ARMY UFGS-09 66 16-2010 TERRAZZO TILE.pdf
《ARMY UFGS-09 66 16-2010 TERRAZZO TILE.pdf》由会员分享,可在线阅读,更多相关《ARMY UFGS-09 66 16-2010 TERRAZZO TILE.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-09 66 16 (August 2010)-Preparing Activity: USACE SupersedingUFGS-09 66 16 (May 2009)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2010*SECTION TABLE OF CONTENTSDIVISION 09 - FINISHESSECTION 09 66 16TERRAZZO TILE08/10PART
2、1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 QUALITY ASSURANCE1.3.1 Installer Qualification1.3.2 Sustainable Design Certification1.4 DELIVERY, STORAGE, AND HANDLING1.5 SITE CONDITIONS1.6 WARRANTYPART 2 PRODUCTS2.1 STANDARD PRODUCTS2.2 TERRAZZO TILE2.3 ADHESIVE2.4 RESILIENT BASE2.5 TERRAZZO BASE/STRIPS2.
3、6 METAL EDGE STRIPS2.7 COLORPART 3 EXECUTION3.1 EXAMINATION3.2 GENERAL3.3 SUBSTRATE PREPARATION3.4 INSTALLATION3.4.1 Tile3.4.2 Metal Edge Strips3.4.3 Terrazzo Base/Strips3.4.4 Base3.5 MOISTURE TEST3.6 CLEANING3.7 PROTECTION- End of Section Table of Contents -SECTION 09 66 16 Page 1Provided by IHSNot
4、 for ResaleNo reproduction or networking permitted without license from IHS-,-,-SECTION 09 66 16 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-09 66 16 (August 2010)-Preparing Activity: USACE SupersedingUF
5、GS-09 66 16 (May 2009)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2010*SECTION 09 66 16TERRAZZO TILE08/10*NOTE: This guide specification covers the requirements for cast marble or granite terrazzo tile of various sizes and thicknesses).Edit this guide spec
6、ification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments and suggestions on
7、 this guide specification are welcome and should be directed to the technical proponent of the specification. A listing of technical proponents, including their organization designation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Re
8、quest (CCR).*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Refe
9、rence Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update SECTION 09 66 16 Page 3Provided by IHSNot for ResaleNo reproduction or ne
10、tworking permitted without license from IHS-,-,-the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specifi
11、cation to the extent referenced. The publications are referred to within the text by the basic designation only.ASTM INTERNATIONAL (ASTM)ASTM C 109/C 109M (2008) Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or (50-mm) Cube Specimens)ASTM C 501 (1984; R 2009)
12、 Relative Resistance to Wear of Unglazed Ceramic Tile by the Taber AbraserASTM C 97/C 97M (2009) Absorption and Bulk Specific Gravity of Dimension StoneASTM D 2047 (2004) Static Coefficient of Friction of Polish-Coated Floor Surfaces as Measured by the James MachineASTM E 648 (2009a) Standard Test M
13、ethod for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy SourceASTM E 84 (2010) Standard Test Method for Surface Burning Characteristics of Building MaterialsGREENGUARD ENVIRONMENTAL INSTITUTE (GEI)GEI Greenguard Standards for Low Emitting ProductsSCIENTIFIC CERTIFICATIO
14、N SYSTEMS (SCS)SCS Scientific Certification Systems (SCS)Indoor Advantage1.2 SUBMITTALS*NOTE: Review submittal description (SD) definitions in Section 01 33 00 SUBMITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project. Submittals should be kept to the m
15、inimum required for adequate quality control.A “G” following a submittal item indicates that the submittal requires Government approval. Some SECTION 09 66 16 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-submittals are already marked with a
16、“G”. Only delete an existing “G” if the submittal item is not complex and can be reviewed through the Contractors Quality Control system. Only add a “G” if the submittal is sufficiently important or complex in context of the project.For submittals requiring Government approval on Army projects, a co
17、de of up to three characters within the submittal tags may be used following the “G“ designation to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: “AE“ for Architect-Engineer; “DO“ for District Office (Engineering Division or other organizat
18、ion in the District Office); “AO“ for Area Office; “RO“ for Resident Office; and “PO“ for Project Office. Codes following the “G“ typically are not used for Navy, Air Force, and NASA projects.Choose the first bracketed item for Navy, Air Force and NASA projects, or choose the second bracketed item f
19、or Army projects.*Government approval is required for submittals with a “G“ designation; submittals not having a “G“ designation are for Contractor Quality Control approval. information only. When used, a designation following the “G“ designation identifies the office that will review the submittal
20、for the Government. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:SD-02 Shop DrawingsTerrazzo Tile; G; G, _SD-03 Product DataInstallationCertificationSD-04 SamplesTerrazzo TileResilient BaseTerrazzo Base/StripsMetal Edge StripsSD-07 CertificatesTerrazzo TileAdhesiveRe
21、silient BaseSD-10 Operation and Maintenance DataManufacturers Maintenance InstructionsSECTION 09 66 16 Page 5Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-1.3 QUALITY ASSURANCE1.3.1 Installer QualificationInstaller shall possess, to the satisfactio
22、n of the Contracting Officer, the technical qualifications, experience, trained personnel, and facilities to properly install the specified items.1.3.2 Sustainable Design CertificationProduct shall be third party certified by GEI Greenguard Indoor Air Quality Certified, SCS Scientific Certification
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYUFGS0966162010TERRAZZOTILEPDF