ASTM C1052-2014 Standard Practice for Bulk Sampling of Liquid Uranium Hexafluoride《液体六氟化铀散装取样标准操作规程》.pdf
《ASTM C1052-2014 Standard Practice for Bulk Sampling of Liquid Uranium Hexafluoride《液体六氟化铀散装取样标准操作规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1052-2014 Standard Practice for Bulk Sampling of Liquid Uranium Hexafluoride《液体六氟化铀散装取样标准操作规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1052 14Standard Practice forBulk Sampling of Liquid Uranium Hexafluoride1This standard is issued under the fixed designation C1052; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number i
2、n parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers methods for withdrawing represen-tative samples of liquid uranium hexafluoride (UF6) from bulkquantities of the material.
3、Such samples are used for determin-ing compliance with the applicable commercial specification,for example Specification C787 and Specification C996.1.2 It is assumed that the bulk liquid UF6being sampledcomprises a single quality and quantity of material. Thispractice does not address any special a
4、dditional arrangementsthat might be required for taking proportional or compositesamples. When the sampled bulk material is being added toUF6residues already in a container (“heels recycle”) additionalarrangements are required to avoid cross contamination of thebulk UF6, these are addressed in the a
5、ppropriate section (8.2)of Specifications C787 and C996.1.3 The number of samples to be taken, their nominalsample weight, and their disposition shall be agreed uponbetween the parties.1.4 The scope of this practice does not include provisionsfor preventing criticality incidents.1.5 This standard do
6、es not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Sta
7、ndards:2C787 Specification for Uranium Hexafluoride for Enrich-mentC996 Specification for Uranium Hexafluoride Enriched toLess Than 5 %235U2.2 Other Documents:USEC-651 Uranium Hexafluoride: A Manual of Good Han-dling Practices3ANSI N14.1 Uranium Hexafluoride: Packaging for Trans-port4ISO/DIS 7195 Pa
8、ckaging of Uranium Hexafluoride (UF6)for Transport43. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 containerthe bulk vessel either holding or receivingby transfer, the UF6to be sampled; it may consist of, forexample, a fixed vessel in a UF6handling plant or a cylinder tobe use
9、d for the transport of UF6.3.1.2 sample bottlethe small vessel into which the sampleof UF6is withdrawn for transfer to the laboratory for charac-terization.4. Summary of Practice4.1 Two methods of withdrawing a sample are described,namely: (1) direct withdrawal from a filled container and (2)withdra
10、wal from the inlet-line during the filling of a containerby liquid transfer. The first method involves tilting or turningthe container in such a way that its valve is below the surfaceof the liquefied UF6, and dependent on the equipment, thisrequires that the container holds more than a specified mi
11、ni-mum quantity of UF6. Liquid UF6is withdrawn into agraduated volume and then transferred to the respective samplebottle(s). In the second method, a small proportion of the UF6flowing from one container to another is withdrawn into agraduated volume and then transferred to the respective samplebott
12、le(s).4.2 For both methods of sampling, the presence of residuesmay have significant implications for the quality of the UF6.For safety and quality reasons, containers and bottles shall beclean, dry, and empty before filling.4.3 Various types of sample bottles are in use and aredescribed in detail i
13、n the applicable national and international1This practice is under the jurisdiction of ASTM Committee C26 on NuclearFuel Cycle and is the direct responsibility of Subcommittee C26.02 on Fuel andFertile Material Specifications.Current edition approved Jan. 15, 2014. Published February 2014. Originall
14、yapproved in 1985. Last previous edition approved in 2007 as C1052 01 (2007).DOI: 10.1520/C1052-14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Doc
15、ument Summary page onthe ASTM website.3Available from United States Enrichment Corp., 6903 Rockledge Dr., Bethesda,MD 20817.4Available from American National Standards Institute, 11 W. 42nd St., 13thFloor, New York, NY 10036.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Cons
16、hohocken, PA 19428-2959. United States1standards, for example, ANSI N14.1 and ISO/DIS 7195. For agiven type of sample bottle, the detailed configuration, forexample, valve orientation, terminal fittings, and the like, mayvary. Hence, the type and configuration of bottles to be used forthe withdrawal
17、 of samples shall be agreed upon between theparties.5. Significance and Use5.1 Uranium hexafluoride is normally produced and handledin large (typically 1- to 20-ton) quantities and must, therefore,be characterized by reference to representative samples. Thequantities involved, physical properties, c
18、hemical reactivity,and hazardous nature of UF6are such that for representativesampling, specially designed equipment must be used andoperated in accordance with the most carefully controlled andstringent procedures. This practice indicates appropriateprinciples, equipment, and procedures currently i
19、n use for bulksampling of liquid UF6. It is used by UF6converters, enrichers,and fuel fabricators to review the effectiveness of existingprocedures or as a guide to the design of equipment andprocedures for future use.5.2 It is emphasized that this practice is not meant to addressconventional or nuc
20、lear criticality safety issues.6. Hazards6.1 Because of its chemical, radiochemical, and toxicproperties, UF6is a hazardous material. UF6is very reactiveand corrosive. It reacts readily with water, atmosphericmoisture, certain metals, and many organic materials. Forreasons of safety and to avoid con
21、tamination, precautions mustbe taken to avoid contact with such materials. Suitable han-dling procedures are described in USEC-651.7. Principles7.1 The essential purpose of the sample is to be represen-tative of the bulk material for the purpose of determiningcompliance with the applicable material
22、specification. Toensure that the sample is representative for this purpose, certainprinciples, as described below, must be observed.7.2 Special attention must be given to ensuring that the bulkmaterial from which the sample is withdrawn is homogeneous,particularly in those circumstances when it has
23、been preparedby the blending together of materials having different compo-sitions. In practice, the low viscosity, and hence easy mobility,of liquid UF6facilitates the process of homogenization by theaction of convection currents within the bulk upon heating. Itis necessary to determine and establis
24、h for each set of samplingequipment the physical conditions, normally a combination ofthe minimum time and temperature for which liquefied ura-nium hexafluoride is held, which guarantee homogeneity of thebulk UF6.7.3 The sampling equipment is fabricated to appropriatehigh standards of vacuum integri
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC10522014STANDARDPRACTICEFORBULKSAMPLINGOFLIQUIDURANIUMHEXAFLUORIDE 液体 氟化 散装 取样 标准 操作规程 PDF

链接地址:http://www.mydoc123.com/p-463157.html