ASHRAE 16 ERTA-2015 Method of Testing for Rating Room Air Conditioners and Packaged Terminal Air Conditioners.pdf
《ASHRAE 16 ERTA-2015 Method of Testing for Rating Room Air Conditioners and Packaged Terminal Air Conditioners.pdf》由会员分享,可在线阅读,更多相关《ASHRAE 16 ERTA-2015 Method of Testing for Rating Room Air Conditioners and Packaged Terminal Air Conditioners.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、ERRATA SHEET FOR ANSI/ASHRAE STANDARD 16-1983 (RA 2014) Method of Testing for Rating Room Air Conditioners and Packaged Terminal Air Conditioners December 10, 2015 The corrections listed in this errata sheet apply to all copies of ANSI/ASHRAE Standard 16-1983 (RA 2014). The first printing is identif
2、ied on the outside back cover as “Product code: 86027 7/14”. Shaded items have been added since the previously published errata sheet dated October 6, 2015 was distributed. Page Erratum 7 Table 2 Data to be Recorded for Cooling Capacity Tests. In footnote “b” of Table 2 change “See 3.2.7” to “See 4.
3、2.7”. 8 6.2.1 and 6.2.2. Correct the equations and terms in Sections 6.2.1 and 6.2.2 as shown below (highlighted in yellow). (Note: Additions are shown in underline and deletions are shown in strikethrough.) 6.2 Cooling Capacity Calculations 6.2.1 Net total cooling effect on the room side, as tested
4、 in either the calibrated or balanced ambient room type calorimeter (Figures 1a and 1b), is calculated as follows: qtr = 3.41 SEr + (hw1 - hw2) wr + qlp + qlr (qtr = SEr + 1000 (hw1 - hw2) wr + qlp + qlr). where qtr = net total cooling effect as determined on room-side compartment, Btu/h (W). SEr =
5、sum of all power input to room-side compartment, W. hw1 = enthalpy of water or steam supplied to maintain humidity, Btu/lb (kJ/kg). If no water is introduced during the test, hw1 is taken at the temperature of the water in the humidifier tank of the reconditioning equipment. hw2 = enthalpy of conden
6、sed moisture leaving the room-side compartment, Btu/lb (kJ/kg). Since transfer of condensed moisture from room-side to outdoor-side compartment usually takes place within the air conditioner, with consequent difficulty in measuring its temperature, the temperature of the condensate may be assumed to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASHRAE16ERTA2015METHODOFTESTINGFORRATINGROOMAIRCONDITIONERSANDPACKAGEDTERMINALAIRCONDITIONERSPDF

链接地址:http://www.mydoc123.com/p-450209.html