1、*USACE / NAVFAC / AFCESA / NASA UFGS-09 66 23 (August 2010)-Preparing Activity: USACE SupersedingUFGS-09 66 23 (May 2009)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2010*SECTION TABLE OF CONTENTSDIVISION 09 - FINISHESSECTION 09 66 23RESINOUS TERRAZZO FLOOR
2、ING08/10PART 1 GENERAL1.1 REFERENCES1.2 SYSTEM DESCRIPTION1.3 SUBMITTALS1.4 QUALITY ASSURANCE1.4.1 Applicator1.4.2 Sustainable Design Certification1.5 DELIVERY, STORAGE, AND HANDLING1.6 ENVIRONMENTAL REQUIREMENTSPART 2 PRODUCTS2.1 PRIMER2.2 RESIN2.3 FILLERS2.4 MARBLE CHIPS2.5 STRIPS2.5.1 Divider Str
3、ips2.5.2 Control Joint Strips2.6 GROUT2.7 SEALERPART 3 EXECUTION3.1 PREPARATION OF CONCRETE SUBFLOOR3.2 MIXING, PROPORTIONING, AND INSTALLATION3.3 TESTING3.4 CLEANING AND SEALING3.5 PROTECTION- End of Section Table of Contents -SECTION 09 66 23 Page 1Provided by IHSNot for ResaleNo reproduction or n
4、etworking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-09 66 23 (August 2010)-Preparing Activity: USACE SupersedingUFGS-09 66 23 (May 2009)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2010*SECTION 09 66 23RESINOUS TERRAZZO FLO
5、ORING08/10*NOTE: This guide specification covers the requirements for resinous terrazzo flooring and conductive resinous terrazzo flooring.Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert
6、appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments and suggestions on this guide specification are welcome and should be directed to the technical proponent of the specification. A listing of technical proponen
7、ts, including their organization designation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).*PART 1 GENERAL*NOTE: The resinous terrazzo floor systems covered by this guide specification may be used in lieu of portland cem
8、ent terrazzo where the light weight of the thin set system would be advantageous.The conductive resinous terrazzo flooring is primarily intended for use in areas where volatile materials are handled, clean-rooms, parachute assembly areas, etc. These systems, which have a wear factor four times bette
9、r than cementitious terrazzo and five to six times better than vinyl may be used, when economically justified, in hard wear areas where there is a need for a high degree of cleanliness, a decorative effect, and some chemical resistance. These systems will not be used over SECTION 09 66 23 Page 2Prov
10、ided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-lightweight concrete and will not be used in lieu of quarry tile in kitchens.The selection of a floor system for a location where resistance to specific conditions is important should be based upon the abil
11、ity of the system to withstand required exposure conditions. For example, polyesters are suitable where resistance to detergents is required but should not be used in laboratory or other areas where spillage of sodium hydroxide or similar strong alkaline solution occurs; epoxies should not be used w
12、here resistance to oxidizing acids is required or where resistance to temperatures in excess of 54 degrees C (130 degrees F) is required; latex mastic and resin emulsions should not be used where resistance to strong acids or alkalis is required. Each job should be evaluated on its own merits consid
13、ering exposure conditions, costs, and local experience with the various systems.Areas to receive terrazzo will be shown on the drawings. Color should be shown by specifying a selected plate number from the NTMA publication, “Terrazzo Information Guide.“ Example: NTMA terrazzo catalog, plate No. S-30
14、1-4. Colors selected may be any combination of standard marble granules of domestic origin available in the local market, but it is highly desirable that color combinations be designated by NTMA color plates.*1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of t
15、he guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically pl
16、ace the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print proce
17、ss.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.SECTION 09 66 23 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-ASTM I
18、NTERNATIONAL (ASTM)ASTM D 56 (2005) Flash Point by Tag Closed Cup TesterGREENGUARD ENVIRONMENTAL INSTITUTE (GEI)GEI Greenguard Standards for Low Emitting ProductsNATIONAL FIRE PROTECTION ASSOCIATION (NFPA)NFPA 99 (2005; TIA 05-1; TIA 05-2; TIA 05-3) Standard for Health Care FacilitiesNATIONAL TERRAZ
19、ZO “DO“ for District Office (Engineering Division or other organization in the District Office); “AO“ for Area Office; “RO“ for Resident Office; and “PO“ for Project Office. Codes following the “G“ typically are not used for Navy, Air Force, and NASA projects.Choose the first bracketed item for Navy
20、, Air Force and NASA projects, or choose the second bracketed item for Army projects.*Government approval is required for submittals with a “G“ designation; submittals not having a “G“ designation are for Contractor Quality Control approval. information only. When used, a designation following the “
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYUFGS0966232010RESINOUSTERRAZZOFLOORINGPDF

链接地址:http://www.mydoc123.com/p-449599.html