1、AECMA PREN*K2350 89 LOL23LL 0007854 2 i-; prEN 2360 A.E.C.M.A. STANDARD Edition 1 NORME A.E.C.M.A. A.E.C.M.A. NORM January 19EB - EDITE PAR LASSOCIATION EUROPEENNE DES CONSTRUCTEURS DE MASRIEL AEROSPATIAL 88. boulevard Malerherber. 76008 PARIS -TEL 46.63-82-86 UDC : 621.31 6.67 : 629.7 Key words : A
2、ircraft industry, aircraft equipment, circuit breaker, msnufecturlng requirement, specification, test, testing condition, environment, marking. ENOLISH VERSION Aerospacb series Circuit bmaken Technical 8p;ecification Srie e6rospatlale Disjoncteurs Spcification technique Luft- und Raumfahrt Schutzsch
3、alter technlrche Lleferbedlngungen . Ths .Aerospace series. standardhas been drawn up under the rasponribility of AECMA (Association Europenne des Constructeurs de Matriel Arospetiall. It it published on yellow paper n three equivalent versions (English. French, Gernfan). It will be submined as a dr
4、af European Standard to CEN (European Committee for Standardization) for final voie. .- The equivalent version8 in Frencb German languigo8 can e MfrO.V8lh1rf It - FRANCE /il nwmn la- AECMA PREN82350 89 I 10L23LL 0007855 4 0 prEN 2350 Page 2 CONTENTS 1 Scope and fleld of appllcatlon 2 References 3 De
5、f In1 tlons 4 Deslgn 5 Tests - Recplrements - Procedures -I Evaluation 6 Qual If Icatlon 7 Perlodlc tests to malntain quallflcation 8 Acceptance 9 Marking AECMA PREN*Z350 89 E 1012311 0007856 b T 1 Scope and field of application prEN 2350 Page 3 This standard gives design information and specifies t
6、est methods for aircraft circuit breakers covered by EN standards. It is applicable if it is referred to in these standards. 2 References IS0 2669 IS0 2859-1974 IS0 7137 IEC Publication 50 EN 2000 MIL-A-8243D MIL-H-5606E MIL-L-23699C M I L-C- 2 5769 J MI L- L-78085 MIL-L-7870A MIL-G-5572F MI L-H-832
7、82C SAE AS 1241 3 Definitions - Environmental tests for aircraft equipment - Part 3.2 : Steady state acceleration Sampling procedures and tables for inspection by attributes Aircraft - Environmental conditions and test procedures for airborne equipment International electrotechnical vocabulary Chapt
8、er 441 : Switchgear, controlgear and fuses Aerospace series - Quality assurance requirements for the manufacture and procurement of EN aerospace standard products Anti-icing and deicing - Defrosting fluid Hydraulic fluid, petroleum base, aircraft, missile, and ordnance Lubricating oil, aircraft turb
9、ine engine, synthetic base Cleaning compound, aircraft surface, alkaline waterbase Lubricating oil, aircraft turbine engine, synthetic base Lubricating oil, general purpose, low temperature Gasol i ne avi at i on grades 80/87 , 100/30, 115/145 Hydraulic fluid, fire resistant, synthetic hydrocarbon b
10、ase, aircraft, metric - Fire resistant phosphate ester, hydraulic fluid for aircraft - Circuit breaker with “trip-free release“ : A circuit breaker in which the “open“ command takes precedence over the “close“ command, i.e when the electrical trip condition is reached and pressure is exerted on the
11、depressed actuator button, the circuit is sti 11 automatically opened. - Poles of a circuit breaker A circuit breaker pole denotes any main circuit from the input to the pertinent output termi na1 . AECMA PREN*Z350 89 LOL231L 0007857 8 S prEN 2350 Page 4 The parts of each current path (contacts, sen
12、sors, switching parts) are independent and electrically isolated. There may be 1, 2 or 3 poles independently of any auxiliary circuits. - Current rating (In) : The current rating (In) of a circuit breaker is the current in amperes for which the circuit breaker has been designed and designated. Trip
13、characteristics and test values are based on the current rating. - Voltage ratings : Voltage ratings are the voltage levels in volts for which the circuit breaker is designed. Insulation values and test voltages are related to these rated voltages. - Indication of current and voltage values Unless o
14、therwise. specified, the a.c. voltage and a.c. current values shown are r.m.s. values. For other definitions, see IEC Publication 50 - Chapter 441. 4 Design 4.1 Insulating housing In addition to the switching mechanism, the insulating housing shall incorporate the connecting and mounting systems. 4.
15、2 Trip-free mechanism The circuit breaker shall be designed to permit trip-free release, i.e. so that it is switched off at overload and remains switched off even when the button is held in the closed position. Resetting of the circuit breaker shall be possible only after complete release of the act
16、uator button. In no case shall operation under these conditions affect the further serviceability of the circuit breaker. All poles of a multi-pole circuit breaker shall trip on single or multi-phase overload. The time lag between opening of the first and last pole shall not exceed 10 ms. 4.3 Mounti
17、ng All visible parts shall be black and non-reflective. 4.4 Electrical connection components These shall be suitable to fit the cable lugs (or contacts). I AECMA PREN*2350 89 1012311 0007858 T I prEN 2350 page 5 4.5 Actuator button In the closed position the visible part of the actuator button shall
18、 be black. In the “off“ (open) position a white strip shall be exposed. The outer part of this button shall be insulated from all live parts. In no case shall the actuator button remain in an intermediate position or give an incorrect indication of the switching condition of the circuit breaker. It
19、shall not be removable. - The circuit breaker contacts shall be closed by pushing the actuator button. - The circuit breaker contacts shall be opened by pulling the actuator button. The current rating of the circuit breaker shall be indicated indelibly in white on the top of the actuator button. Arr
20、angement of the digits is indicated in the product standard. 4.6 Calibration safety device The circuit breaker shall be designed in such a way that the calibration cannot be interfered with without breaking a seal. 4.7 Leakage paths Leakage paths and the minimum distance to be observed between live
21、parts and all other parts of the circuit breaker in non-insulating materials and between live parts of opposite polarity shall be sufficient to avoid damage and spark- over under all operating and ambient conditions. 4.8 Insulants Insulating parts shall be of non-inflammable or self-extinguishing ma
22、terials and shall not emit noxious or explosive vapours. They shall be resistant to fungus growth and the effects of micro-organisms. Protective coatings and materials which may chip, crack or shatter shall not be used. 4.9 Protection against corrosion All metal parts shall be either resistant to or
23、 protected against corrosion, In case of contact between dissimilar metals they shall be protected against electrochemical corrosion. Where bimetals are used, any corrosion which may occur shall not affect the proper function of the circuit breaker. AECMA PREN*Z350 89 E 1012311 0007859 II E prEN 235
24、0 Page 6 4.10 Fasteners Screws and nuts shall be so locked that the connections cannot be damaged. 5 Tests - Requirements 5.1 General 5.1.1 Un1 ess ot herwi se Ambient temperature 23 - Procedures - Evaluation indicated, measurement conditions are as fol lows : t 5“ c _ . - -_ - _- -* _ Pressure 840
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASDSTANPREN23501989AEROSPACESERIESCIRCUITBREAKERSTECHNICALSPECIFICATIONEDITION1 航空航天 系列 断路器 技术规范 PDF

链接地址:http://www.mydoc123.com/p-450978.html