devel-oped to date.5.10 ShrinkageThe shrinkage (S1) determined in accor-dance with Section 7.5.11 SettlingThe settling (S2) determined in accordancewith Section 7 sh
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC14972016STANDARDSPECIFICATIONFORCELLULOSICFIBERSTABILIZEDTHERMALINSULATION 纤维素 纤维 稳定 绝缘材料 标准 规格

链接地址:http://www.mydoc123.com/p-464868.html