ASTM C1346-2008(2014) Standard Practice for Dissolution of UF6 from P-10 Tubes《P-10管中UF 6溶解的标准操作规程》.pdf
《ASTM C1346-2008(2014) Standard Practice for Dissolution of UF6 from P-10 Tubes《P-10管中UF 6溶解的标准操作规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1346-2008(2014) Standard Practice for Dissolution of UF6 from P-10 Tubes《P-10管中UF 6溶解的标准操作规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1346 08 (Reapproved 2014)Standard Practice forDissolution of UF6from P-10 Tubes1,2This standard is issued under the fixed designation C1346; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A
2、 number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the dissolution of UF6from a P-10tube to provide solutions for analysis.1.2 The values stated in SI units are to
3、be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and
4、determine the applica-bility of regulatory limitations prior to use. For specificsafeguard and safety precaution statements, see Section 8.2. Referenced Documents2.1 ASTM Standards:3C761 Test Methods for Chemical, Mass Spectrometric,Spectrochemical, Nuclear, and RadiochemicalAnalysis ofUranium Hexaf
5、luorideC787 Specification for Uranium Hexafluoride for Enrich-mentC996 Specification for Uranium Hexafluoride Enriched toLess Than 5 %235UD1193 Specification for Reagent Water3. Summary of Practice3.1 UF6samples intended for analysis are packaged in P-10tubes to prevent sublimation and reaction with
6、 moisture in theair. The P-10 tube assembly (Fig. 1) consists of a Polychloro-trifluoroethylene (PCTFE) tube containing the UF6, a PCTFEgasket to cover the tubes opening, and a nut and plug (Monelor SS) to seal the gasket to the tube.3.2 The UF6tube is weighed, cooled in liquid nitrogen, andquickly
7、opened and immersed in water for dissolution. Thepieces of the tubes assembly are removed from the resultingsolution, rinsed, dried, reassembled, and weighed. The solutionis dried for gravimetric conversion to U3O8, or diluted to anappropriate concentration for dispensing into aliquots forsubsequent
8、 analysis.4. Significance and Use4.1 Uranium hexafluoride is a basic material used to preparenuclear reactor fuel. To be suitable for this purpose the materialmust meet criteria for uranium content, isotopic compositionand metallic impurities in Specification C787 and C996. Thispractice results in t
9、he complete dissolution of the sample foruranium and impurities analysis, and determination of isotopicdistribution by mass spectrometry as described in, for example,Test Methods C761.5. Apparatus5.1 Steam bath, in a hood, if optional step 9.2.13 is used.5.2 Vacuum oven, if option 2 of 9.2.14 is use
10、d. The ovenshould be adjustable to 80C at an absolute pressure of 3 103Pa.5.3 Dewar flask, wide-mouth.5.4 Vise, small lab-bench model or similar type of holder.5.5 Wrench,1516 in.5.6 Plastic clamping forceps, 12 to 13 cm long, with aclaw-like bent tip, to securely hold the cylindrical PCTFE tube.NOT
11、E 1These forceps are not commercially available. Bend the endsof a straight-tip forceps by heating over a moderate flame, shaping, andmaintaining the shape until cool.5.7 TFE-fluorocarbon-coated spatula, 0.5- to 1-cm wide atits flat end, optional.5.8 Platinum or PCTFE rod, optional.5.9 Platinum dish
12、es or plastic beakers with compatible HFresistance (typically PolyEthylene; PE), large enough to con-tain a completely submerged P-10 tube.1This practice is under the jurisdiction of ASTM Committee C26 on NuclearFuel Cycle and is the direct responsibility of Subcommittee C26.05 on Methods ofTest.Cur
13、rent edition approved Jan. 1, 2014. Published February 2014. Originallyapproved in 1996. Last previous edition approved in 2008 as C1346 08. DOI:10.1520/C1346-08R14.2Polychlorotrifluoroethylene P-10 tubes are widely accepted by the industry forsubsample collection and subsequent UF6quality analyses
14、or dispatch to thecustomer. The procedure for subsample collection and dissolution can also be usedfor other types of subsample tubes, for example, P-20, P-80 or P-100 , in that casethe amount of water has to be adjusted to ensure complete hydrolisation of UF6andavoid excessive heat evolution.3For r
15、eferenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, W
16、est Conshohocken, PA 19428-2959. United States15.10 Copper wires, optional. The wires should be flexibleand looped at one end to loosely fit around the PCTFE tubewithout allowing the flare nut to pass through.5.11 Desiccator, optional.5.12 Balance, 100-g capacity, readable to at least 0.1 mg,prefera
17、bly 0.01 mg.NOTE 2Use of a balance with lower sensitivity will negatively impacton sampling error.6. Interferences6.1 The weight of the PCTFE tube is affected by atmo-spheric humidity. Keep the P-10 tube assembly in a desiccatorbetween weighings until constant weight is attained.6.2 The capacity of
18、the UF6tube (a maximum of approxi-mately 13.0 g UF6) limits the number and size of the aliquotsthat can be obtained from each tube. See analytical proceduresfor their requirements.7. Reagents7.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is in
19、tended thatall reagents conform to the specifications of the Committee onAnalytical Reagents of the American Chemical Society wheresuch specifications are available.4Other grades of reagentsmay be used, provided it is first ascertained that the reagent isof sufficiently high purity to permit its use
20、 without lesseningthe accuracy of the determination.7.2 Liquid nitrogen.7.3 Deionized distilled water in accordance with Specifica-tion D1193, approximately 50100 cm3per sample.7.4 Ethanol or other suitable, volatile organic solvent.8. Hazards8.1 Since UF6materials are radioactive, toxic, and highly
21、reactive, especially with reducing substances and moisture,adequate laboratory facilities and fume hoods along with safetechniques must be used in handling samples containing thesematerials. A detailed discussion of all necessary precautions isbeyond the scope of this practice. However, personnel wh
22、ohandle radioactive materials should be familiar with the safehandling practices of the facility.8.2 Follow all safety procedures for handling uranium andUF6provided by the facility. Review the Material Safety DataSheet (MSDS) for UF6prior to performing the procedure.8.3 Perform dissolutions in a la
23、boratory hood. Hoods shouldbe regularly inspected for proper air flow.8.4 Gaseous UF6, when released to the atmosphere, reactswith moisture to form HF gas and UO2F2particulate (a whiteamorphous solid that settles on all surfaces). Release of UF6tothe atmosphere is readily visible as a white cloud. T
24、hecorrosive nature of HF and UF6can cause skin burns and lungimpairment. Medical evaluation is mandatory for all situationswhere there may have been inhalation or contact with HF orUF6. Water soluble UO2F2, when inhaled or ingested in largequantities, is toxic to the kidneys.8.5 Use gloves designed
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC134620082014STANDARDPRACTICEFORDISSOLUTIONOFUF6FROMP10TUBESP10 UF6 溶解 标准 操作规程 PDF

链接地址:http://www.mydoc123.com/p-464305.html