1、*USACE / NAVFAC / AFCESA / NASA UFGS-23 82 01.00 10 (April 2008)-Preparing Activity: USACE SupersedingUFGS-23 82 01.00 10 (January 2008)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated March 2008*SECTION TABLE OF CONTENTSDIVISION 23 - HEATING, VENTILATING, AND AIR C
2、ONDITIONINGSECTION 23 82 01.00 10WARM AIR HEATING SYSTEMS04/08PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 QUALITY ASSURANCE1.3.1 Qualifications1.3.2 Electrical Work1.4 DELIVERY, STORAGE, AND HANDLING1.5 EXTRA MATERIALSPART 2 PRODUCTS2.1 MATERIALS AND EQUIPMENT2.1.1 Standard Products2.1.2 Nameplate
3、s2.2 SELF-CONTAINED FURNACE2.2.1 Gas-Fired Unit2.2.2 Oil-Fired Unit2.3 FURNACE COMPONENTS2.3.1 Oil-Burning Components2.3.2 Gas-Burning Components2.3.3 Ignition Systems2.3.3.1 Gas-Fired Units2.3.3.2 Oil-Fired Units2.3.4 Supply Blowers2.3.5 Vents for Conventional furnaces2.3.5.1 Gas-Fired Units2.3.5.2
4、 Oil-Fired Units2.3.6 Vents for High Efficiency Furnaces2.3.6.1 Combustion Air Intake Vent2.3.6.2 Exhaust Vent2.4 AIR CONDITIONING EQUIPMENT2.5 CONTROLS2.6 AUTOMATIC VENT DAMPERS2.7 HUMIDIFIERS2.7.1 Steam Spray TypeSECTION 23 82 01.00 10 Page 1Provided by IHSNot for ResaleNo reproduction or networki
5、ng permitted without license from IHS-,-,-2.7.2 Steam Diffuser Type2.7.3 Operation2.8 AIR FILTERS2.8.1 Replaceable Media filters2.8.2 Sectional Cleanable Filters2.9 FUEL-OIL SYSTEMS2.10 FUEL-GAS SUPPLY SYSTEM2.11 DUCTWORK COMPONENTS2.11.1 Metal Ductwork2.11.1.1 Transitions2.11.1.2 Insulated Nonmetal
6、lic Flexible Duct Runouts2.11.1.3 General Service Duct Connectors2.11.2 Fibrous Glass Ductwork2.11.3 Ductwork Accessories2.11.3.1 Duct Access Doors2.11.3.2 Fire Dampers2.11.3.3 Splitters and Manual Balancing Dampers2.11.3.4 Air Deflectors and Branch Connections2.11.4 Duct Sleeves, Framed Prepared Op
7、enings, Closure Collars2.11.4.1 Duct Sleeves2.11.4.2 Framed Prepared Opening2.11.4.3 Closure Collars2.11.5 Diffusers, Registers, and Grilles2.11.5.1 Diffusers2.11.5.2 Registers and Grilles2.11.6 Louvers2.12 FACTORY PAINTINGPART 3 EXECUTION3.1 EXAMINATION3.2 INSTALLATION3.2.1 Furnaces3.2.2 Automatic
8、Vent Dampers3.2.3 Humidifiers3.2.4 Access Panels3.2.5 Flexible Connectors3.2.6 Sleeved and Framed Openings3.2.7 Metal Ductwork3.2.8 Fibrous glass Ductwork3.2.9 Air Filters3.2.10 Dust Control3.2.11 Insulation3.2.12 Duct Test Holes3.2.13 Fuel-Oil System3.3 FIELD PAINTING3.4 CLEANING3.5 FIELD TRAINING3
9、.6 TESTS3.6.1 Ductwork Leak Test3.6.2 Testing, Adjusting, and Balancing3.6.3 Performance Tests- End of Section Table of Contents -SECTION 23 82 01.00 10 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-23 82
10、01.00 10 (April 2008)-Preparing Activity: USACE SupersedingUFGS-23 82 01.00 10 (January 2008)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated March 2008*SECTION 23 82 01.00 10WARM AIR HEATING SYSTEMS04/08*NOTE: This guide specification covers the requirements for wa
11、rm air heating systems used primarily in barracks, offices and other similar applications.Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and re
12、quirements not required in respective project, whether or not brackets are present.Comments and suggestions on this guide specification are welcome and should be directed to the technical proponent of the specification. A listing of technical proponents, including their organization designation and
13、telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).This guide specification includes tailoring options for gas fired unit, and oil fired unit. Selection or deselection of a tailoring option will include or exclude that option in
14、the section, but editing the resulting section to fit the project is still required.*PART 1 GENERAL*NOTE: Equipment listed in this section is not intended for family housing applications. Systems are for use primarily in barracks, offices and other similar applications.*SECTION 23 82 01.00 10 Page 3
15、Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in th
16、is paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update th
17、e issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications
18、are referred to within the text by the basic designation only.AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING ENGINEERS (ASHRAE)ASHRAE 52.1 (1992) Gravimetric and Dust-Spot Procedures for Testing Air-Cleaning Devices Used in General Ventilation for Removing Particulate MatterASTM INT
19、ERNATIONAL (ASTM)ASTM A 123/A 123M (2002) Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel ProductsASTM A 53/A 53M (2007) Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and SeamlessASTM A 653/A 653M (2007) Standard Specification for S
20、teel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip ProcessASTM B 117 (2007) Standing Practice for Operating Salt Spray (Fog) ApparatusASTM D 1654 (2005) Evaluation of Painted or Coated Specimens Subjected to Corrosive EnvironmentsASTM D 1784 (2007) Standard
21、Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and SECTION 23 82 01.00 10 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Chlorinated Poly(Vinyl Chloride) (CPVC) CompoundsASTM D 3359 (2002) Measuring Adhesion by Tape TestASTM D 52
22、0 (2000; R 2005) Zinc Dust PigmentCSA AMERICA, INC. (CSA/AM)CSA Directory (updated continuously online) Certified Products ListingsCSA/AM Z21.47 (2006; Addenda A 2007) Gas-Fired Central FurnacesCSA/AM Z21.66 (1996; R 2006) Automatic Vent Damper Devices for Use with Gas-Fired AppliancesNATIONAL ELECT
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。