ARMY UFGS-09 67 23 14-2010 CHEMICAL RESISTIVE RESINOUS FLOORING.pdf
《ARMY UFGS-09 67 23 14-2010 CHEMICAL RESISTIVE RESINOUS FLOORING.pdf》由会员分享,可在线阅读,更多相关《ARMY UFGS-09 67 23 14-2010 CHEMICAL RESISTIVE RESINOUS FLOORING.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-09 67 23.14 (August 2010)-Preparing Activity: USACE SupersedingUFGS-09 67 00 (April 2008)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2010*SECTION TABLE OF CONTENTSDIVISION 09 - FINISHESSECTION 09 67 23.14CHEMICAL RESIST
2、IVE RESINOUS FLOORING08/10PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 QUALITY ASSURANCE1.3.1 Qualifications of Installer1.3.2 Sustainable Design Certification1.4 DELIVERY, STORAGE, AND HANDLING1.5 ENVIRONMENTAL REQUIREMENTSPART 2 PRODUCTS2.1 MATERIALS2.1.1 Primer2.1.2 Aggregate2.1.3 Binder2.1.4 Fi
3、llers2.1.5 Top Coating2.2 FLOORING SYSTEMS2.2.1 Latex or Resinous Emulsion Matrix Floor Surfacing2.2.2 Epoxy Matrix Floor Surfacing2.2.3 Polyester Matrix Floor Surfacing2.3 CONDUCTIVE SPARKPROOF FLOORING2.4 SEALER AND RESIN2.5 ANTIMICROBIAL2.6 WALL BASE2.6.1 Resilient Base2.6.2 Self-Coving2.7 COLORP
4、ART 3 EXECUTION3.1 SURFACE PREPARATION3.1.1 Concrete Surfaces3.1.1.1 Mechanical Cleaning3.1.1.2 Steam CleaningSECTION 09 67 23.14 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.1.1.3 Paint Stripping3.1.1.4 Acid Etching3.1.1.5 Air Drying3.1.2
5、 Plywood3.1.3 Ceramic Tile3.1.4 Substrate Cracks, Spalls, Joints, and Depressions3.2 MIXING3.3 APPLICATION3.3.1 Primer3.3.2 Floor Surfacing3.3.3 Seal Coat3.4 TESTING3.4.1 Electrical Resistance3.4.2 Spark Resistance3.5 PROTECTION- End of Section Table of Contents -SECTION 09 67 23.14 Page 2Provided b
6、y IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-09 67 23.14 (August 2010)-Preparing Activity: USACE SupersedingUFGS-09 67 00 (April 2008)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated Jul
7、y 2010*SECTION 09 67 23.14CHEMICAL RESISTIVE RESINOUS FLOORING08/10*NOTE: This specification covers the requirements for trowelled-on industrial resinous flooring, conductive resinous flooring, and decorative resinous flooring except resinous terrazzo.Edit this guide specification for project specif
8、ic requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments and suggestions on this guide specification ar
9、e welcome and should be directed to the technical proponent of the specification. A listing of technical proponents, including their organization designation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).*PART 1 GENERAL*
10、NOTE: The floor systems covered by this guide specification are primarily intended for use in biological laboratories, in similar areas which are subject to hard wear or spillage of chemicals and require a high degree of cleanliness, and for explosive and ammunition facilities.These systems are for
11、use over normal weight concrete and will not be used over lightweight concrete. The selection of a floor system for a location where resistance to specific chemical conditions is important should be based upon the ability of the system to withstand required exposure SECTION 09 67 23.14 Page 3Provide
12、d by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-conditions. For example, polyesters are suitable for use where resistance to detergents is required but should not be used in laboratory or other areas where spillage of sodium hydroxide or similar strong alka
13、line solution occurs; epoxies should not be used where resistance to oxidizing acids is required or where resistance to temperatures in excess of 54 degrees C (130 degrees F) is required. Each job should be evaluated on its own merits considering exposure conditions, costs, flammability of materials
14、, and local experience with the various systems. All provisions relating to the systems not selected will be deleted.Check other sections of the specifications to ensure:1. No vermiculite or perlite aggregates in concrete substrates.2. No curing compounds or sealers on concrete substrates.3. New con
15、crete receives single trowelled finish; and no burnished finishes.4. Vapor barrier is provided under all concrete slabs-on-grade.5. Only exterior grade plywood on new plywood substrates. No interior grade or interior grade with exterior glue. Plywood is nailed with annular ring or spiral nails only.
16、6. No dimension lumber substrate in new construction; when existing lumber substrates are to be covered, overlay with 50 by 50 mm (2 by 2 inch) mesh hardware cloth.On the drawings, show:1. Location of resinous flooring. If more than one type is to be used, key each to location on the drawings.2. Det
17、ails of special items such as coved bases, expansion joints, control joints, stairs, and floor drains.3. Details for grounding of conductive floors.*1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in
18、the text by basic designation only and listed in this paragraph by organization, designation, date, SECTION 09 67 23.14 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-and title.Use the Reference Wizards Check Reference feature when you add a R
19、ID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification wh
20、en you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.ACI INTERNATIONAL (ACI)ACI 503R (1993; R 2008) Use of Epoxy Com
21、pounds with ConcreteASTM INTERNATIONAL (ASTM)ASTM C 307 (2003; R 2008) Tensile Strength of Chemical-Resistant Mortar, Grouts, and Monolithic SurfacingsASTM C 413 (2001; R 2006) Absorption of Chemical-Resistant Mortars, Grouts, and Monolithic Surfacings and Polymer ConcretesASTM C 531 (2000; R 2005)
22、Linear Shrinkage and Coefficient of Thermal Expansion of Chemical-Resistant Mortars, Grouts, and Monolithic Surfacings, and Polymer ConcretesASTM C 579 (2001; R 2006) Compressive Strength of Chemical-Resistant Mortars, Grouts, Monolithic Surfacings, and Polymer ConcretesASTM C 580 (2002; R 2008) Fle
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYUFGS096723142010CHEMICALRESISTIVERESINOUSFLOORINGPDF

链接地址:http://www.mydoc123.com/p-449600.html