ARMY UFGS-12 24 13-2010 ROLLER WINDOW SHADES《卷动遮光窗帘》.pdf
《ARMY UFGS-12 24 13-2010 ROLLER WINDOW SHADES《卷动遮光窗帘》.pdf》由会员分享,可在线阅读,更多相关《ARMY UFGS-12 24 13-2010 ROLLER WINDOW SHADES《卷动遮光窗帘》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-12 24 13 (August 2010)-Preparing Activity: USACE SupersedingUFGS-12 24 13 (February 2010)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2010*SECTION TABLE OF CONTENTSDIVISION 12 - FURNISHINGSSECTION 12 24 13ROLLER WINDOW S
2、HADES08/10PART 1 GENERAL1.1 GENERAL REQUIREMENTS1.2 REFERENCES1.3 SUBMITTALS1.4 QUALITY ASSURANCE1.4.1 Qualifications1.4.1.1 Manufacturers Qualifications1.4.1.2 Installers Qualifications1.4.2 Flammability Requirements1.4.3 Electrical Requirements1.4.4 Anti-Microbial Requirements1.4.5 Sustainable Des
3、ign Documentation1.4.6 Sustainable Design Certification1.5 DELIVERY, STORAGE, AND HANDLING1.6 WARRANTYPART 2 PRODUCTS2.1 WINDOW SHADES2.1.1 Light Filtering Shades2.1.2 Room Darkening Shades2.2 COLORPART 3 EXECUTION3.1 FIELD MEASUREMENTS3.2 ROLLER WINDOW SHADE PLACEMENT SCHEDULE3.3 INSTALLATION3.4 CL
4、EAN-UP- End of Section Table of Contents -SECTION 12 24 13 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-12 24 13 (August 2010)-Preparing Activity: USACE SupersedingUFGS-12 24 13 (February 2010)UNIFIED FAC
5、ILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2010*SECTION 12 24 13ROLLER WINDOW SHADES08/10*NOTE: This guide specification covers the requirements for roller window shades and hardware.Edit this guide specification for project specific requirements by adding, deleting
6、, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments and suggestions on this guide specification are welcome and should be directed to
7、 the technical proponent of the specification. A listing of technical proponents, including their organization designation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).PART 1 GENERAL*NOTE: Use Section 12 21 00 for WINDO
8、W BLINDS. Use Section 12 22 00 for CURTAINS AND DRAPES*1.1 GENERAL REQUIREMENTSProvide roller window shades, complete with necessary brackets, fittings, and hardware in accordance with paragraph ROLLER WINDOW SHADE PLACEMENT SCHEDULE as located in the drawings. Mount and operate equipment in accorda
9、nce with manufacturers instructions. Windows to receive a shade shall be completely covered.a. Submit drawings showing plans, elevations, sections, product details, installation details, operational clearances, wiring diagrams and relationship to adjacent work. Include the use of same room designati
10、ons as indicated on the drawings.SECTION 12 24 13 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-b. Provide manufacturers data composed of catalog cuts, brochures, product information, and operating and maintenance instructions on each product
11、 to be used. Include styles, profiles and features.c. Furnish samples of each type and color of roller shade fabric and roller shade channel. Shade material shall be minimum 150 by 150 mm6 by 6 inch in size. Mark face of material to indicate interior faces.d. Mock up: Install shade in area designate
12、d by Contracting Officer. Do not proceed with remaining work until the Contracting Officer approves workmanship and operation. Re-work mock-up as required to produce acceptable work. The approved shade can be used in installation.e. Submit fire resistance data, flame spread and smoke contribution da
13、ta.f. Provide LEED documentation relative to: local/regional materials (LEED) credit and recycled content credit in accordance with LEED Reference Guide. Include in LEED Documentation Notebook.1.2 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specifi
14、cation. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the referenc
15、e in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publicat
16、ions listed below form a part of this specification to the extent referenced. The publications are referred to in the text by basic designation only.ASTM INTERNATIONAL (ASTM)ASTM G 21 (1996; R 2002) Determining Resistance of Synthetic Polymeric Materials to FungiGREENGUARD ENVIRONMENTAL INSTITUTE (G
17、EI)GEI Greenguard Standards for Low Emitting ProductsSECTION 12 24 13 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)NFPA 701 (2010) Standard Methods of Fire Tests for Flame Propagation of Textiles an
18、d FilmsSCIENTIFIC CERTIFICATION SYSTEMS (SCS)SCS Scientific Certification Systems (SCS)Indoor AdvantageUNDERWRITERS LABORATORIES (UL)UL 325 (2002; R 2010) Door, Drapery, Gate, Louver, and Window Operators and Systems1.3 SUBMITTALS*NOTE: Review submittal description (SD) definitions in Section 01 33
19、00 SUBMITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project. Submittals should be kept to the minimum required for adequate quality control.A “G” following a submittal item indicates that the submittal requires Government approval. Some submittals are
20、already marked with a “G”. Only delete an existing “G” if the submittal item is not complex and can be reviewed through the Contractors Quality Control system. Only add a “G” if the submittal is sufficiently important or complex in context of the project.For submittals requiring Government approval
21、on Army projects, a code of up to three characters within the submittal tags may be used following the “G“ designation to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: “AE“ for Architect-Engineer; “DO“ for District Office (Engineering Divis
22、ion or other organization in the District Office); “AO“ for Area Office; “RO“ for Resident Office; and “PO“ for Project Office. Codes following the “G“ typically are not used for Navy, Air Force, and NASA projects.Choose the first bracketed item for Navy, Air Force and NASA projects, or choose the s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYUFGS1224132010ROLLERWINDOWSHADES 卷动 遮光 窗帘 PDF

链接地址:http://www.mydoc123.com/p-449622.html