ASTM C1307-2002 Standard Test Method for Plutonium Assay by Plutonium (III) Diode Array Spectrophotometry《用(III)钚数组分光光度法鉴定钚的标准测试方法》.pdf
《ASTM C1307-2002 Standard Test Method for Plutonium Assay by Plutonium (III) Diode Array Spectrophotometry《用(III)钚数组分光光度法鉴定钚的标准测试方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1307-2002 Standard Test Method for Plutonium Assay by Plutonium (III) Diode Array Spectrophotometry《用(III)钚数组分光光度法鉴定钚的标准测试方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1307 02Standard Test Method forPlutonium Assay by Plutonium (III) Diode ArraySpectrophotometry1This standard is issued under the fixed designation C 1307; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of l
2、ast revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes the determination of totalplutonium as plutonium(III) in nitrate and chloride solutions.The
3、 technique is applicable to solutions of plutonium dioxidepowders and pellets (Test Methods C 697), nuclear grademixed oxides (Test Methods C 698), plutonium metal (TestMethods C 758), and plutonium nitrate solutions (Test Meth-ods C 759). Solid samples are dissolved using the appropriatedissolution
4、 techniques described in Practice C 1168. The use ofthis technique for other plutonium-bearing materials has beenreported (1-5), but final determination of applicability must bemade by the user. The applicable concentration range forplutonium sample solutions is 10200 g Pu/L.21.2 This standard does
5、not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standa
6、rds:C 697 Test Methods for Chemical, Mass Spectrometric, andSpectrochemical Analysis of Nuclear-Grade PlutoniumDioxide Powders and Pellets3C 698 Test Methods for Chemical, Mass Spectrometric, andSpectrochemical Analysis of Nuclear-Grade Mixed Oxides(U, Pu)O2)3C 757 Specification for Nuclear-Grade Pl
7、utonium DioxidePowder, Sinterable3C 758 Test Methods for Chemical, Mass Spectrometric,Spectrochemical, Nuclear, and Radiochemical Analysis ofNuclear-Grade Plutonium Metal3C 759 Test Methods for Chemical, Mass Spectrometric,Spectrochemical, Nuclear, and Radiochemical Analysis ofNuclear-Grade Plutoniu
8、m Nitrate Solutions3C 833 Specification for Sintered (Uranium-Plutonium) Di-oxide Pellets3C 1168 Practice for Preparation and Dissolution of Pluto-nium Materials for Analysis33. Summary of Method3.1 In a diode array spectrophotometric measurement, as ina conventional spectrophotometric measurement,
9、the substancebeing determined absorbs light at frequencies characteristic ofthat substance. The amount of light absorbed at each wave-length is directly proportional to the concentration of thespecies of interest. The absorption is a function of the oxidationstate and the complexation obtained in th
10、e solution matrixselected for measurement. Beers Law permits quantifying thespecies of interest relative to a traceable standard when bothsolutions are measured under the same conditions. The array ofphotosensitive diodes permits the (virtually) simultaneouscollection of spectral information over th
11、e entire range of theinstrument, for example, 190820 nm (or any selected portionof the range). An entire absorption spectrum can be obtained in0.1 s; however, optimum precision is obtained from multiplespectra collected over a 4-s period.3.2 Reduction to plutonium(III) is accomplished by theaddition
12、 of a measured quantity of reductant solution to thesample aliquant.3.2.1 For nitrate solutions, ferrous sulfamate is the recom-mended reductant. Aliquants (1 mL or less) of the samplesolution are diluted with 10 mL of a ferrous reductant/matrixsolution to 1 g Pu/L, and measured.3.2.2 For chloride s
13、olutions, ascorbic acid is the recom-mended reductant. Aliquants of the sample solution, eachcontaining 50100 mg of plutonium, are diluted with 2 mL ofzirconium solution to complex fluoride ions, 2 mL ascorbicacid reductant solution, and 1.0 M HCl to a total volume of 25mL, yielding 24 g Pu/L soluti
14、ons for measurement.3.3 Plutonium concentration is determined from light ab-sorption measurements taken on the sample solution in theblue-green region from 516 to 640 nm where a broad doubletband is observed. Spectral quantifying software capable offitting the sample spectrum with spectral informati
15、on fromstandard solutions is used to calculate the plutonium concen-tration. Both commercially available (6) and custom-designed1This test method is under the jurisdiction of ASTM Committee C-26 on NuclearFuel Cycle and is the direct responsibility of Subcommittee C26.05 on Methods ofTest.Current ed
16、ition approved Jan. 10, 2002. Published May 2002. Originallypublished as C130795. Last previous edition C130795.2For solid samples, select the sample size and dissolved solution weight to yieldsample solutions in the 1030 g Pu/L range. With special preparation and spectralanalysis techniques, the me
17、thod has been applied to nitrate solutions in the 0.110g Pu/L range.3Annual Book of ASTM Standards, Vol 12.01.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.(7-12) spectral fitting software have been developed whichmay be used for p
18、lutonium measurements. The users of thisprocedure are responsible for selecting or customizing, or both,the spectral fitting (and instrument control) software that bestmeets their individual measurement methodology and needs.Software selection will dictate many of the procedural specificsnot include
19、d in this procedure. This procedure is intended toaddress key measurement requirements and to allow usersdiscretion in establishing appropriate procedural details andtechnique variations. The software package selected shouldinclude a feature that indicates the quality of spectral fit,thereby providi
20、ng information on the measurement reliabilityand the presence of interferences that absorb light or otherwisealter the plutonium(III) spectrum without requiring supplemen-tal measurements.4. Significance and Use4.1 This test method is designed to determine whether agiven material meets the purchaser
21、s specification for pluto-nium content.5. Interferences5.1 Materials meeting the applicable material specificationsof the ASTM standard for which this procedure was developed,when dissolved and diluted without introduction of interferingcontaminants as described in Practice C 1168, will contain noin
22、terfering elements or species.NOTE 1Fluoride, if present, would interfere if the zirconium, rou-tinely added to the sample solution aliquant for the chloride matrix, wereomitted from the procedure. Zirconium may be added to the nitrate matrix.Ferrous-Reductant Solution to handle fluorides if present
23、. Zirconium,when used, should be added to all samples, blanks, and standards to obtaina consistent matrix. Refer to Specifications C 833 and C 757.5.2 Interferences are caused by: 1) materials that absorblight in the region of the plutonium absorption, 2) undissolvedsolids that cause light scatterin
24、g, 3) strong oxidizing orcomplexing agents that prevent complete reduction of theplutonium to the plutonium(III) oxidation state, and 4) anionsthat shift the spectrum.5.2.1 Absorption of light in the region of interest by anotherspecies is a potential interference. Identification of potentiallyinter
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC13072002STANDARDTESTMETHODFORPLUTONIUMASSAYBYPLUTONIUMIIIDIODEARRAYSPECTROPHOTOMETRY III 数组 分光光度法

链接地址:http://www.mydoc123.com/p-464168.html