1、Designation: C 1086 96 (Reapproved 2004)Standard Specification forGlass Fiber Felt Thermal Insulation1This standard is issued under the fixed designation C 1086; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revi
2、sion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers glass fiber unsupportedneedled felt binder-free insulation for thermal insulation. Thismaterial is u
3、sed as the thermal insulation component in thefabrication of insulation systems for use on machinery andequipment, such as steam turbines, boilers, boiler feed pumps,and piping at temperatures up to 1200F (650C).1.2 This standard does not purport to address all of thesafety concerns, if any, associa
4、ted with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.3 The values stated in inch-pound units are to be regardedas the standard. The values given in parent
5、heses are providedfor information only.NOTE 1This standard is a consensus standard to provide a substitutefor military specification MIL-I-16411E.2. Referenced Documents2.1 ASTM Standards:2C 167 Test Methods for Thickness and Density of Blanketor Batt Thermal InsulationsC 168 Terminology Relating to
6、 Thermal InsulationC 177 Test Method for Steady-State Heat Flux Measure-ments and Thermal Transmission Properties by Means ofthe Guarded-Hot-Plate ApparatusC 390 Practice for Sampling and Acceptance of ThermalInsulation LotsC 411 Test Method for Hot-Surface Performance of High-Temperature Thermal In
7、sulationC 518 Test Method for Steady-State Thermal TransmissionProperties by Means of the Heat Flow Meter ApparatusC 1045 Practice for Calculating Thermal TransmissionProperties Under Steady-State ConditionsC 1058 Practice for Selecting Temperatures for Evaluatingand Reporting Thermal Properties of
8、Thermal InsulationD 578 Specification for Glass Fiber Strands2.2 U.S. Federal Standard:FED-STD-191 Textile Test Methods32.3 U.S. Military Standards:MIL-I-16411E Insulation Felt, Thermal, Glass Fiber3MIL-STD-1623 Fire Performance Requirements and Ap-proved Specifications for Interior Finish Materials
9、 andFurnishings (Naval Shipboard Use)33. Terminology3.1 Definitions:3.1.1 Terminology C 168 shall be considered as applying tothe terms used in this specification.3.1.2 Definitions in Specification D 578 shall be consideredas applying to the terms used in defining glass fiber composi-tion code, proc
10、ess, and fiber diameter.4. Classification4.1 Thermal insulation shall be glass fiber, unsupportedneedled felt insulation, for use on surfaces with temperaturesup to 1200F (650C).5. Ordering Information5.1 The purchase order or contract shall specify the follow-ing:5.1.1 Quantity of each thickness (1
11、0.1).5.1.2 Any special requirements for nonstandard sizes ordimensions (10.2 and 10.3).5.1.3 Any requirements for certification (19.1).5.1.4 Any special requirements for supplementary testingrequirements (9.1).6. Materials and Manufacture6.1 The material shall consist of 100 % glass fiber yarnsneedl
12、ed into insulation felts without the use of binders. Noorganic fibers and no glass or mineral shot shall be included inthe product. The insulation felt may be composed of laminatesformed without the use of binders. The glass fibers shall meetthe designation C, Continuous Filament Yarns, in accordanc
13、ewith Specification D 578 (see Note 2).1This specification is under the jurisdiction of ASTM Committee C16 onThermal Insulation and is the direct responsibility of Subcommittee C16.23 onBlanket and Loose Fill Insulation.Current edition approved April 1, 2004. Published May 2004. Originallyapproved i
14、n 1987. Last previous edition approved in 1996 as C 1086 96.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3
15、Available from Standardization Documents, Order Desk, Bldg. 4, Section D,700 Robbins Ave., Philadelphia, PA 19111-5094, ATTN: NPODS.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.2 The fiber diameter of the glass fiber yarns used
16、in thefinal product, when determined in accordance with the Fila-ment Diameter section of Specification D 578 shall conform tothe requirements of Table 1. The certification of the fineness offiber may be either by the felt manufacturer or by certificationof the glass yarn supplier and documentation
17、by the manufac-turer as to sources of supply.6.3 All materials used shall be asbestos-free.NOTE 2The fibers from glass composition designated as “E” glass(electrical glass) in the range from D through G meet the requirements ofTables 1 and 2.7. Physical Properties7.1 When tested in accordance with S
18、ection 16, the insula-tion shall conform to the physical requirements listed in Table2.8. Performance Characteristics8.1 Needled felt glass fiber insulation may be damaged ifany of the following conditions are encountered:8.1.1 Direct exposure to hydrofluoric acid.8.1.2 Prolonged direct exposure to
19、strong caustics.8.1.3 Prolonged exposure to boiling water.8.2 Conditions outlined in 8.1 are mentioned only to makethe user aware of such applications that require specialconsideration. Contact the insulation manufacturer for recom-mendations when the above conditions are anticipated.9. Other Requir
20、ements9.1 Supplementary requirements include qualification testsand acceptance tests to special standards. These supplementaryrequirements may be made by agreement to the supplier andthe purchaser only when specified in the purchase order orcontract.10. Standard Sizes and Dimensions10.1 ThicknessThe
21、 insulation shall be furnished in thethicknesses shown in Table 3.10.2 Insulation LengthUnless otherwise specified, theinsulation shall be furnished in rolls of the lengths given inTable 3.10.3 Insulation WidthUnless otherwise specified (5.1.2),the width of the insulation shall be 60 in. (1.52 m).10
22、.4 Nominal Weight per AreaThe insulation shall befurnished in the weight per area shown in Table 4.11. Dimensional Tolerances11.1 Thickness ToleranceThe average thickness as deter-mined in accordance with 16.1.1 shall be within 60.125 in.(3.2 mm) of the specified thickness.11.2 Mass per Area Toleran
23、ceThe average weight perarea shall be within 610 % of that specified in Table 4.11.3 Insulation Length/ToleranceThe tolerance on thelengths, listed in Table 3, shall be 6 in. (152 mm), withexcess permitted. A roll may either contain a maximum of onefull thickness splice or consist of a maximum of tw
24、o pieces.11.4 WidthThe width shall be within 0.5 in. (13 mm),to +1.0 in. (25 mm) of the specified width.12. Workmanship, Finish, and Appearance12.1 Since some requirements for this material are noteasily defined by a numerical value, the insulation shall nothave visible defects that will adversely a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC108619962004STANDARDSPECIFICATIONFORGLASSFIBERFELTTHERMALINSULATION 玻璃纤维 油毛毡 绝缘 标准规范 PDF

链接地址:http://www.mydoc123.com/p-463299.html