ARMY UFGS-09 62 38-2012 STATIC-CONTROL FLOORING.pdf
《ARMY UFGS-09 62 38-2012 STATIC-CONTROL FLOORING.pdf》由会员分享,可在线阅读,更多相关《ARMY UFGS-09 62 38-2012 STATIC-CONTROL FLOORING.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-09 62 38 (November 2012)-Preparing Activity: USACE SupersedingUFGS-09 65 36 (November 2010)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated October 2012*SECTION TABLE OF CONTENTSDIVISION 09 - FINISHESSECTION 09 62 38STATIC-CONTRO
2、L FLOORING11/12PART 1 GENERAL1.1 REFERENCES1.2 SCHEDULING1.3 SUSTAINABILITIY REQUIREMENTS1.4 SUBMITTALS1.5 OTHER SUSTAINABLE REQUIREMENTS1.6 ENVIRONMENTAL DATA1.7 FIRE RESISTANCE TESTING REQUIREMENTS1.8 EXTRA MATERIALS1.9 QUALITY ASSURANCE1.10 DELIVERY, STORAGE, AND HANDLING1.10.1 Static-Control Res
3、ilient Flooring1.10.2 Static-Control Carpet1.11 ENVIRONMENTAL CONDITIONS1.11.1 Static-Control Resilient Flooring1.11.2 Static Control Carpet1.12 WARRANTY1.12.1 Static-Control Resilient Flooring1.12.2 Static-Control CarpetPART 2 PRODUCTS2.1 STATIC-CONTROL FLOORING AND ACCESSORIES2.1.1 Product Data2.1
4、.2 Samples2.1.3 Certificates2.1.4 Manufacturers Instructions2.1.5 Operations and Maintenance Data2.2 STATIC-CONTROL RESILIENT FLOORING2.2.1 Conductive Resilient Flooring2.2.1.1 Conductive Vinyl Tile2.2.1.2 Conductive Rubber Tile2.2.1.3 Conductive Rubber Sheet Flooring2.2.2 Static-Dissipative Resilie
5、nt Flooring2.2.2.1 Static-Dissipative Vinyl TileSECTION 09 62 38 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.2.2.2 Static-Dissipative Rubber Tile2.3 STATIC-CONTROL CARPET2.3.1 Physical Characteristics2.3.2 Static-Control Carpet Performanc
6、e Requirements2.4 WALL BASE2.4.1 Resilient Base2.4.2 Self-Coving2.5 ADHESIVES2.6 MOLDINGS2.7 ACCESSORIES2.8 ELECTRICAL GROUND CONNECTION2.9 MANUFACTURERS COLOR, PATTERN AND TEXTUREPART 3 EXECUTION3.1 SURFACE PREPARATION3.2 MOISTURE, ALKALINITY AND BOND TESTS3.3 INSTALLATION OF STATIC-CONTROL RESILIE
7、NT TILE FLOORING3.4 INSTALLATION OF STATIC-CONTROL RESILIENT SHEET FLOORING3.5 INSTALLATION OF STATIC-CONTROL CARPET3.6 INSTALLATION OF WALL BASE3.6.1 Resilient Base3.6.2 Self-Coving3.7 CLEANING AND PROTECTION3.8 TESTING- End of Section Table of Contents -SECTION 09 62 38 Page 2Provided by IHSNot fo
8、r ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-09 62 38 (November 2012)-Preparing Activity: USACE SupersedingUFGS-09 65 36 (November 2010)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated October 2012
9、*SECTION 09 62 38STATIC-CONTROL FLOORING11/12*NOTE: This guide specification covers the requirements for static-control resilient flooring over a concrete surface and static-control carpet over concrete or access flooring.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format S
10、tandard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information a
11、nd requirements not required in respective project, whether or not brackets are present.Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR).*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list
12、 the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sectio
13、ns Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update SECTION 09 62 38 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-the issue dates.References not
14、 used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the t
15、ext by the basic designation only.AMERICAN ASSOCIATION OF TEXTILE CHEMISTS AND COLORISTS (AATCC)AATCC TM 107 (2009; E 2010) Colorfastness to WaterAATCC TM 16 (2004; E 2010) Colorfastness to LightAATCC TM 165 (2008; E 2011) Colorfastness to Crocking: Textile Floor Coverings - Crockmeter MethodASTM IN
16、TERNATIONAL (ASTM)ASTM D5793 (2005) Binding Sites Per Unit Length or Width of Pile Yarn Floor CoveringsASTM D5848 (2010e1) Mass Per Unit Area of Pile Yarn Floor CoveringsASTM D6859 (2011) Standard Test Method for Pile Thickness of Finished Level Pile Yarn Floor CoveringsASTM E2129 (2010) Standard Pr
17、actice for Data Collection for Sustainability Assessment of Building ProductsASTM E648 (2010e1) Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy SourceASTM F1344 (2012) Rubber Floor TileASTM F150 (2006) Electrical Resistance of Conductive and Stati
18、c Dissipative Resilient FlooringASTM F1700 (2004; R 2010) Solid Vinyl Floor TileASTM F1859 (2012) Rubber Sheet Floor Covering Without BackingASTM F1861 (2008) Resilient Wall BaseASTM F1869 (2011) Measuring Moisture Vapor Emission Rate of Concrete Subfloor Using Anhydrous Calcium ChlorideASTM F2170 (
19、2011) Determining Relative Humidity in SECTION 09 62 38 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Concrete Floor Slabs in situ ProbesCARPET AND RUG INSTITUTE (CRI)CRI 104 (2002) Standard for Installation Specification of Commercial Carpet
20、ELECTROSTATIC DISCHARGE ASSOCIATION (ESD)ESD S6.1 (2009) GroundingESD S7.1 (2005) Floor Materials Characterization of MaterialsGREEN SEAL (GS)GS-36 (2000) Commercial AdhesivesINTERNATIONAL ORGANIZATION FOR STANDARDIZATION (ISO)ISO 2551 (1981) Machine-made Textile Floor Coverings - Determination of D
21、imensional Changes Due to the Effects of Varied Water and Heat ConditionsNATIONAL FIRE PROTECTION ASSOCIATION (NFPA)NFPA 99 (2012; TIA 11-1; TIA 11-2; Errata 12-1) Health Care Facilities CodeSOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD)SCAQMD Rule 1168 (1989; R 2005) Adhesive and Sealant Appl
22、icationsU.S. GREEN BUILDING COUNCIL (USGBC)LEED NC (2009) Leadership in Energy and Environmental Design(tm) New Construction Rating System1.2 SCHEDULINGSchedule static-control flooring work after any other work which would damage the finished surface of the flooring.1.3 SUSTAINABILITIY REQUIREMENTS*
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYUFGS0962382012STATICCONTROLFLOORINGPDF