AS NZS 61558 2 9-2003 Safety of power transformers power supply units and similar devices - Particular requirements for transformers for class III handlamps for tungsten filament l.pdf
《AS NZS 61558 2 9-2003 Safety of power transformers power supply units and similar devices - Particular requirements for transformers for class III handlamps for tungsten filament l.pdf》由会员分享,可在线阅读,更多相关《AS NZS 61558 2 9-2003 Safety of power transformers power supply units and similar devices - Particular requirements for transformers for class III handlamps for tungsten filament l.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、 AS/NZS 61558.2.9 AS/NZS 61558.2.9:2003 (IEC 61558-2-9:2002, MOD) Australian/New Zealand Standard Safety of power transformers, power supply units and similar products - Part 2.9: Particular requirements for transformers for class III handlamps for tungsten filament lamps (IEC 61558-2-9:2002, MOD) A
2、ccessed by ISONET - CHINA STATE BUREAU OF TECHNICAL SUPERVIS on 17 May 2007This standard was issued in draft form for comment as DR 02928 AS/NZS 61558.2.9:2003 This Joint Australian/New Zealand Standard was prepared by Joint Technical Committee EL/2 - Safety of household and similar electrical appli
3、ances and small power transformers. It was approved on behalf of the Council of Standards Australia on 15 April 2003 and by the Council of Standards New Zealand on 8 May 2003. It was published on 30 May 2003. The following interests are represented on Committee EL/2 Association of Certification Bodi
4、es Australian Chamber of Commerce and Industry Australian Electrical and Electronic Manufacturers Association Canterbury Manufacturers Association New Zealand Consumer Electronic Suppliers Association, Australia Electrical regulatory authorities, Australia Electrical test laboratories Electrical con
5、sultants Electricity Supply Association of Australia Institution of Engineers Australia Metal Trades Industries Association of Australia Ministry of Consumer Affairs, New Zealand Keeping Standards up-to-date Standards are living documents, which reflect progress in science, technology and systems. T
6、o maintain their currency, all Standards are periodically reviewed, and new editions are published. Between editions, amendments may be issued. Standards may also be withdrawn. It is important that readers assure themselves they are using a current Standard, which should include any amendments which
7、 may have been published since the Standard was purchased. Detailed information about joint Australian/New Zealand Standards can be found by visiting the Standards Australia web site at .au or Standards New Zealand web site at www.standards.co.nz and looking up the relevant Standard in the on-line c
8、atalogue. Alternatively, both organizations publish an annual printed Catalogue with full details of all current Standards. For more frequent listings or notification of revisions, amendments and withdrawals, Standards Australia and Standards New Zealand offer a number of update options. For informa
9、tion about these services, users should contact their respective national Standards organization. We also welcome suggestions for improvement in our Standards, and especially encourage readers to notify us immediately of any apparent inaccuracies or ambiguities. Please address your comment to the Ch
10、ief Executive of either Standards Australia International or Standards New Zealand at the address shown on the back cover. Accessed by ISONET - CHINA STATE BUREAU OF TECHNICAL SUPERVIS on 17 May 2007AS/NZS 61558.2.9:2003 (IEC 61558-2-9:2002, MOD) Australian/New Zealand Standard Safety of power trans
11、formers, power supply units and similar products - Part 2.9: Particular requirements for transformers for class III handlamps for tungsten filament lamps (IEC 61558-2-9:2002, MOD) Originated, in part, in Australia as AS C126-1939 Second edition C126 1958 Revised and redesignated AS 3126 1981 (withdr
12、awn 1989) Originated, in part, in Australia as AS C167-1962 Revised and redesignated AS 3167 1981 (withdrawn 1987) AS 3126 1981 and AS 3167 1981 were revised and redesignated AS 3108.1-1984, AS 3108.2-1984 and AS 3108.3 1984 Revised, amalgamated and redesignated AS 3108 1990 First published in New Z
13、ealand as NZS/AS 3108:1990 Jointly revised and redesignated AS/NZS 3108:1994 Jointly revised and redesignated, in part, as AS/NZS 61558.2.9:2003 COPYRIGHT Standards Australia/ Standards New Zealand All rights are reserved. No part of this work may be reproduced or copied in any form or by any means,
14、 electronic or mechanical, including photocopying, without the written permission of the publisher Published jointly by Standards Australia International Ltd GPO Box 5420,Sydney, NSW 2001 Australia, and Standards New Zealand Private Bag 2439,Wellington 6020, New Zealand ISBN 0 7337 5380 9Accessed by
15、 ISONET - CHINA STATE BUREAU OF TECHNICAL SUPERVIS on 17 May 20072 COPYRIGHT CONTENTS FOREWORD.3 1 Scope 5 2 Normative references .6 3 Definitions6 4 General requirements .6 5 General notes on tests6 6 Ratings 6 7 Classification6 8 Marking and other information.7 9 Protection against accessibility o
16、f hazardous live parts7 10 Change of input voltage setting.8 11 Output voltage and output current under load8 12 No-load output voltage8 13 Short-circuit voltage9 14 Heating 9 15 Short-circuit and overload protection.9 16 Mechanical strength .9 17 Protection against harmful ingress of dust, solid ob
17、jects and moisture .9 18 Insulation resistance and dielectric strength 9 19 Construction.9 20 Components.11 21 Internal wiring.11 22 Supply connection and other external flexible cables or cords11 23 Terminals for external conductors .12 24 Provision for protective earthing12 25 Screws and connectio
18、ns .12 26 Creepage distances, clearances and distances through insulation .12 27 Resistance to heat, abnormal heat, fire, and tracking 12 28 Resistance to rusting 12 Annexes .13 Annex C Creepage distances and clearances Material group II .13 Annex D Creepage distances and clearances Material group I
19、 13 Annex L Routine tests (production tests) .13 Annex ZZ (informative) Variations to IEC 61558-2-9:2002 for application in Australia and New Zealand .14 Table 101 Output voltages ratio for transformers for class III handlamps for tungsten filament lamps 9 Accessed by ISONET - CHINA STATE BUREAU OF
20、TECHNICAL SUPERVIS on 17 May 20073 COPYRIGHT STANDARDS AUSTRALIA / STANDARDS NEW ZEALAND _ SAFETY OF POWER TRANSFORMERS, POWER SUPPLY UNITS AND SIMILAR PRODUCTS Part 2.9: Particular requirements for transformers for class III handlamps for tungsten filament lamps FOREWORD This standard was prepared
21、by the Joint Standards Australia/Standards New Zealand Committee EL-002- Safety of Household and Similar Electrical Appliances and Small Power Transformers, to supersede AS/NZS 3108, Chapter 3, Section 4, two years from publication. The objective of this Standard is to provide manufacturers, designe
22、rs, regulatory authorities, testing laboratories and similar organizations with safety requirements for the design, manufacture and testing of safety isolating transformers for general use which can form the basis for approval by regulatory authorities This Standard forms the first edition of AS/NZS
23、 61558.2.9 Safety of power transformers, power supply units and similar products - Part 2.9: Particular requirements for transformers for class III handlamps for tungsten filament lamps. This Standard is an adoption with national modifications and contains the full text of the first edition of IEC 6
24、1558-2-9:2002, Safety of power transformers, power supply units and similar products - Part 2-9: Particular requirements for transformers for class III handlamps for tungsten filament lamps and has been varied as indicated to take account of Australian and New Zealand conditions. It is to be used in
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASNZS61558292003SAFETYOFPOWERTRANSFORMERSPOWERSUPPLYUNITSANDSIMILARDEVICESPARTICULARREQUIREMENTSFORTRANSFORMERSFORCLASSIIIHANDLAMPSFORTUNGSTENFILAMENTLPDF

链接地址:http://www.mydoc123.com/p-450179.html