ASHRAE 62 1 USERS MANUAL-2010 Ventilation for Acceptable Indoor Air Quality (Includes Access to Additional Content).pdf
《ASHRAE 62 1 USERS MANUAL-2010 Ventilation for Acceptable Indoor Air Quality (Includes Access to Additional Content).pdf》由会员分享,可在线阅读,更多相关《ASHRAE 62 1 USERS MANUAL-2010 Ventilation for Acceptable Indoor Air Quality (Includes Access to Additional Content).pdf(181页珍藏版)》请在麦多课文档分享上搜索。
1、 Access to Additional Content for ASHRAE 62.1 Users Manual, Dated: 2010 (Click here to view the publication) This Page is not part of the original publication This page has been added by IHS as a convenience to the user in order to provide access to additional content as authorized by the Copyright
2、holder of this document Click the link(s) below to access the content and use normal procedures for downloading or opening the files. ASHRAE 62.1 UM Extra Files Information contained in the above is the property of the Copyright holder and all Notice of Disclaimer telephone +1-404-636-8400; www.ashr
3、ae.org. 2011 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. 1791 Tullie Circle Atlanta, GA 30329 All rights reserved. Printed in the United States of America. ISBN 978-1-933742-98-4 ASHRAE has compiled this publication with care, but ASHRAE has not investigated, and
4、ASHRAE expressly disclaims any duty to investigate any product, service, process, procedure, design, or the like that may be described herein. The appearance of any technical data or editorial material in this publication does not constitute endorsement, warranty, or guaranty by ASHRAE of any produc
5、t, service, process, procedure, design, or the like. ASHRAE does not warrant that the information in this publication is free of errors, and ASHRAE does not necessarily agree with any statement or opinion in the publication. The entire risk of the use of any information in this publication is assume
6、d by the user. No part of this book may be reproduced without permission in writing from ASHRAE, except by a reviewer who may quote brief passages or reproduce illustrations in a review with appropriate credit; nor may any part of this book be reproduced, stored in a retrieval system, or transmitted
7、 in any way for or by any meanselectronic, photocopying, recording, or otherwithout permission in writing from ASHRAE. Requests for permission should be submitted at www.ashrae.org/permissions. Any updates/errata to this publication will be posted on the ASHRAE Web site at www.ashrae.org/publication
8、updates. 2011 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (www.ashrae.org). For personal use only. Additional reproduction, distribution, or transmission in either print or digital form is not permitted without ASHRAEs prior written permission.Users Manual for ANS
9、I/ASHRAE Standard 62.1-2010 Explains the standard through the use of sample calculations and examples; Encourages the user to apply the principles of good indoor air quality and effective ventilation when designing buildings and building systems; Provides useful reference material to assist designer
10、s in efficiently completing a successful and compliant design; Gives guidance to building operation and maintenance personnel. This Manual also instructs the user in the application of tools used for compliance with Standard 62.1-2010. In particular, three newly-revised spreadsheets are distributed
11、with this Users Manual that assists in the Ventilation Rate Procedure calculations. Audience This Users Manual is intended to be used by: Architects and engineers who must apply the standard to the design of their buildings; Those manufacturers of systems and components who choose to provide the ind
12、ustry with complying equipment; Plan examiners and field inspectors who will be charged with enforcing the standard in areas where it is adopted as code; General and specialty contractors who must construct buildings in compliance with the standard; and Operators and maintainers who must ensure the
13、compliance of the building throughout its lifespan. Addenda Standard 62.1 is a dynamic document undergoing continuous maintenance, with addenda, errata, and interpretations issued throughout its life. As of the publication date of this Users Manual, there have been no approved addenda to Standard 62
14、.1-2010. In the future, however, the ASHRAE committee responsible for maintaining the standard (SSPC 62.1) is expected to approve addenda. When using this Manual to comply with a code based on Standard 62.1, check whether any addenda have been incorporated in that code, and read those addenda carefu
15、lly. Addenda are posted on the ASHRAE Web site, at www.ashrae.org. Also, if the adopted code references a version of the standard prior to 2010, then the information contained within this Manual may not apply. Official Interpretations The Standing Standards Project Committee (SSPC) 62.1 provides off
16、icial interpretations of the standard upon written request. Interpretations are restricted to the words contained 2011 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (www.ashrae.org). For personal use only. Additional reproduction, distribution, or transmission in ei
17、ther print or digital form is not permitted without ASHRAEs prior written permission.Page 2 Preface within the standard itself and cannot encompass design reviews and/or proposals for changes. Address requests for interpretations to the Manager of Standards, ASHRAE, 1791 Tullie Circle, NE, Atlanta,
18、GA, 30329-2305. The SSPC usually assigns the request to a subcommittee, which then reviews it and develops an interpretation. This interpretation is then voted on by the full committee. A common timeframe for a response is six to twelve months. See informative Appendix G of the standard for more inf
19、ormation on requesting an interpretation. Interpretations are also posted on the ASHRAE Web site, at www.ashrae.org. Standard 62.1 Organization Standard 62.1 is divided into nine sections and eight appendices. Sections 1, 2, and 3 are administrative and do not contain any requirements: Section 1Purp
20、ose states the purpose of the standard. Section 2Scope describes where the standard does and does not apply. Section 3Definitions provides definitions of terms that are used throughout the standard. Sections 4 through 8 are the technical sections of the standard and contain the technical requirement
21、s for the design, installation and operation of ventilation systems in buildings, as well as additional requirements that apply to features of the building other than these systems. Section 4Outdoor Air Quality requires that the site and the quality of outdoor air be evaluated to determine whether s
22、pecial design considerations such as cleaning of the outdoor air are needed. Section 5Systems and Equipment includes specific requirements for the design of ventilation systems in buildings, as well as the building envelope. Section 6Procedures presents methods for determining the volumetric airflow
23、 rate of outdoor air that must be brought into the building through the HVAC system(s), as well as requirements for filtration and cleaning of the outdoor air. Section 7Construction and System Startup contains requirements that apply during the construction and startup phase of new construction proj
24、ects. Section 8Operations and Maintenance outlines requirements for the operation and maintenance of building ventilation systems after they are constructed. In addition to the nine primary sections, the standard contains a Foreword and ten appendices. The Foreword provides a historical perspective
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASHRAE621USERSMANUAL2010VENTILATIONFORACCEPTABLEINDOORAIRQUALITYINCLUDESACCESSTOADDITIONALCONTENTPDF

链接地址:http://www.mydoc123.com/p-454392.html