《ASTM B869-2007(2013) Standard Specification for Copper-Clad Steel Electrical Conductor for CATV Drop Wire《有线电视(CATV)停经片用包铜钢电导线的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM B869-2007(2013) Standard Specification for Copper-Clad Steel Electrical Conductor for CATV Drop Wire《有线电视(CATV)停经片用包铜钢电导线的标准规格》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B869 07 (Reapproved 2013)Standard Specification forCopper-Clad Steel Electrical Conductor for CATV Drop Wire1This standard is issued under the fixed designation B869; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers 21 % conductivity hard-drawnround copper-clad steel wire for coaxial cable center c
3、onduc-tors (Note 1).NOTE 1Wire ordered to this specification is not intended for redraw-ing since it is furnished in the hard-drawn temper. If wire is desired for thepurpose, the manufacturer should be consulted.1.2 The values stated in inch-pound units are to be regardedas standard. The values give
4、n in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.2. Referenced Documents2.1 The following documents, of the issue in effect on thedate of material purchase, form a part of this specification tothe extent referenced herein.
5、2.2 ASTM Standards:2B193 Test Method for Resistivity of Electrical ConductorMaterialsB258 Specification for Nominal Diameters and Cross-SectionalAreas ofAWG Sizes of Solid Round Wires Usedas Electrical Conductors2.3 NIST Document:3NBS Handbook 100Copper Wire Tables3. Ordering Information3.1 Orders f
6、or material under this specification shall includethe following information:3.1.1 Quantity of each size;3.1.2 Wire size: diameter in inches (see 5.1 and Table 1);3.1.3 Package size (see 15.1);3.1.4 Special package marking, if required (Section 15); and3.1.5 Place of inspection (13.2).4. Material4.1
7、The wire shall be composed of a steel core with asubstantially uniform and continuous copper cladding thor-oughly bonded to it throughout.4.2 The finished copper-clad steel wire shall conform to therequirements in this specification.5. Dimensions and Permissible Variations5.1 The size shall be expre
8、ssed as the diameter of the wirein decimal fractions of an inch, using four places of decimals,that is, in tenths of a mil (Note 2).NOTE 2The values of wire diameters in Table 1 and Table 2 are givento the nearest 0.0001 in. (0.0025 mm) and correspond to the standard sizesgiven in Specification B258
9、. In specifying diameters of wire or inspectingwire, the diameter should also be expressed to the fourth decimal place.An excellent discussion of wire gages and related subjects is contained inNBS Handbook 100.5.2 Within the range of diameters included in Table 1, thewire shall not vary from the spe
10、cified diameter by more than61 %, expressed to the nearest 0.0001 in. (0.0025 mm).5.3 Ten percent, but not less than five reels (or all, if the lotis less than five), from any lot of wire shall be gaged. All reelsshall be gaged if any of the selected reels fail to conform to therequirements for diam
11、eter.6. Workmanship, Finish, and Appearance6.1 The surface of the wire shall be free from imperfectionsand be consistent with good commercial practice.7. Tensile and Elongation Properties7.1 The wire shall conform to a minimum tensile require-ment of 120 000 psi (827 MPa) and a minimum elongationreq
12、uirement of 1.0 %.7.2 Tension tests shall be made on representative samples.Unless otherwise agreed upon between the manufacturer andthe purchaser, the elongation shall be determined by measure-ments made between the jaws of the testing machine. The zerolength shall be the distance between the jaws
13、when a load equalto 10 % of the specified tensile strength has been applied, andthe final length shall be the distance between the jaws at thetime of rupture. The zero length shall be as near 10 in. (2541This specification is under the jurisdiction of ASTM Committee B01 onElectrical Conductorsand is
14、 the direct responsibility of Subcommittee B01.06 onComposite Conductors.Current edition approved April 1, 2013. Published April 2013. Originallyapproved in 1996. Last previous edition approved in 2007 as B869 07. DOI:10.1520/B0869-07R13.2For referenced ASTM standards, visit the ASTM website, www.as
15、tm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from National Institute of Standards and Technology (NIST), 100Bureau Dr., Stop 1070, Gaithersburg, MD 20899-107
16、0, http:/www.nist.gov.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1mm) as practicable. The fracture shall be between the jaws ofthe testing machine and not closer than 1 in. (25.4 mm) toeither jaw. The elongation as thus determined
17、 shall not be lessthan 1.0 %. See Table 2 for related breaking strengths.7.3 When agreed upon between the manufacturer and thepurchaser, the elongation may be measured by means of anextensometer suitable for measuring elongation in 10 in. (250mm) and having a vernier reading to 0.01 in. (0.25 mm)att
18、ached to the test specimen at a tension load of approximately10 % of rated strength. The elongation as thus determined shallnot be less than 1.0 %. If the fracture occurs before the 1.0 %elongation requirement and outside the two attachments of theextensometer to the specimen, this sample shall be d
19、isregardedand a retest shall be performed.7.4 RetestIf, upon testing a sample from any coil or spoolof wire, the results do not conform to the tensile requirementsprescribed in 7.1 and the elongation requirements of 7.4, twoadditional samples shall be tested, and the average of the threetests shall
20、determine the acceptance or rejection of the coil orspool.NOTE 3The approximate properties of 21 % conductivity hard drawncopper-clad steel wire are shown in Table 1 for the information of the userof this specification.8. Torsion Test8.1 The wire shall withstand, without fracture, not less than20 to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB86920072013STANDARDSPECIFICATIONFORCOPPERCLADSTEELELECTRICALCONDUCTORFORCATVDROPWIRE 有线电视 CATV 停经片

链接地址:http://www.mydoc123.com/p-462588.html