ARMY UFGS-28 20 02-2008 CENTRAL MONITORING SERVICES FOR ELECTRONIC SECURITY SYSTEMS《电子安全系统中央监控服务》.pdf
《ARMY UFGS-28 20 02-2008 CENTRAL MONITORING SERVICES FOR ELECTRONIC SECURITY SYSTEMS《电子安全系统中央监控服务》.pdf》由会员分享,可在线阅读,更多相关《ARMY UFGS-28 20 02-2008 CENTRAL MONITORING SERVICES FOR ELECTRONIC SECURITY SYSTEMS《电子安全系统中央监控服务》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-28 20 02 (November 2008)-Preparing Activity: USACE SupersedingUFGS-13729 (April 2006)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated October 2008*SECTION TABLE OF CONTENTSDIVISION 28 - ELECTRONIC SAFETY AND SECURITYSECTION 28 20
2、 02CENTRAL MONITORING SERVICES FOR ELECTRONIC SECURITY SYSTEMS11/08PART 1 GENERAL1.1 REFERENCES1.2 SYSTEM DESCRIPTION1.2.1 General System Description1.2.2 Redundant Monitoring Facility1.3 SUBMITTALS1.4 QUALITY ASSURANCE1.4.1 Monitoring Facility Personnel Hiring Practices1.4.2 Monitoring Facility Ope
3、rator Qualifications1.4.2.1 Central Station Operator Certificates1.4.2.2 In-House Training1.4.3 Regulatory Requirements1.4.3.1 Security Alarm Systems1.4.3.2 Central Monitoring Facility Staffing1.4.3.3 Central Monitoring of High Security Assets1.4.4 Insurance1.4.5 Procedure Development Conference1.4.
4、5.1 Scheduling and Location1.4.5.2 Operating Procedure Plan1.4.5.3 Plan VerificationPART 2 PRODUCTS (NOT USED)PART 3 EXECUTION3.1 INTERFACE3.1.1 Alarm Signal Format3.1.2 Communication Means3.2 AUDIO VERIFICATION3.3 VIDEO VERIFICATION- End of Section Table of Contents -SECTION 28 20 02 Page 1Provided
5、 by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-28 20 02 (November 2008)-Preparing Activity: USACE SupersedingUFGS-13729 (April 2006)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated Octob
6、er 2008*SECTION 28 20 02CENTRAL MONITORING SERVICES FOR ELECTRONIC SECURITY SYSTEMS11/08*NOTE: This guide specification covers the requirements for central monitoring services for electronic security systems.Edit this guide specification for project specific requirements by adding, deleting, or revi
7、sing text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments and suggestions on this guide specification are welcome and should be directed to the tech
8、nical proponent of the specification. A listing of technical proponents, including their organization designation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).*PART 1 GENERAL*NOTE: This guide specification specifies mon
9、itoring facility criteria. This specification does not cover requirements pertaining to the installation of alarm systems at a protected site monitored by a central monitoring facility.A monitoring facility, as used in this document, is a building, an office, or a suite of offices that houses the se
10、curity system central station and monitoring personnel. In this type system, the operation of alarm devices and electrical circuits is automatically signaled to, recorded, maintained, and supervised from a central station with persons in attendance at all times. These persons monitor SECTION 28 20 0
11、2 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-the signals and dispatch the response force to any unauthorized entry into the protected area. Connection of alarm equipment to the central monitoring facility may be over leased telephone compa
12、ny lines.*1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Che
13、ck Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this se
14、ction of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.U.S. DEFENSE INTELLIGENCE
15、AGENCY (DIA)DIA DCID 6/9 (2002) Director of Central Intelligence Directive No. 6/9U.S. DEPARTMENT OF DEFENSE (DOD)DOD 5100.76-M (2000) Physical Security of Sensitive Conventional Arms, Ammunition, and ExplosivesDOD 5220.22-M (2006) National Industrial Security Program Operating Manual (NISPOM)UNDERW
16、RITERS LABORATORIES (UL)UL 1981 (2003) Central Station Automation SystemsUL 2050 (2003; 4th Edition) National Industrial Security SystemsUL 827 (1996; Rev thru Jan 2007) Central Station Alarm ServicesSECTION 28 20 02 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without
17、license from IHS-,-,-1.2 SYSTEM DESCRIPTION1.2.1 General System DescriptionProvide central monitoring services, including associated facilities, equipment, appurtenances and trained personnel for the service of remotely monitoring alarm systems and taking actions as appropriate. The central monitori
18、ng facility shall be capable of monitoring security related alarm systems and shall be in compliance with UL 827, Central Station Alarm Services, and UL 2050, National Industrial Security Systems, for protection of National Security Information. The central monitoring facility shall be staffed and i
19、n operation at all times.1.2.2 Redundant Monitoring Facility*NOTE: A redundant monitoring facility is typically not necessary. Facilities meeting UL requirements, have redundancy on critical systems and are inherently reliable. However, requiring a redundant facility would allow signals to be rerout
20、ed in the event of a disaster at the primary monitoring facility with the break in the continuity of monitoring service being minimized. Requiring a redundant monitoring facility should be based on the importance of the protected site. Designer should confirm with the owner of the protected site as
21、to whether a redundant monitoring facility is required.Practices that are currently in use in the alarm industry would route alarm signals to a facility that is staffed and operating. Thus, it is unnecessary to permit an extensive break in the continuity of monitoring service. The designer should co
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYUFGS2820022008CENTRALMONITORINGSERVICESFORELECTRONICSECURITYSYSTEMS 电子 安全 系统 中央 监控 服务 PDF

链接地址:http://www.mydoc123.com/p-449673.html