ARMY UFGS-09 64 29-2010 WOOD STRIP FLOORING.pdf
《ARMY UFGS-09 64 29-2010 WOOD STRIP FLOORING.pdf》由会员分享,可在线阅读,更多相关《ARMY UFGS-09 64 29-2010 WOOD STRIP FLOORING.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-09 64 29 (August 2010)-Preparing Activity: USACE SupersedingUFGS-09 64 29 (October 2006)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2010*SECTION TABLE OF CONTENTSDIVISION 09 - FINISHESSECTION 09 64 29WOOD STRIP FLOORING
2、08/10PART 1 GENERAL1.1 REFERENCES1.2 SYSTEM DESCRIPTION1.2.1 Sustainable Design Requirements1.2.1.1 Local/Regional Materials1.2.1.2 Environmental Data1.2.2 Forest Stewardship Council (FSC) Certification1.2.3 Sustainable Design Certification1.3 SUBMITTALS1.4 DELIVERY, STORAGE, AND HANDLING1.5 ENVIRON
3、MENTAL REQUIREMENTS1.6 SCHEDULINGPART 2 PRODUCTS2.1 STRIP FLOORING2.1.1 General Requirements2.1.2 Bamboo2.2 NAILS2.3 RESILIENT PADS2.4 WALL BASE2.5 MOISTURE BARRIER2.6 CLIPS, ANCHOR CHANNELS AND INSULATIONPART 3 EXECUTION3.1 SURFACE CONDITIONS3.2 INSTALLATION3.2.1 Gymnasium Floors3.2.1.1 Wood Sleepe
4、rs3.2.1.2 Steel Channels3.2.2 Handball Court Floor and Walls3.2.3 Squash and Handball Court Walls3.2.3.1 Wood Supports3.2.3.2 Steel SupportsSECTION 09 64 29 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.3 SANDING3.4 PROTECTION- End of Secti
5、on Table of Contents -SECTION 09 64 29 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-09 64 29 (August 2010)-Preparing Activity: USACE SupersedingUFGS-09 64 29 (October 2006)UNIFIED FACILITIES GUIDE SPECIFI
6、CATIONSReferences are in agreement with UMRL dated July 2010*SECTION 09 64 29WOOD STRIP FLOORING08/10*NOTE: This guide specification covers the requirements for wood strip flooring for gymnasiums, handball and squash courts, and other special purpose applications.Edit this guide specification for pr
7、oject specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments and suggestions on this guide spec
8、ification are welcome and should be directed to the technical proponent of the specification. A listing of technical proponents, including their organization designation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).*PAR
9、T 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Ch
10、eck Reference feature when you add a RID outside of the Sections Reference Article to automatically place the SECTION 09 64 29 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-reference in the Reference Article. Also use the Reference Wizards Ch
11、eck Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the ex
12、tent referenced. The publications are referred to within the text by the basic designation only.ASTM INTERNATIONAL (ASTM)ASTM E 2129 (2005) Standard Practice for Data Collection for Sustainability Assessment of Building ProductsFOREST STEWARDSHIP COUNCIL (FSC)FSC STD 01 001 (2000) Principles and Cri
13、teria for Forest StewardshipGREENGUARD ENVIRONMENTAL INSTITUTE (GEI)GEI Greenguard Standards for Low Emitting ProductsMAPLE FLOORING MANUFACTURERS ASSOCIATION (MFMA)MFMA GS (1999) Guide Specifications for Maple Flooring SystemsNOFMA: THE WOOD FLOORING MANUFACTURERS ASSOCIATION (NOFMA)NOFMA Grading R
14、ules (1999) Official Flooring Grading RulesSCIENTIFIC CERTIFICATION SYSTEMS (SCS)SCS Scientific Certification Systems (SCS)Indoor AdvantageU.S. GREEN BUILDING COUNCIL (USGBC)LEED (2002; R 2005) Leadership in Energy and Environmental Design(tm) Green Building Rating System for New Construction (LEED-
15、NC)1.2 SYSTEM DESCRIPTION*NOTE: Wood strip flooring is very sensitive to ambient humidity conditions since all wood flooring will expand and contract as relative humidity varies. In order to keep the flooring manufacturers warranty valid after installation, SECTION 09 64 29 Page 4Provided by IHSNot
16、for ResaleNo reproduction or networking permitted without license from IHS-,-,-the areas in which the wood floors are installed must be adequately ventilated with natural or mechanical air circulation at all times during the life of the flooring.If prior experience at the site indicates that relativ
17、e humidity during sustained heating periods will fall below 35 percent, the office in charge of building maintenance should provide equipment to introduce moisture into the floored area when required; conversely, if relative humidity increases to 50 percent or higher at any time, measures should be
18、taken to dry the floored area, including turning on the heat.At sites with humidity problems, the maintenance of the flooring may require: 1) The design of a localized HVAC system to also react to and automatically control ambient humidity conditions through the life of the flooring; or 2) Continuou
19、s monitoring of relative humidity with on the spot corrective actions, as needed, without altering the HVAC system. These alternatives could be very expensive or impractical. The designer, in the absence of local experience, should coordinate with local manufacturers to specify compatible floorings
20、which have performed well locally; that is, the designer should check gymnasiums in the area when building a gymnasium floor; the same for handball courts, etc. Of course, the designer has the option of purchasing commercially available floating or sleeper systems specifically designed to reduce the
21、 possibility of buckling and cupping brought on by moisture buildup or specifying other types of flooring when a cost analysis (including all HVAC variations) indicates that wood strip flooring is not economical.*This specification is written to allow the Contractor to build wood strip floorings for
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYUFGS0964292010WOODSTRIPFLOORINGPDF