ARMY UFGS-12 50 00-2009 FURNITURE SYSTEMS《家具系统》.pdf
《ARMY UFGS-12 50 00-2009 FURNITURE SYSTEMS《家具系统》.pdf》由会员分享,可在线阅读,更多相关《ARMY UFGS-12 50 00-2009 FURNITURE SYSTEMS《家具系统》.pdf(35页珍藏版)》请在麦多课文档分享上搜索。
1、USACE / NAVFAC / AFCESA / NASA UFGS-12 50 00 (February 2009)-Preparing Activity: USACE SupersedingUFGS-12 50 00 (January 2007)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated January 2009SECTION TABLE OF CONTENTSDIVISION 12 - FURNISHINGSSECTION 12 50 00FURNITURE SYS
2、TEMS02/09PART 1 GENERAL1.1 REFERENCES1.2 SYSTEM DESCRIPTION1.2.1 Workstations1.2.2 Samples1.2.3 Mock-up1.2.4 ALTERNATE DESIGN1.2.4.1 Component Requirements1.2.4.2 Wiring Configuration1.2.5 Sustainable Design1.2.5.1 Local/Regional Materials1.2.5.2 Environmental Data1.2.5.3 Certification1.2.6 Performa
3、nce Requirements1.2.6.1 Selected Components1.2.6.2 Panel Acoustics1.2.6.3 Panel Glazing1.2.7 Pattern and Color1.3 SUBMITTALS1.4 QUALITY ASSURANCE1.4.1 General Safety1.4.2 Fire Safety1.4.3 Electrical System1.4.4 Detail Drawings1.5 DELIVERY, STORAGE, AND HANDLING1.6 WARRANTY1.7 MAINTENANCE SERVICEPART
4、 2 PRODUCTS2.1 MATERIALS2.1.1 Metal2.1.2 Composite Wood and Fiberboard2.1.3 Remanufactured or Refurbished Furniture Systems2.1.4 PlasticSECTION 12 50 00 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.1.5 Fabric2.1.6 Linoleum2.1.7 Paints and
5、Coatings2.2 PANEL SYSTEM SPINE WALL SYSTEM DESK-BASED SYSTEMS2.2.1 Panel System2.2.2 Stacking Panel-Frame System2.2.3 Spine Wall System2.2.4 Desk-Based Systems2.2.5 Finishes2.2.6 Raceways2.2.7 Leveling Glides2.2.8 Connection System2.2.9 Wall Mounted Panels2.2.10 Glazed Panel Inserts2.2.11 Door Panel
6、s2.2.12 Sliding Doors2.3 WORK SURFACES2.3.1 General Requirements2.3.2 Finishes2.4 PEDESTALS2.4.1 Construction2.4.2 Finishes2.4.3 Drawer Requirements2.5 STORAGE CAPACITY2.5.1 Shelf Unit Construction2.5.2 Overhead Cabinet Construction2.5.3 Lateral File, Vertical File, Pedestal and Book Case Constructi
7、on2.5.4 Personal Storage Tower Construction2.5.5 Finish2.6 ACCESSORIES2.6.1 Coat Hook2.6.2 Keyboard Tray2.6.3 Computer Turntables2.6.4 Tackboards2.6.5 Erasable Marker Boards2.6.6 Paper Management Unit2.6.7 Wall Mounted Components2.6.8 CPU Holder2.6.9 Signage2.6.10 Slat Tile2.6.11 Monitor Arm2.7 MISC
8、ELLANEOUS HARDWARE2.8 LOCKS AND KEYING2.9 POWER AND COMMUNICATIONS2.9.1 Panel Raceways2.9.2 Spine Wall2.9.3 Power Distribution2.9.3.1 Receptacles2.9.3.2 Power Cabling Variations2.9.4 Electrical Connections2.9.4.1 Internal Connections2.9.4.2 Connections to Building Services2.9.5 Wire Management2.9.6
9、Circuit Layout2.9.7 Service Entry Poles2.9.8 Task Lighting2.9.8.1 Luminaire Configuration2.9.8.2 WiringSECTION 12 50 00 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.9.9 Communications2.9.10 Special SystemsPART 3 EXECUTION3.1 INSTALLATION3.
10、2 CLEANING3.3 WASTE MANAGEMENT- End of Section Table of Contents -SECTION 12 50 00 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-USACE / NAVFAC / AFCESA / NASA UFGS-12 50 00 (February 2009)-Preparing Activity: USACE SupersedingUFGS-12 50 00 (
11、January 2007)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated January 2009SECTION 12 50 00FURNITURE SYSTEMS02/09NOTE: This guide specification covers the requirements for furniture systems which include panel-supported, stackable panel, spine wall and desk-supported
12、 furniture systems.Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets
13、are present.Comments and suggestions on this guide specification are welcome and should be directed to the technical proponent of the specification. A listing of technical proponents, including their organization designation and telephone number, is on the Internet.Recommended changes to a UFGS shou
14、ld be submitted as a Criteria Change Request (CCR).This guide specification includes tailoring options for USACE and non-USACE. Selection or deselection of a tailoring option will include or exclude that option in the section, but editing the resulting section to fit the project is still required.PA
15、RT 1 GENERALNOTE: Various provisions of this guide specification may be irrelevant to or in conflict with the requirements of any given project. This spec should be carefully edited to fit the needs of each specific application. Portions must be deleted, if not applicable, and additional material in
16、serted where necessary to adequately delineate SECTION 12 50 00 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-requirements. Brackets and blanks identify provisions which involve alternates; the editor must select and/or insert the appropriate
17、 requirements.1.1 REFERENCESNOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards
18、Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this
19、 section of the project specification when you choose to reconcile references in the publish print process.The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.AMERICAN NATIONAL STANDA
20、RDS INSTITUTE (ANSI)ANSI Z97.1 (2004) Safety Glazing Materials Used in BuildingsASTM INTERNATIONAL (ASTM)ASTM C 1048 (2004) Standard Specification for Heat-Treated Flat Glass - Kind HS, Kind FT Coated and Uncoated GlassASTM C 423 (2008a) Sound Absorption and Sound Absorption Coefficients by the Reve
21、rberation Room MethodASTM D 1972 (1997; R 2005) Standard Practice for Generic Marking of Plastic ProductsASTM E 2129 (2005) Standard Practice for Data Collection for Sustainability Assessment of Building ProductsASTM E 290 (1997a; R 2004) Bend Testing of Material for DuctilityASTM E 84 (2008a) Stand
22、ard Test Method for Surface Burning Characteristics of Building SECTION 12 50 00 Page 5Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MaterialsBIFMA INTERNATIONAL (BIFMA)BIFMA X5.5 (1998) Desk ProductsBIFMA X5.6 (2003) Panel SystemsGREENGUARD ENVIRO
23、NMENTAL INSTITUTE (GEI)GEI Greenguard Standards for Low Emitting ProductsNATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)NEMA WD 1 (1999; R 2005) Standard for General Requirements for Wiring DevicesNEMA WD 6 (2002; R 2008) Standard for Wiring Devices - Dimensional RequirementsNATIONAL FIRE PROTE
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYUFGS1250002009FURNITURESYSTEMS 家具 系统 PDF
