1、A.1ASHRAE HANDBOOKAdditions and CorrectionsThis report includes additional information, and technical errorsfound between June 15, 2009, and April 3, 2012, in the SI editionsof the 2009, 2010, and 2011 ASHRAE Handbook volumes. Occa-sional typographical errors and nonstandard symbol labels will becor
2、rected in future volumes. The most current list of Handbookadditions and corrections is on the ASHRAE Web site(www.ashrae.org).The authors and editor encourage you to notify them if youfind other technical errors. Please send corrections to: HandbookEditor, ASHRAE, 1791 Tullie Circle NE, Atlanta, GA
3、 30329, ore-mail mowenashrae.org. 2009 FundamentalsContributors List. For Ch. 15, add the following contributors:Hakim Elmahdy, National Research Council of Canada; BrianCrooks; John L. Wright, University of Waterloo; and William R.McCluney, SunPine Consulting.p. 1.4, Table 2. Correct values for ssf
4、or 40 to 64C are providedbelow.pp. 1.6-1.7, Table 3. In the column headings, change “Sat. Solid”to “Sat. Liquid” in three places.p. 1.9, 1st col. The reference to Equation (38) in Chapter 5 shouldbe to Chapter 6.p. 1.12, Example 3. Reference to Table 2 should be to Table 3.Fig. 2 should be Fig. 3, a
5、nd Fig. 3 should be Fig. 2.p. 1.13, Example 5. The reference to Table 2 should be to Table 3.p. 1.14, Example 5. The solution to the equation should be 15 gw/s,or 0.015 kgw/s. p. 3.2, 2nd col., last paragraph. Delete the second instance of thefollowing sentence: “The terms EMand HM(= EM/g) are defin
6、ed aspositive, and represent energy added to the fluid by pumps or blow-ers.”p. 4.19, Table 8, Eq. (T8.12). Change 0.37 to 0.037.p. 4.22, Table 10. Correct Eqs. (T10.1) and (T10.7) as follows:(T10.1)(T10.7)p. 4.24, Table 11. In the Muley and Manglik (1999) equation forNu, the last line should read “
7、 Re0.7280.0543 sin(90)/45+3.7.”p. 9.17, between Eqs. (64) and (65). The reference to Equation (58)should be to Equation (60).p. 9.19, Eq. (79). The equation should be toc= 17.8 + 0.31tout.p. 13.14, 2nd col., 3rd full paragraph. The equation should read.p. 14.1, 1st paragraph. The StationFinder utili
8、ty is included onlywith the HandbookCD+ version of this chapter, not with the CD-ROM included with the print edition.p. 14.7, Eq. (5). Add a closing parenthesis at the end of the equation.p. 14.9, Eq. (20). The first operator should be +, not .Ch. 14, Appendix: Design Conditions for Selected Locatio
9、ns,and complete listing of stations on CD. Richmond InternationalAirport belongs in Virginia, not North Carolina. The main entry forTaiwan should read “Taiwan.”Ch. 14, Station List and Climatic Design Conditions Tables(available on the CD-ROM). Richmond International Airportbelongs in Virginia, not
10、North Carolina. In the Russian Federation,station UST-ISIM, WMO ID 283820, the longitude should be 71.18E. Hong Kong International (WMO ID 450070) and Hong KongObservatory (WMO ID 450050) should appear under Hong Kongrather than China. Correct the following latitudes and longitudes:p. 15.11, Example
11、 2, Solution. The second reference to Table 4should be to Table 1.p. 15.11, Example 3, Solution. The mullions should be 80 mm.p. 15.16, 1st col., top. Add “when” before “greater accuracy isdesired.”p. 15.29, Table 12. Change the title to read, “Solar Heat Gain Coef-ficients and U-Factors for Standar
12、d hollow Glass Block Wall Panels.”p. 15.60, Symbols. Add the definition “FR= radiant fraction.”Temp. t, C ssTemp. t, Css40 0.5650 66 2.011741 0.5925 67 2.122042 0.6213 68 2.239843 0.6514 69 2.365944 0.683070 2.501145 0.7162 71 2.646446 0.7509 72 2.802847 0.7874 73 2.971548 0.8256 74 3.153949 0.8658
13、75 3.351750 0.908176 3.566851 0.9525 77 3.801452 0.9993 78 4.058153 1.0485 79 4.340154 1.100380 4.651155 1.1549 81 4.995656 1.2126 82 5.379457 1.2734 83 5.809158 1.3377 84 6.293359 1.4056 85 6.843060 1.4775 86 7.472161 1.5537 87 8.198762 1.6345 88 9.047263 1.7203 89 10.050864 1.8114 90 11.255865 1.9
14、084Station WMO ID Latitude LongitudeSomerset, KY 724354 37.054N 84.601WSouth St. Paul, MN 726603 44.857N 93.018WDyersburg, TN 723347 36.000 N 89.400W1expN 1 cr+1 cr+-1expcrcr- PRairT=A.2 20092011 ASHRAE Handbook Additions and Corrections (SI)p. 15.62, References. Add the following source before LBL
15、2003:Laoudi, A., A.D. Galasiu, M.R. Atif, and A. Haqqani. 2003. SkyVision: Asoftware tool to calculate the optical characteristics and daylighting per-formance of skylights. Building Simulation, 8th IBPSA Conference,Eindhoven, Netherlands, pp. 705-712.p. 16.7, Eq. (26). On the third line, change “Cp
16、(3) Cp(4)” to“Cp(3) + Cp(4).”p. 16.23, Eq. (48). The equation should use the absolute value of t.p. 17.5, Eq. (8), definition for AL. Discharge coefficient CDshould equal 1, and the unit for ALis cm2.p. 17.7. For Eq. (11), the correct equation is as follows:(11)In the definitions after Eq. (18), cha
17、nge qvnt,lto qvi.l.p. 17.8, Eq. (21). The closing parenthesis should be at the end of theequation.p. 18.2, 2nd col., Cooling Load Calculations in Practice section.On the third line, change “filtration” to “infiltration.”pp. 18.8-18.11, Tables 5A to 5E. Items with an asterisk appear onlyin Swierzycna
18、 (2009); all others appear in both Swierzycna (2008)and (2009). In the heading for Table 5E, change “Btu/h” to “W.”p. 18.14, Eq. (9). In the definitions, change 0.24 to 1.006, and 0.45to 1.84.p. 18.31, Eq. (39). The denominator of the first fraction should be(z2 z1).p. 18.31, Eq. (40). The correct e
19、quation is as follows:(40)p. 18.32, Table 24. In column 1, change the second occurrence of“200 mm” to “100 mm.”p. 18.33, 2nd col. In the list of variables under item 2, Tr= room orreturn air temperature, C.p. 18.37, 1st col., bottom half. For Qc15, the equation should be(440)(52%) = 229 W.p. 18.43,
20、Table 31. For the radiant and convective columns, use thefollowing data.p. 18.42, Part 4. Change “the addition of a overhang” to “the addi-tion of a 3 m overhang.”p. 19.18, Eqs. (55), (57), and (59). Multiply the right-hand side ofthe equation by the conversion factor 86 400 s/day. For Eq. (57),also
21、 change hto c.p. 20.12, Fig. 10. The correct figure is shown above.p. 20.13, 2nd col., Air Diffusion Performance Index (ADPI), 1stparagraph. The reference should be to Equation (15).p. 20.14, 2nd col., Convective Flows Associated with Space HeatSources, last paragraph. The reference should be to Equ
22、ation (12). p. 21.6, Table 1. Units for Absolute Roughness should be mm.p. 21.33, Table for ED5-1, Wye, 30, Converging. In the expres-sion centered over the table columns, change Qbto Qs.pp. 21.41-44. In the table titles, change “D5-3” to “ED5-3.”pp. 21.42-44, Tables for ED5-3, Dc 250 mm, Converging
23、. In theexpressions centered over the table columns, change Qbto Qs(threeplaces).p. 21.44, Figures for ED5-6 and ED5-9. The correct figures areshown on p. A.3, left column.pp. 21.45 (bottom table) and 21.46 (top table). Change “Cb1Val-ues” to “Cb2Values.”p. 23.2, Table 2. The heading for the rightmo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASHRAEHVACSYSTEMSANDEQUIPMENTSIADDANDCORR2012ADDITIONSANDCORRECTIONSPDF

链接地址:http://www.mydoc123.com/p-455085.html