《ASTM C1258-2008 Standard Test Method for Elevated Temperature and Humidity Resistance of Vapor Retarders for Insulation《隔热用蒸汽缓凝剂耐高温和耐湿度性能标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1258-2008 Standard Test Method for Elevated Temperature and Humidity Resistance of Vapor Retarders for Insulation《隔热用蒸汽缓凝剂耐高温和耐湿度性能标准试验方法》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1258 08Standard Test Method forElevated Temperature and Humidity Resistance of VaporRetarders for Insulation1This standard is issued under the fixed designation C 1258; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、 the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the agingresistance of flexible low permeance vapor retarder
3、s forthermal insulation as classified in Specification C 1136. Watervapor permeance measurement and visual inspection afterexposure at elevated temperature and humidity are used toassess vapor retarder response.1.2 Typical vapor retarders applicable to this test methodthat are intended for indoor us
4、e include foil-scrim-kraft lami-nates, metallized polyester-scrim-kraft laminates, treated fab-rics, treated papers, films, foils, or combinations of thesematerials that may comprise a vapor retarder material. This testmethod is not intended for assessment of the liquid-appliedcoatings, sealants, or
5、 mastics commonly used with insulationproducts.1.3 The values stated in inch-pound units are to be regardedas standard. The SI units given in parentheses are for informa-tion purposes only.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is
6、 theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 168 Terminology Relating to Thermal InsulationC 1136 Specification for Flexible,
7、Low Permeance VaporRetarders for Thermal InsulationE 96/E 96M Test Methods for Water Vapor Transmission ofMaterials3. Terminology3.1 Terminology C 168 shall be considered as applying tothe terms used in this specification.4. Summary of Test Method4.1 The vapor retarders are subjected to accelerated
8、agingvia elevated temperature and humidity at 120F (49C) and95 % relative humidity for a period of 28 days, then visuallyinspected for corrosion (if applicable), delamination, or otherdegradation. Water vapor permeance in accordance with TestMethods E 96/E 96M is measured after humid aging.5. Signif
9、icance and Use5.1 On sub-ambient temperature systems, humid ambientconditions cause a vapor driving force toward the insulationwhich, if not retarded, is detrimental to the insulations thermalresistance. Therefore a vapor retarder should resist degrada-tion. Degradation in this test method is induce
10、d by elevatedtemperature and humidity conditions.6. Apparatus6.1 Environmental Chamber, capable of maintaining 120 62F (49 6 1C) and 95 6 2 % relative humidity, using distilledor deionized water as the humidity source. The chamber shallbe of the air-circulating variety.6.2 Lighted Box in a Darkened
11、RoomA lighted box is anenclosure having five opaque sides with one transparent glassor plastic viewing side. The box is illuminated using anincandescent lightbulb. The viewing area shall be slightlysmaller than the vapor retarder specimen so that holes ordegradation caused by aging are readily visib
12、le.6.3 Cotton Gloves.6.4 Cardboard Overhead Transparency Frames or Equiva-lent.6.5 Stainless Steel Staples.6.6 Glass or Stainless Steel Rods.7. Test Specimens7.1 From each sample cut four specimens that are largeenough to acquire water vapor permeance test specimens afterexposure. The specimens shal
13、l be cut in a manner which bestcharacterizes the roll width. Material exhibiting extraneousdamage from mishandling in shipment or during samplepreparation shall be avoided. A fifth specimen shall be cut andretained as a control. An 1134 in. (298 mm) by 1034 in. (273mm) specimen size is recommended s
14、ince this is the size of atypical overhead transparency frame, which is useful to support1This test method is under the jurisdiction ofASTM Committee C16 on ThermalInsulation and is the direct responsibility of Subcommittee C16.33 on InsulationFinishes and Moisture.Current edition approved Aug. 1, 2
15、008. Published August 2008. Originallyapproved in 1994. Last previous edition approved in 2000 as C 125894(2000).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC12582008STANDARDTESTMETHODFORELEVATEDTEMPERATUREANDHUMIDITYRESISTANCEOFVAPORRETARDERSFORINSULATION

链接地址:http://www.mydoc123.com/p-463953.html